Samsung AR12HSFNCWKXET manual ErP InformationAC Product, AR12HSFNCWKN / AR12HSFNCWKX

Page 1

ErP Information(AC Product)

 

 

 

 

AR12HSFNCWKN / AR12HSFNCWKX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

 

 

cooling

 

Y

 

Average

 

 

Y

 

 

heating

 

Y

 

Warmer

 

 

N

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

 

Design load

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Pdesignc

3,5

 

kW

cooling

SEER

 

5,6

 

-

 

heating/Average

 

Pdesignh

2,4

 

kW

heating/Average

SCOP/A

 

4,0

 

-

 

heating/Warmer

 

Pdesignh

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

 

heating/Colder

 

Pdesignh

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

 

Declared capacity(*) for

cooling, at indoor temperature

 

Declared energy efficiency ratio(*), at indoor temperature

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

 

Tj = 35 ℃

 

Pdc

3,5

 

kW

Tj = 35 ℃

EERd

 

3,1

 

-

 

Tj = 30 ℃

 

Pdc

2,6

 

kW

Tj = 30 ℃

EERd

 

4,2

 

-

 

Tj = 25 ℃

 

Pdc

1,7

 

kW

Tj = 25 ℃

EERd

 

7,4

 

-

 

Tj = 20 ℃

 

Pdc

1,2

 

kW

Tj = 20 ℃

EERd

 

9,0

 

-

 

Declared capacity(*) for

heating/Average

season, at

indoor

 

Declared coefficient of

performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = - 7 ℃

 

Pdh

2,1

 

kW

Tj = -7

COPd

 

2,4

 

-

 

Tj = 2 ℃

 

Pdh

1,3

 

kW

Tj = 2 ℃

COPd

 

3,9

 

-

 

Tj = 7 ℃

 

Pdh

0,9

 

kW

Tj = 7 ℃

COPd

 

5,4

 

-

 

Tj = 12 ℃

 

Pdh

0,2

 

kW

Tj = 12 ℃

COPd

 

6,7

 

-

 

Tj = bivalent

 

Pdh

2,4

 

kW

Tj = bivalent

COPd

 

2,2

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

2,4

 

kW

Tj = operating limit

COPd

 

2,2

 

-

 

Declared capacity(*) for

heating/Warmer

season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = 2 ℃

 

Pdh

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

 

Tj = 7 ℃

 

Pdh

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

 

Tj = 12 ℃

 

Pdh

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

 

Tj = bivalent

 

Pdh

-

 

kW

Tj = bivalent

COPd

 

-

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

-

 

kW

Tj = operating limit

COPd

 

-

 

-

 

Declared capacity(*) for

heating/Colder

season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = -7

 

Pdh

-

 

kW

Tj = -7

COPd

 

-

 

-

 

Tj = 2 ℃

 

Pdh

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

 

Tj = 7 ℃

 

Pdh

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

 

Tj = 12 ℃

 

Pdh

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

 

Tj = bivalent

 

Pdh

-

 

kW

Tj = bivalent

COPd

 

-

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

-

 

kW

Tj = operating limit

COPd

 

-

 

-

 

Tj = -15

 

Pdh

-

 

kW

Tj = -15

COPd

 

-

 

-

 

Bivalent temperature

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

 

Tbiv

-10

 

heating/Average

Tol

 

-10

 

 

heating/Warmer

 

Tbiv

-

 

heating/Warmer

Tol

 

-

 

 

heating/Colder

 

Tbiv

-

 

heating/Colder

Tol

 

-

 

 

Cycling interval capacity

 

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

 

Pcycc

-

 

kW

for cooling

EERcyc

 

-

 

-

 

for heating

 

Pcych

-

 

kW

for heating

COPcyc

 

-

 

-

 

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

 

co-efficient

 

Cdc

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

 

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

 

Electric power input in

power modes

other than

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

 

POFF

0,0

 

kW

cooling

QCE

 

219

 

kWh/a

 

standby mode

 

PSB

0,0

 

kW

heating/Average

QHE

 

840

 

kWh/a

 

thermostat-off mode

 

PTO

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

 

crankcase heater

 

PCK

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

56,0/62,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

480/1920

 

m3/h

 

 

 

(indoor/outdoor)

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

 

 

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents AR12HSFNCWKN / AR12HSFNCWKX ErP InformationAC ProductAccording to Commission Regulation EU No 206/2012
Related manuals
Manual 33 pages 13.52 Kb Manual 33 pages 44.92 Kb Manual 33 pages 33.49 Kb Manual 1 pages 46.73 Kb Manual 33 pages 46.75 Kb Manual 33 pages 60.77 Kb Manual 33 pages 41.46 Kb Manual 33 pages 37.98 Kb Manual 33 pages 31.06 Kb Manual 33 pages 55.13 Kb Manual 33 pages 53.07 Kb Manual 33 pages 8.6 Kb Manual 33 pages 19.96 Kb Manual 33 pages 18.78 Kb

AR12HSFNCWKXET, AR12HSFNCWKXZE, AR12HSFNCWKNET, AR12HSFNCWKNZE specifications

The Samsung AR09HSFNBWKNET, AR09HSFNCWKNZE, AR12HSFNCWKNZE, AR12HSFNBWKNET, and AR12HSFSAWKNZE models represent a robust lineup of air conditioning units designed to enhance indoor air quality while ensuring energy efficiency and user comfort.

One of the key features of these models is their energy efficiency. They come equipped with advanced inverter technology, which optimizes cooling performance while consuming less power. This technology allows the compressor to adjust its speed according to the temperature requirements of the room, significantly reducing electricity bills over time. These models often carry high energy efficiency ratings, making them suitable for eco-conscious consumers.

The Samsung air conditioners also provide superior cooling capabilities. With a quick cooling feature, they can rapidly lower the temperature in a room, ensuring immediate comfort during hot weather. The precise temperature control offered by these models enhances their ability to maintain a comfortable living environment.

Another notable characteristic is the air purification technology integrated into these units. They often include a multi-stage filtration system that effectively eliminates dust, allergens, and pollutants from the air. This ensures that the air quality in your space remains clean and healthy, catering especially to allergy sufferers and families with children.

User convenience is also at the forefront of these models. The inclusion of Wi-Fi connectivity allows users to control their air conditioning units remotely through a smartphone app. This feature not only enables scheduling and temperature adjustments from anywhere but also supports smart home integration for seamless operation.

Additionally, the sleek and modern design of these air conditioners enhances the aesthetic appeal of any indoor space. Their quiet operation ensures minimal disruption, making them ideal for bedrooms, living rooms, and offices alike.

Maintenance is made easy with user-friendly features, such as self-diagnosis capabilities that alert users to potential issues. Many models also feature removable and washable filters, simplifying routine upkeep and ensuring optimal performance.

Overall, the Samsung AR09HSFNBWKNET, AR09HSFNCWKNZE, AR12HSFNCWKNZE, AR12HSFNBWKNET, and AR12HSFSAWKNZE air conditioners are a comprehensive choice for consumers seeking efficient, stylish, and technologically advanced cooling solutions for their homes or offices. Their blend of innovative technology, energy efficiency, and user-centric features makes them excellent investments for maintaining comfort throughout the year.