Samsung AR18FSSKABEXEU manual ErP InformationAC Product

Page 1

ErP Information(AC Product)

 

 

 

 

 

 

AR18FSSEDWUN / AR18FSSEDWUX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

N

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

5,0

 

kW

cooling

SEER

 

6,1

 

-

heating/Average

Pdesignh

 

4,5

 

kW

heating/Average

SCOP/A

 

3,8

 

-

heating/Warmer

Pdesignh

 

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

5,0

 

kW

Tj = 35 ℃

EERd

 

2,9

 

-

Tj = 30 ℃

Pdc

 

3,8

 

kW

Tj = 30 ℃

EERd

 

4,4

 

-

Tj = 25 ℃

Pdc

 

2,5

 

kW

Tj = 25 ℃

EERd

 

7,2

 

-

Tj = 20 ℃

Pdc

 

1,7

 

kW

Tj = 20 ℃

EERd

 

12,7

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

4,1

 

kW

Tj = -7

COPd

 

2,4

 

-

Tj = 2 ℃

Pdh

 

2,6

 

kW

Tj = 2 ℃

COPd

 

3,8

 

-

Tj = 7 ℃

Pdh

 

1,6

 

kW

Tj = 7 ℃

COPd

 

4,8

 

-

Tj = 12 ℃

Pdh

 

1,3

 

kW

Tj = 12 ℃

COPd

 

6,0

 

-

Tj = bivalent

Pdh

 

4,5

 

kW

Tj = bivalent

COPd

 

2,1

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

 

 

kW

Tj = operating limit

COPd

 

2,1

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

-

 

heating/Warmer

Tol

 

-

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

287

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

1658

 

kWh/a

thermostat-off mode

PTO

 

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

60,0/65,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

750/2040

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents According to Commission Regulation EU No 206/2012 ErP InformationAC Product
Related manuals
Manual 29 pages 34.03 Kb Manual 12 pages 13.9 Kb Manual 29 pages 8.16 Kb Manual 31 pages 24.14 Kb Manual 29 pages 42.57 Kb Manual 29 pages 59.06 Kb Manual 29 pages 43.99 Kb Manual 29 pages 17.07 Kb Manual 1 pages 26.59 Kb

AR18FSSKABEXEU specifications

The Samsung AR18FSSKABEXEU is a standout model in the realm of air conditioning systems, designed to provide optimal comfort with cutting-edge technology. This wall-mounted air conditioner is particularly renowned for its impressive energy efficiency and user-friendly features, making it an ideal choice for residential and commercial spaces.

One of the main features of the AR18FSSKABEXEU is its remarkable energy efficiency ratings. Leveraging Samsung's advanced Digital Inverter technology, this air conditioning unit is capable of maintaining the desired temperature with minimal energy consumption. Unlike traditional air conditioners that frequently turn on and off, the digital inverter system adjusts the compressor speed based on the cooling requirements, leading to significant savings on energy bills.

Equipped with a powerful cooling capacity of 18,000 BTU, the AR18FSSKABEXEU can effectively cool medium to large-sized rooms. Its Turbo Cooling feature allows for rapid cooling, ensuring that the space reaches comfortable temperatures in no time. This is particularly beneficial during hot summer months when quick respite from the heat is essential.

In terms of air quality, the AR18FSSKABEXEU integrated a comprehensive filtration system. The washable and reusable filters capture dust and allergens, promoting cleaner and healthier indoor air. Additionally, the unit operates quietly, with sound levels as low as 19 dB, ensuring a peaceful environment, whether you are sleeping, working, or relaxing.

The design of the AR18FSSKABEXEU is both sleek and modern, allowing it to seamlessly blend into various interior décors. Its easy-to-use remote control and intuitive interface make operation straightforward. Moreover, Samsung's Smart Wi-Fi feature allows users to control the air conditioner remotely via their smartphones, providing added convenience and flexibility.

The durability of the AR18FSSKABEXEU is another notable characteristic. Constructed with high-quality materials, this air conditioning unit is designed to withstand the test of time. Its advanced compressor technology also contributes to reduced wear and tear, ensuring long-lasting performance.

In summary, the Samsung AR18FSSKABEXEU is an exemplary air conditioning solution that combines efficiency, performance, and ease of use. With its state-of-the-art features, it not only provides comfort but also enhances the overall quality of air within your space, making it a wise investment for any property.