OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATIONAL TEMPERATURE

INDOOR HUMIDITY

IF OUT OF CONDITIONS

INDOOR

OUTDOOR

 

 

 

 

 

 

 

Condensation may occur on

COOLING

16˚C to 32˚C

-10˚C to 43˚C

80% or less

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

HEATING

27˚C or less

-15˚C to 24˚C

-

Internal protection triggers and

the air conditioner will stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensation may occur on

DRYING

18˚C to 32˚C

-10˚C to 43˚C

-

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.

36_ appendix

Image 35
Contents Function Cool Summer OfferCost Efficient System Look for EverywhereDeath Safety informationSafety Information Important safety symbols and precautionsEnsure no water gets into the air conditioner Potential risk of injury or electric shock Do not open the front grille during operation Insufficient ventilation may result in poor performance Potential risk of fire or loss of property Contents Main parts Power buttonViewing your air conditioner Checking the Indoor Unit and DisplayChecking the Outdoor Unit Power button, Room temperature sensor and Humidity sensorOpening the Front Panel Checking the Remote Control Inserting the batteries Remote control displayUsing the remote control Auto Selecting Operation ModeOperating basic function Turning the AIR Conditioner on and OFFCool Set the temperatureDry Fan Heat Horizontal air flow Adjusting the AIR Flow DirectionVertical air flow To deactivate Turbo function Using advanced functionsUsing the Turbo Function To deactivate the On Timer Setting TimerOn Timer To deactivate the Off Timer Off TimerPreset time of On Timer is longer than Off Timer Combining On Timer and Off TimerTo deactivate the timer combination Preset time of On Timer is shorter than Off TimerMode Wake up from mode Temperature changes in modeTo deactivate mode To deactivate function Using the Smart Saver FunctionUsing the Function To deactivate the Smart Saver functionAutoheat, Heat, Fan mode approximately 15 minutes Using the Evaporator Clean FunctionTo deactivate the Comfort Care function Using the Comfort Care FunctionUsing the Filter Reset Cleaning and maintaining the air conditionerCleaning the Exterior Air filter Cleaning the FilterBio filter Deodorizing filter Replacing the FilterMonths Year Maintaining Your AIR ConditionerPeriodical checks Type Description Every Once aType Description Internal protections via the unit control systemAppendix TroubleshootingCooling Operation RangesMemo Questions or COMMENTS? Air Conditioner
Related manuals
Manual 36 pages 34.2 Kb Manual 27 pages 5.64 Kb Manual 29 pages 50.65 Kb Manual 27 pages 58.82 Kb Manual 36 pages 30.63 Kb Manual 27 pages 59.41 Kb Manual 28 pages 47.65 Kb Manual 1 pages 27.39 Kb Manual 30 pages 48.15 Kb Manual 28 pages 17.87 Kb Manual 28 pages 33.44 Kb Manual 28 pages 15.91 Kb Manual 1 pages 26.59 Kb