Lytespan® Track Lighting System 7531
Page 1 of 2
Lighting Data
40" | 38" | |
60º |
| |
|
| |
| 10' | |
| 47 fc | 5' - 6" |
| 48 fc |
|
Dramalux® Wall Washer
EXAMPLE: With track located 40” from wall, on 10’ ceiling and multiple units spaced 38” on center and aimed 60° from horizontal, the illumination on wall 5’6” from floor will be 48 f.c. beneath units and 47 f.c. between units.
8’ - 0” Ceiling Height - Track 22” from Wall*
Distance From Ceiling
Track Dist. From Wall |
| Footcandles on Wall From Single Unit |
| Footcandles on Wall from Multiple Units† | ||||||
22” | 6” | 12” | 18” | 24” | 30” | 36” | 42” | 48” | 18” | 27” |
60º |
|
| Distance to Side of Unit |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
0’ | 11.0 | 6.5 | 5.5 | 3.0 | 2.0 | 1.5 | 1.0 | 0.5 | 0.5 | 19.5 | 16.5 | 19.5 | 15.0 | 10.5 | 15.0 |
1’ | 70.0 | 65.0 | 34.0 | 12.0 | 5.5 | 3.0 | 1.5 | 1.0 | 1.0 | 97.0 | 109.5 | 97.0 | 80.0 | 48.5 | 80.0 |
2’ | 115.0 110.0 | 66.0 | 26.0 | 9.0 | 3.5 | 2.0 | 1.0 | 1.0 | 171.0 190.5 | 171.0 | 129.0 | 95.0 | 129.0 | ||
2.5’ | 140.0 130.0 | 80.0 | 36.0 | 14.0 | 4.5 | 2.5 | 1.5 | 1.0 | 217.0 231.0 | 217.0 | 160.0 120.0 160.0 | ||||
3’ | 120.0 115.0 | 77.0 | 39.0 | 16.5 | 6.0 | 2.5 | 1.5 | 1.5 | 203.0 217.0 | 203.0 | 144.0 120.0 144.0 | ||||
4’ | 48.0 | 48.0 | 40.0 | 24.0 | 14.0 | 7.5 | 3.0 | 2.0 | 1.5 | 102.0 113.0 | 102.5 | 71.0 | 69.0 | 71.0 | |
5’ | 17.0 | 17.0 | 16.0 | 11.5 | 8.5 | 5.5 | 3.0 | 2.0 | 1.5 | 46.5 | 51.0 | 46.5 | 33.0 | 32.5 | 33.0 |
6’ | 8.0 | 7.0 | 8.0 | 6.0 | 5.0 | 3.5 | 2.8 | 2.0 | 1.5 | 25.5 | 27.0 | 25.5 | 18.5 | 18.5 | 18.5 |
7’ | 4.0 | 4.0 | 5.0 | 3.5 | 3.0 | 3.0 | 2.0 | 2.0 | 1.0 | 15.0 | 18.5 | 15.0 | 12.0 | 12.5 | 12.0 |
8’ | 2.5 | 3.0 | 3.0 | 2.5 | 2.5 | 2.5 | 2.0 | 1.5 | 0.5 | 11.5 | 14.0 | 11.5 | 9.0 | 0.0 | 9.0 |
10’ - 0” Ceiling Height - Track 40” from Wall*
Distance From Ceiling
Track Dist. From Wall | Footcandles on Wall From Single Unit | Footcandles on Wall from Multiple Units† |
40” | 12” | 24” | 36” | 48” | 60” | 72” | 84” | 38” | 57” |
60º |
|
| Distance to Side of Unit |
|
|
| |||
|
|
|
|
|
|
|
|
|
0’ | 6.0 | 5.0 | 2.5 | 2.5 | 2.0 | 1.0 | 0.5 | 0.0 | 12.0 | 9.5 | 12.0 | 7.5 | 6.0 | 7.5 |
1’ | 13.0 | 11.0 | 9.0 | 3.5 | 2.0 | 1.0 | 0.5 | 0.5 | 21.5 | 24.0 | 21.5 | 17.0 | 13.5 | 17.0 |
2’ | 23.0 | 18.0 | 12.0 | 4.5 | 3.0 | 1.0 | 0.5 | 0.5 | 32.5 | 33.0 | 32.5 | 26.0 | 18.0 | 26.0 |
3’ | 25.0 | 23.0 | 14.5 | 5.0 | 3.0 | 1.0 | 0.5 | 0.5 | 36.5 | 40.5 | 36.5 | 28.0 | 21.0 | 28.0 |
4’ | 33.0 | 27.0 | 15.0 | 6.0 | 2.5 | 1.0 | 0.5 | 0.5 | 48.0 | 45.0 | 48.0 | 36.0 | 22.5 | 36.0 |
4.5’ | 34.0 | 28.0 | 16.0 | 6.0 | 2.5 | 1.0 | 1.0 | 0.5 | 48.0 | 47.0 | 48.0 | 37.0 | 23.5 | 37.0 |
5’ | 28.0 | 25.0 | 15.0 | 6.0 | 2.5 | 1.5 | 1.0 | 0.5 | 41.0 | 43.0 | 41.0 | 31.5 | 22.0 | 31.5 |
6’ | 20.0 | 18.0 | 13.0 | 5.5 | 2.0 | 1.5 | 1.0 | 0.5 | 32.0 | 34.0 | 32.0 | 23.5 | 20.0 | 23.5 |
7’ | 15.0 | 13.0 | 9.0 | 4.0 | 1.5 | 1.5 | 1.0 | 1.0 | 25.0 | 25.0 | 25.0 | 18.0 | 14.5 | 18.0 |
8’ | 10.0 | 8.5 | 6.0 | 3.0 | 1.5 | 1.5 | 1.0 | 1.0 | 18.0 | 18.0 | 18.0 | 13.0 | 10.5 | 13.0 |
9’ | 8.0 | 7.0 | 4.5 | 2.0 | 1.5 | 1.5 | 1.0 | 1.0 | 14.0 | 14.0 | 14.0 | 11.0 | 8.5 | 11.0 |
10’ | 5.0 | 4.0 | 3.5 | 1.5 | 1.5 | 1.5 | 1.0 | 1.0 | 9.0 | 10.5 | 9.0 | 7.5 | 6.5 | 7.5 |
12’ - 0” Ceiling Height - Track 66” from Wall*
Distance From Ceiling
Track Dist. From Wall | Footcandles on Wall From Single Unit | Footcandles on Wall from Multiple Units† |
66” | 12” | 24” | 36” | 48” | 60” | 72” | 84” | 96” | 62” | 93” |
| 60º |
| Distance to Side of Unit |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
0’ | 3.5 | 3.0 | 2.5 | 2.0 | 1.0 | 1.0 | 0.5 | 0.5 | 0.5 | 5.0 | 5.0 | 5.0 | 4.0 | 3.0 | 4.2 |
1’ | 5.5 | 5.0 | 4.0 | 3.0 | 1.5 | 1.0 | 0.5 | 0.5 | 0.5 | 7.5 | 7.5 | 7.5 | 6.0 | 3.5 | 6.2 |
2’ | 8.0 | 7.5 | 5.5 | 3.5 | 2.0 | 1.5 | 1.0 | 0.5 | 0.5 | 10.5 | 10.0 | 10.5 | 8.5 | 5.0 | 8.8 |
3’ | 9.0 | 8.5 | 7.0 | 4.5 | 2.5 | 1.5 | 1.0 | 1.0 | 0.5 | 12.0 | 12.0 | 12.0 | 9.5 | 5.5 | 9.5 |
4’ | 10.0 | 10.0 | 8.0 | 5.5 | 3.0 | 2.0 | 1.0 | 1.0 | 0.5 | 13.5 | 14.5 | 13.5 | 10.5 | 6.5 | 10.6 |
5’ | 12.5 | 12.0 | 10.0 | 6.5 | 3.5 | 2.0 | 1.0 | 1.0 | 0.5 | 17.0 | 17.5 | 17.0 | 13.5 | 8.0 | 13.4 |
6’ | 15.0 | 14.0 | 11.0 | 7.5 | 4.5 | 2.5 | 1.5 | 1.0 | 1.0 | 20.0 | 20.0 | 20.0 | 16.5 | 9.5 | 16.4 |
6.5’ | 15.0 | 14.0 | 11.0 | 8.0 | 4.5 | 3.0 | 1.5 | 1.0 | 0.5 | 21.5 | 20.5 | 21.5 | 16.5 | 10.0 | 16.4 |
7’ | 14.0 | 12.5 | 10.5 | 7.5 | 4.5 | 3.0 | 1.5 | 1.0 | 0.5 | 20.0 | 19.5 | 20.0 | 15.0 | 9.5 | 15.6 |
8’ | 12.5 | 11.5 | 10.0 | 7.0 | 4.0 | 3.0 | 1.5 | 1.5 | 0.5 | 18.5 | 18.0 | 18.5 | 13.5 | 9.0 | 13.6 |
9’ | 10.0 | 9.0 | 8.0 | 6.0 | 4.0 | 3.0 | 1.5 | 1.5 | 0.5 | 16.0 | 15.0 | 16.0 | 11.0 | 8.5 | 11.2 |
10’ | 8.5 | 8.0 | 7.0 | 5.0 | 4.0 | 3.0 | 1.5 | 1.5 | 0.5 | 14.0 | 13.5 | 14.0 | 19.5 | 8.5 | 19.6 |
11’ | 7.0 | 6.5 | 6.0 | 4.5 | 3.0 | 3.0 | 1.5 | 1.5 | 0.5 | 12.5 | 11.0 | 12.5 | 7.5 | 7.0 | 7.6 |
12’ | 5.5 | 5.0 | 4.2 | 3.0 | 3.0 | 2.0 | 1.5 | 1.5 | 0.5 | 9.5 | 8.5 | 9.5 | 6.0 | 6.5 | 6.2 |
*At recommended track distance from wall for corresponding ceiling height, wall washer will provide maximum illumination at eye level (5’- 6” above floor) when aimed 60° from horizontal (I.E.S. recommended practice).
† Footcandles shown in table for multiple units are based on a minimum of 5 units when on 18”, 27”, or 38” centers and 3 units when on 57”, 62”, or 93” centers.
Footcandles values are based on average room conditions.
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902