4. Test Information

Test Parameters

 

Parameters

Actual

Parameters

Actual

 

 

 

 

 

 

Ambient temperature

25.8

Test Voltage

230V

 

 

 

 

 

 

Total harmonic distortion

1.2%

Test Frequency

50Hz

 

 

 

 

 

 

Test Instrumentations

 

 

 

 

 

 

 

 

 

Test instrumentation

Model name

Manufacture

Expire date of Calibration

 

 

 

 

 

 

Stopwatch

PC80A

Time Art

15th Sep. 2014

 

Power meter

PPA2530

Newtons4th Ltd

20th Sep. 2014

 

 

 

 

 

 

Power Supply

345AMX

PACIFIC

22th Dec. 2014

 

 

 

 

 

Set-up and circuit for electrical testing

4. Reference for test method

-EN 62301 ed. 2.0; Household electrical appliances – Measurement of standby power

-IEC 62323 ed. 1.0; Desktop and notebook computers – Measurement of energy consumption

-ECMA-383 3rd Edition; Measuring the Energy Consumption of Personal Computing Products

-US EPA "Test Method for calculating the Energy efficiency of single voltage External AC-DC and AC-AC Power Supplies"

-ISO 7779 :2010; Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment

-ISO 9296:1988; Acoustics - Declared noise emission values of computer and business equipment