Lightolier 8038 specifications 42W, 32W Quick Calculator, Spacing Ratio Along = 1.4 Across =

Page 2

Page 2 of 2

32W

Quick Calculator

 

100

 

 

 

 

 

 

ROOM SURFACE REFLECTANCES:

 

90

 

 

 

 

 

 

80% Ceiling; 50% Wall; 20% Floor

 

 

 

 

 

 

 

 

2400 Lumens Per Lamp

 

 

 

80

 

 

 

 

 

 

 

 

FOOTCANDLES

 

 

 

 

 

 

RCR= 1(Rm. Width= 10xMtg. Ht. above work plane)

 

 

 

 

 

 

 

70

 

 

 

 

 

 

RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)

 

60

 

 

 

 

 

 

RCR=10 (Rm. Width= Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

INITIAL

40

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

50

 

75

100

125

150

175

200

225

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

4

5

6

7

8

9

10

11

12

13

14

15

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick calculator chart determines the number and spacing of 2 It. - 32 W PL-T units with clear reflector: for any level of illumination. For 26W lamps, multiply footcandles by 0.8.

Spacing Ratio: Along = 1.4 Across = 1.6

CERTIFIED TEST REPORT N0. ITL44462

INDEPENDENT TESTING LABORATORIES, INC.

RECESSED CALCULITE DOWNLIGHT 8-11/16" APERTURE SPECULAR CLEAR REFLECTOR

TWO PHILIPS 32-WATT 32W/35/4P TRIPLE U-TUBE. COMPACT FLUORESCENTS.

HORIZONTAL POSITION. LUMEN RATING =2400 LMS

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

ANGLE

0.0

45.0

90.0

135.0

180.0

FLUX

 

 

90

0

1499 1499

1499

1499

1499

 

 

 

5

1502 1555

1643

1573

1426

152

 

 

15

1546 1829

2017

1862

1330

505

 

 

25

1628 2073

2090

1747

1440

844

 

 

7535

1312 1820

1842

1573

1242

1007

 

 

45

823

1034

1242

1222

1181

849

700

 

55

31

55

61

58

61

118

 

 

65

2

2

3

2

2

3

 

 

6075

1

1

1

1

1

1

 

 

85

0

0

0

0

0

0

 

 

90

0

0

0

0

0

 

1400

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

45

ZONE

LUMENS

% LAMP

%LUMINAIRE

 

 

 

0-30

 

1500

31.3

 

43.1

 

 

 

0-40

 

2508

52.2

 

72.1

 

 

 

0-60

 

3475

72.4

 

99.9

2100

 

 

0-90

 

3479

72.5

 

100.0

 

 

90-180

 

0

0.0

 

0.0

 

 

 

 

 

0

15

30

0-180

 

3479

72.5

 

100.0

 

** EFFICIENCY = 72.5% **

 

 

0-deg:

 

 

 

 

90-deg:

 

 

 

 

 

 

 

 

 

180-deg:

 

 

 

 

 

 

 

 

DATE: Dec 4, 1995

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE

GREATEST LUMINOUS OPENING OF LUMINAIRE.

Coefficients of Utilization

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

 

50

30

10

 

50

30

10

50

30

10

0

 

 

 

 

 

1

79

.77

.75

.78

.76

.74

 

.75 .73 .72

 

.72

.71

.70

.69 .68 .68

.66

RATIO

2

.72

.69

.66

.71

.68

.65

 

.69

.66

.64

 

.66

.64

.62

.64

.62

.61

.60

3

.66

.62

.58

.65

.61

.58

 

.63

.59

.57

 

.61

.58

.56

.59

.57

.55

.54

 

 

 

CAVITY

4

.60

.55

.52

.59

.55

.51

 

.58

.54

.51

 

.56

.53

.50

.55

.52

.49

.48

6

.50

.45

.41

.50

.45

.41

 

.48

.44

.41

 

.47

.43

.40

.46

.43

.40

.39

 

5

.55

.50

.46

.54

.49

.46

 

.53

.49

.45

 

.51

.48

.45

.50

.47

.44

.43

ROOM

7

.46

41

.37

.46

.41

.37

 

.45

.40

.37

 

.44

.40

.37

.43

.39

.36

.35

8

.42

.37

.34

.42

.37

.34

 

.41

.37

.33

 

.40

.36

.33

.40

.36

.33

.32

 

 

 

 

9

.39

.34

.31

.39

.34

.31

 

.38

.34

.30

 

.37

.33

.30

.37

.33

.30

.29

 

10

.36

.31

.28

.36

.31

.28

 

.35

.31

.28

 

.35

.31

.28

.34

.30

.28

.26

20% FLOOR CAVITY REFLECTANCE For 26W lamps, multiply C.U.'s by 1.1.

Calculite® CFL Open Downlight  8038

8" Aperture (2) Triple Tube Horizontal Lamp

42W

Quick Calculator

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM SURFACE REFLECTANCES:

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

80% Ceiling; 50% Wall; 20% Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3200 Lumens Per Lamp

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOOTCANDLES

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR= 1(Rm. Width= 10xMtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR=10 (Rm. Width= Mtg. Ht. above work plane)

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

50

 

75

100

125

150

175

200

225

 

 

 

 

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

 

 

4

5

 

6

7

 

8

9

10

11

12

 

13

 

14

 

15

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick calculator chart determines the number and spacing of 2 It. - 42 Watt PL-T units with clear reflector: for any level of illumination.

Spacing Ratio: Along = 1.4 Across = 1.7

CERTIFIED TEST REPORT N0. ITL44463

INDEPENDENT TESTING LABORATORIES, INC.

RECESSED CALCULITE DOWNLIGHT 8038CLIF/8242HE120

8 ? " APERTURE SPECULAR CLEAR REFLECTOR

TWO PHILIPS 42-WATT PL-T 42W/4P TRIPLE U-TUBE. COMPACT FLUORESCENTS.

HORIZONTAL POSITION. LUMEN RATING =3200 LMS

 

 

 

 

CANDLE POWER SUMMARY

 

 

 

 

ANGLE

0.0

45.0

90.0

135.0

180.0

FLUX

 

 

90

0

1800

1800

1800

1800

1800

 

 

 

5

1748

1821

1960

1951

1817

184

 

 

 

15

1695

2065

2423

2380

1892

616

 

 

75

25

1828

2305

2516

2461

2082

1048

 

 

35

1505

2016

2330

2138

1821

1264

 

 

 

45

1135

1419

1505

1454

1366

1063

800

 

 

55

49

83

63

53

46

142

 

 

60

65

4

3

3

3

2

3

 

 

75

1

1

1

1

1

1

 

 

 

 

 

 

85

0

0

0

0

0

0

 

 

 

90

0

0

0

0

0

 

1600

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

45

ZONE

LUMENS

% LAMP %LUMINAIRE

 

 

 

0-30

 

1847

 

28.9

 

42.8

 

 

 

0-40

 

3112

 

48.6

 

72.0

 

 

 

0-60

 

4316

 

67.4

 

99.9

2400

 

 

0-90

 

4320

 

67.5

 

100.0

 

15

 

90-180

0

 

0.0

 

0.0

0

30

0-180

 

4320

 

67.5

 

100.0

 

0-deg:

 

 

** EFFICIENCY = 67.5% **

 

 

90-deg:

 

 

 

 

 

 

 

 

 

 

 

 

 

180-deg:

 

 

 

 

 

 

 

 

DATE: Jan 3, 1996

PREPARED FOR:

LIGHTOLIER, Fall River, MA

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE

GREATEST LUMINOUS OPENING OF LUMINAIRE.

Coefficients Of Utilization

 

 

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

 

10

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

 

50

30

10

 

50

30

10

 

50

30

10

0

 

 

 

 

 

 

1

.74

.72

.70

.72

.70

.69

 

.69

.68

.67

 

.67

.66

.65

 

.65

.64

.63

.62

 

RATIO

2

.67

.64

.61

.66

.63

.61

 

.64

.61

.59

 

.62

.60

.58

 

.60

.58

.57

.56

 

3

.61

.57

.54

.60

.57

.54

 

.58

.55

.53

 

.57

.54

.52

 

.55

.53

.51

.50

 

CAVITY

4

.56

.51

.48

.55

.51

.48

 

.54

.50

.47

 

.52

.49

.46

 

.51

.48

.46

.45

 

5

.51

.46

.43

.50

.46

.43

 

.49

.45

.42

 

.48

.44

.42

 

.47

.44

.41

.40

 

 

 

 

 

 

 

6

.47

.42

.38

.46

.42

.38

 

.45

.41

.38

 

.44

.40

.38

 

.43

.40

.37

.36

 

ROOM

7

.43

.41

.37

.46

.41

.37

 

.45

.40

.37

 

.44

.40

.37

 

.43

.39

.36

.35

 

9

.36

.32

.28

.36

.31

.28

 

.35

.31

.28

 

.35

.31

.28

 

.34

.31

.28

.27

 

 

8

.39

.35

.31

.39

.34

.31

 

.38

.34

.31

 

.37

.34

.31

 

.37

.33

.31

.30

 

 

10

.34

.29

.26

.33

.29

.26

 

.33

.29

.26

 

.32 .28 .26

 

.32

.28

.26

.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

 

Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • D0708

Lightolier is a Philips group brand

Image 2
Contents Reflector Trim FeaturesOptions and Accessories Remodeler Frame-In KitsSpacing Ratio Along = 1.4 Across = 42W32W Quick Calculator Coefficients of Utilization