Page 2 of 2
32W
Quick Calculator
| 100 |
|
|
|
|
|
| ROOM SURFACE REFLECTANCES: | ||||
| 90 |
|
|
|
|
|
| 80% Ceiling; 50% Wall; 20% Floor |
| |||
|
|
|
|
|
|
| 2400 Lumens Per Lamp |
|
| |||
| 80 |
|
|
|
|
|
|
|
| |||
FOOTCANDLES |
|
|
|
|
|
| RCR= 1(Rm. Width= 10xMtg. Ht. above work plane) | |||||
|
|
|
|
|
|
| ||||||
70 |
|
|
|
|
|
| RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane) | |||||
| 60 |
|
|
|
|
|
| RCR=10 (Rm. Width= Mtg. Ht. above work plane) | ||||
|
|
|
|
|
|
|
|
|
|
|
| |
| 50 |
|
|
|
|
|
|
|
|
|
|
|
INITIAL | 40 |
|
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 20 |
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
| 25 |
| 50 |
| 75 | 100 | 125 | 150 | 175 | 200 | 225 |
|
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
| |||||
| 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 2 It. - 32 W
Spacing Ratio: Along = 1.4 Across = 1.6
CERTIFIED TEST REPORT N0. ITL44462
INDEPENDENT TESTING LABORATORIES, INC.
RECESSED CALCULITE DOWNLIGHT
TWO PHILIPS
HORIZONTAL POSITION. LUMEN RATING =2400 LMS
|
|
|
| CANDLEPOWER SUMMARY |
| ||||
|
| ANGLE | 0.0 | 45.0 | 90.0 | 135.0 | 180.0 | FLUX | |
|
| 90 | 0 | 1499 1499 | 1499 | 1499 | 1499 |
| |
|
| 5 | 1502 1555 | 1643 | 1573 | 1426 | 152 | ||
|
| 15 | 1546 1829 | 2017 | 1862 | 1330 | 505 | ||
|
| 25 | 1628 2073 | 2090 | 1747 | 1440 | 844 | ||
|
| 7535 | 1312 1820 | 1842 | 1573 | 1242 | 1007 | ||
|
| 45 | 823 | 1034 | 1242 | 1222 | 1181 | 849 | |
700 |
| 55 | 31 | 55 | 61 | 58 | 61 | 118 | |
|
| 65 | 2 | 2 | 3 | 2 | 2 | 3 | |
|
| 6075 | 1 | 1 | 1 | 1 | 1 | 1 | |
|
| 85 | 0 | 0 | 0 | 0 | 0 | 0 | |
|
| 90 | 0 | 0 | 0 | 0 | 0 |
| |
1400 |
|
| ZONAL LUMENS AND PERCENTAGES | ||||||
|
| 45 | ZONE | LUMENS | % LAMP | %LUMINAIRE | |||
|
|
|
| 1500 | 31.3 |
| 43.1 | ||
|
|
|
| 2508 | 52.2 |
| 72.1 | ||
|
|
|
| 3475 | 72.4 |
| 99.9 | ||
2100 |
|
|
| 3479 | 72.5 |
| 100.0 | ||
|
|
| 0 | 0.0 |
| 0.0 | |||
|
|
|
|
| |||||
0 | 15 | 30 |
| 3479 | 72.5 |
| 100.0 | ||
| ** EFFICIENCY = 72.5% ** |
| |||||||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
DATE: Dec 4, 1995
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
Coefficients of Utilization
|
|
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|
|
| |||||||||||
|
|
| 80 |
|
| 70 |
|
|
| 50 |
|
|
| 30 |
|
| 10 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| % WALL REFLECTANCE |
|
|
|
|
|
|
| ||||||
|
| 50 | 30 | 10 | 50 | 30 | 10 |
| 50 | 30 | 10 |
| 50 | 30 | 10 | 50 | 30 | 10 | 0 |
|
|
|
| ||||||||||||||||
| 1 | 79 | .77 | .75 | .78 | .76 | .74 |
| .75 .73 .72 |
| .72 | .71 | .70 | .69 .68 .68 | .66 | ||||
RATIO | 2 | .72 | .69 | .66 | .71 | .68 | .65 |
| .69 | .66 | .64 |
| .66 | .64 | .62 | .64 | .62 | .61 | .60 |
3 | .66 | .62 | .58 | .65 | .61 | .58 |
| .63 | .59 | .57 |
| .61 | .58 | .56 | .59 | .57 | .55 | .54 | |
|
|
| |||||||||||||||||
CAVITY | 4 | .60 | .55 | .52 | .59 | .55 | .51 |
| .58 | .54 | .51 |
| .56 | .53 | .50 | .55 | .52 | .49 | .48 |
6 | .50 | .45 | .41 | .50 | .45 | .41 |
| .48 | .44 | .41 |
| .47 | .43 | .40 | .46 | .43 | .40 | .39 | |
| 5 | .55 | .50 | .46 | .54 | .49 | .46 |
| .53 | .49 | .45 |
| .51 | .48 | .45 | .50 | .47 | .44 | .43 |
ROOM | 7 | .46 | 41 | .37 | .46 | .41 | .37 |
| .45 | .40 | .37 |
| .44 | .40 | .37 | .43 | .39 | .36 | .35 |
8 | .42 | .37 | .34 | .42 | .37 | .34 |
| .41 | .37 | .33 |
| .40 | .36 | .33 | .40 | .36 | .33 | .32 | |
|
|
| |||||||||||||||||
| 9 | .39 | .34 | .31 | .39 | .34 | .31 |
| .38 | .34 | .30 |
| .37 | .33 | .30 | .37 | .33 | .30 | .29 |
| 10 | .36 | .31 | .28 | .36 | .31 | .28 |
| .35 | .31 | .28 |
| .35 | .31 | .28 | .34 | .30 | .28 | .26 |
20% FLOOR CAVITY REFLECTANCE For 26W lamps, multiply C.U.'s by 1.1.
Calculite® CFL Open Downlight 8038
8" Aperture (2) Triple Tube Horizontal Lamp
42W
Quick Calculator
| 100 |
|
|
|
|
|
|
|
|
|
|
|
|
| ROOM SURFACE REFLECTANCES: | |||||||||
| 90 |
|
|
|
|
|
|
|
|
|
|
|
|
| 80% Ceiling; 50% Wall; 20% Floor |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3200 Lumens Per Lamp |
|
|
|
| ||||||
| 80 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
FOOTCANDLES |
|
|
|
|
|
|
|
|
|
|
|
|
| RCR= 1(Rm. Width= 10xMtg. Ht. above work plane) | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
70 |
|
|
|
|
|
|
|
|
|
|
|
|
| RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane) | ||||||||||
| 60 |
|
|
|
|
|
|
|
|
|
|
|
|
| RCR=10 (Rm. Width= Mtg. Ht. above work plane) | |||||||||
| 50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
INITIAL | 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 25 |
| 50 |
| 75 | 100 | 125 | 150 | 175 | 200 | 225 | ||||||||||
|
|
|
|
|
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
|
|
| |||||||||||
| 4 | 5 |
| 6 | 7 |
| 8 | 9 | 10 | 11 | 12 |
| 13 |
| 14 |
| 15 |
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 2 It. - 42 Watt
Spacing Ratio: Along = 1.4 Across = 1.7
CERTIFIED TEST REPORT N0. ITL44463
INDEPENDENT TESTING LABORATORIES, INC.
RECESSED CALCULITE DOWNLIGHT 8038CLIF/8242HE120
8 ? " APERTURE SPECULAR CLEAR REFLECTOR
TWO PHILIPS
HORIZONTAL POSITION. LUMEN RATING =3200 LMS
|
|
|
| CANDLE POWER SUMMARY |
| ||||
|
|
| ANGLE | 0.0 | 45.0 | 90.0 | 135.0 | 180.0 | FLUX |
|
| 90 | 0 | 1800 | 1800 | 1800 | 1800 | 1800 |
|
|
| 5 | 1748 | 1821 | 1960 | 1951 | 1817 | 184 | |
|
|
| 15 | 1695 | 2065 | 2423 | 2380 | 1892 | 616 |
|
| 75 | 25 | 1828 | 2305 | 2516 | 2461 | 2082 | 1048 |
|
| 35 | 1505 | 2016 | 2330 | 2138 | 1821 | 1264 | |
|
|
| 45 | 1135 | 1419 | 1505 | 1454 | 1366 | 1063 |
800 |
|
| 55 | 49 | 83 | 63 | 53 | 46 | 142 |
|
| 60 | 65 | 4 | 3 | 3 | 3 | 2 | 3 |
|
| 75 | 1 | 1 | 1 | 1 | 1 | 1 | |
|
|
| |||||||
|
|
| 85 | 0 | 0 | 0 | 0 | 0 | 0 |
|
|
| 90 | 0 | 0 | 0 | 0 | 0 |
|
1600 |
|
| ZONAL LUMENS AND PERCENTAGES | ||||||
|
| 45 | ZONE | LUMENS | % LAMP %LUMINAIRE | ||||
|
|
|
| 1847 |
| 28.9 |
| 42.8 | |
|
|
|
| 3112 |
| 48.6 |
| 72.0 | |
|
|
|
| 4316 |
| 67.4 |
| 99.9 | |
2400 |
|
|
| 4320 |
| 67.5 |
| 100.0 | |
| 15 |
| 0 |
| 0.0 |
| 0.0 | ||
0 | 30 |
| 4320 |
| 67.5 |
| 100.0 | ||
|
|
| ** EFFICIENCY = 67.5% ** |
| |||||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
DATE: Jan 3, 1996
PREPARED FOR:
LIGHTOLIER, Fall River, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
Coefficients Of Utilization
|
|
|
|
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|
|
|
| |||||||||||
|
|
|
| 80 |
|
| 70 |
|
|
| 50 |
|
|
| 30 |
|
|
| 10 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| % WALL REFLECTANCE |
|
|
|
|
|
|
|
|
|
| ||||
|
| 50 | 30 | 10 | 50 | 30 | 10 |
| 50 | 30 | 10 |
| 50 | 30 | 10 |
| 50 | 30 | 10 | 0 |
| |
|
|
|
| |||||||||||||||||||
| 1 | .74 | .72 | .70 | .72 | .70 | .69 |
| .69 | .68 | .67 |
| .67 | .66 | .65 |
| .65 | .64 | .63 | .62 |
| |
RATIO | 2 | .67 | .64 | .61 | .66 | .63 | .61 |
| .64 | .61 | .59 |
| .62 | .60 | .58 |
| .60 | .58 | .57 | .56 |
| |
3 | .61 | .57 | .54 | .60 | .57 | .54 |
| .58 | .55 | .53 |
| .57 | .54 | .52 |
| .55 | .53 | .51 | .50 |
| ||
CAVITY | 4 | .56 | .51 | .48 | .55 | .51 | .48 |
| .54 | .50 | .47 |
| .52 | .49 | .46 |
| .51 | .48 | .46 | .45 |
| |
5 | .51 | .46 | .43 | .50 | .46 | .43 |
| .49 | .45 | .42 |
| .48 | .44 | .42 |
| .47 | .44 | .41 | .40 |
| ||
|
|
|
|
| ||||||||||||||||||
| 6 | .47 | .42 | .38 | .46 | .42 | .38 |
| .45 | .41 | .38 |
| .44 | .40 | .38 |
| .43 | .40 | .37 | .36 |
| |
ROOM | 7 | .43 | .41 | .37 | .46 | .41 | .37 |
| .45 | .40 | .37 |
| .44 | .40 | .37 |
| .43 | .39 | .36 | .35 |
| |
9 | .36 | .32 | .28 | .36 | .31 | .28 |
| .35 | .31 | .28 |
| .35 | .31 | .28 |
| .34 | .31 | .28 | .27 |
| ||
| 8 | .39 | .35 | .31 | .39 | .34 | .31 |
| .38 | .34 | .31 |
| .37 | .34 | .31 |
| .37 | .33 | .31 | .30 |
| |
| 10 | .34 | .29 | .26 | .33 | .29 | .26 |
| .33 | .29 | .26 |
| .32 .28 .26 |
| .32 | .28 | .26 | .25 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| 20% FLOOR CAVITY REFLECTANCE |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| Job Information |
|
| Type: |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|