Lightolier ADS8G16MS140 Job Information, Consult factory for availability of louver finishes

Page 2
Section 2/Folio G09-10

 

VP PARABOLIC ADS8G16MS140

Page 2 of 2

8”x48” RECESSED FLUORESCENT16 CELL PARABOLIC LOUVER

 

STATIC IES RP24 PREFERRED

AD

S

8

G

16

1

40

 

 

 

 

 

 

 

 

 

 

 

 

Advance

 

 

 

 

Fixture Width

 

 

 

Technology

 

 

 

 

8 = 8

 

 

 

 

 

 

 

 

 

 

Full Width

 

Body Style

 

 

Ceiling Type

Refector Louver

 

S=Static

 

 

 

G = Grid

48” in length

 

 

 

 

 

 

(Lay in T-Bar)

 

 

 

 

 

 

 

 

 

 

 

 

Number of

 

 

Lamp Quantity

 

 

 

Cells

 

 

 

Louver finish

 

MS-Low

Iridescence

Reflector Matte

PS-Low Iridescence

CFI Anodized

Specular

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

Options

 

 

120

 

 

 

 

 

 

Add appropriate

Lamp

 

Ballast Type

 

277

 

 

suffix to calalog

Length

 

 

OC = T8

 

347

 

 

 

no., ie HRD)

40 = 48”

 

SO = Electric

 

 

 

 

 

 

 

 

 

 

 

 

T8

 

 

 

 

 

 

 

DI = dimming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Consult factory for availability of louver finishes.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1 reflectance 80% ceiling, 50% post-wall, 20% floor the CU. shall no be less than 0.69. To prevent glare the VCP shall not be less than 88 either length- wise or crosswise (at 100 fc level) and that the average luminance will conform with the IES RP-24 preferred standard, and have a fixture efficiency of not less than 60%.

MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel.

LOUVER:Post-anodized aluminum.

FINISH: Louver - Low iridescense specular post-wall, anodized vertical grain sheet or Low iridescence reflector matte post-anodized vertical grain sheet. Chassis exterior white baked polyester powder coat.

ELECTRICAL: Rapid start HPF thermally protected class “P” ballast CBM certi- fied by ETL if K.O. is within 3” of ballast use wire suitable for at least 90”. LABELS:Listed by CSA/UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 2
Contents Louver PerformanceMaterials FinishLOUVERPost-anodized aluminum Job InformationConsult factory for availability of louver finishes Technical Information 978 657-7600 Fax 978