Lightolier AGM Performance Upper Compartment, Performance Lower Compartment, Candlepower Curve

Page 3

Lighting Systems Agili-T Pendant Direct/Indirect AGM

Page 3 of 4

Performance Upper Compartment

CANDLEPOWER CURVE

 

 

CANDLEPOWER

 

 

ZONE

 

 

 

 

 

 

DEG

 

0

22,5

45

67,5

90

 

180

322

322

322

322

322

175

317

315

314

322

315

170

317

315

315

324

308

165

312

297

310

316

321

160

295

302

307

317

311

155

289

279

298

323

316

150

265

269

305

314

324

145

251

260

293

331

352

140

229

241

291

370

395

135

207

230

304

452

515

130

176

214

345

621

708

125

156

196

464

777

881

120

133

199

585

943

1067

115

101

222

709

958

962

110

71

272

699

731

754

105

48

319

530

640

664

100

30

264

387

403

418

95

8

138

179

197

195

90

0

0

0

0

0

REPORT NO: LSC8531 1 X 28W T5

UPPER OPTIC

Efficiency: 90.8%. Indirect Maximum candela: 1067 cd

Indirect Peak at: 120°.

1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

80

 

 

 

70

 

 

 

 

50

 

 

 

 

 

 

 

Wall reflectance

 

 

 

 

 

 

70

50

30

70

70

50

30

10

50

30

10

 

 

0

.86

.86

.86

.86

.74

.74

.74

.74

.50

.50

.50

RATIO

1

.79

.75

.72

.69

.67

.64

.62

.58

.44

.42

.41

2

.71

.65

.60

.56

.61

.56

.52

.48

.38

.36

.34

 

 

CAVITY

3

.65

.57

.51

.47

.55

.49

.44

.40

.34

.31

.28

4

.59

.50

.44

.39

.50

.43

.38

.34

.30

.26

.24

 

 

ROOM

5

.54

.44

.38

.33

.46

.38

.33

.29

.26

.23

.20

6

.50

.40

.33

.28

.42

.34

.29

.25

.24

.20

.17

 

 

7

.46

.36

.29

.24

.39

.31

.25

.21

.21

.18

.15

 

 

8

.42

.32

.25

.21

.36

.27

.22

.18

.19

.16

.13

 

 

9

.39

.29

.23

.18

.33

.25

.20

.16

.17

.14

.11

 

 

10

.36

.26

.20

.16

.31

.23

.18

.14

.16

.12

.10

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 31.8

DISTRIBUTION

ZONE

LUMENS

%LAMP

% LUMINAIRE

180-150

258

9.90

10.91

180-140

445

17.07

18.79

180-120

1154

44.22

48.69

180-90

2370

90.82

100.00

140-90

1925

73.76

81.21

120-90

1216

46.60

51.31

0-90

0

.00

.00

0-180

2370

90.82

100.00

Performance Lower Compartment

CANDLEPOWER CURVE

ZONE

DEG

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

REPORT NO: LSC8447 2 X 28W T5 LOWER OPTIC

Efficiency: 54%. Candela at Nadir: 1685 cd

CANDLEPOWER

0

22,5

45

67,5

90

1685

1685

1685

1685

1685

1677

1675

1682

1688

1686

1635

1628

1663

1679

1682

1570

1580

1611

1628

1617

1495

1494

1519

1503

1490

1399

1407

1377

1367

1355

1286

1285

1237

1200

1184

1155

1145

1072

1022

970

1011

976

887

811

777

858

806

689

624

594

664

634

506

464

446

421

421

346

312

275

145

158

186

150

104

5

18

60

46

11

0

0

10

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

80

 

 

 

70

 

 

 

 

50

 

 

 

 

 

 

 

Wall reflectance

 

 

 

 

 

 

70

50

30

10

70

50

30

10

50

30

10

 

 

0

.64

.64

.64

.64

.63

.63

.63

.63

.60

.60

.60

RATIO

1

.61

.59

.58

.56

.60

.58

.57

.55

.56

.55

.54

2

.57

.54

.52

.50

.56

.53

.51

.49

.51

.50

.48

 

 

CAVITY

3

.54

.50

.46

.44

.52

.49

.46

.44

.47

.45

.43

4

.50

.45

.42

.39

.49

.45

.42

.39

.43

.41

.38

 

 

ROOM

5

.47

.41

.38

.35

.46

.41

.37

.35

.40

.37

.34

6

.44

.38

.34

.31

.43

.37

.34

.31

.36

.33

.31

 

 

7

.41

.35

.31

.28

.40

.34

.30

.28

.33

.30

.28

 

 

8

.38

.31

.27

.25

.37

.31

.27

.25

.30

.27

.25

 

 

9

.35

.29

.25

.22

.34

.28

.24

.22

.28

.24

.22

 

 

10

.32

.26

.22

.20

.32

.26

.22

.20

.25

.22

.19

DETERMINED IN ACCORDANCE WITH CURRENTIES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 62.9

DISTRIBUTION

ZONE

LUMENS

%LAMP

% LUMINAIRE

0-30

1243

23.82

44.08

0-40

1910

36.59

67.71

0-60

2770

53.09

98.24

0-90

2821

54.04

100.00

40-90

911

17.45

32.29

60-90

50

.95

1.76

90-180

0

.00

.00

0-180

2821

54.04

100.00

Image 3
Contents Electrical FeaturesOptions and accessories Ordering informationIndividual Control Agili-T AccessoriesSeparate Optics Ordering instructionsCandlepower Curve Performance Upper CompartmentPerformance Lower Compartment Room Cavity Ratio Performance

AGM specifications

Lightolier AGM stands as a leading innovator in the lighting industry, known for its exceptional commitment to quality and advanced technology. With a range of products that cater to both residential and commercial applications, Lightolier AGM emphasizes sustainability without compromising on aesthetic design and functionality.

One of the standout features of Lightolier AGM is its focus on energy efficiency. Utilizing LED technology, their lighting solutions provide substantial energy savings compared to traditional lighting options. This not only reduces electricity bills for consumers but also contributes to a lower carbon footprint, aligning with the global push for sustainable practices. The longevity of LED technology means that consumers benefit from lower maintenance costs, as these fixtures often last up to 25,000 hours or more.

Lightolier AGM is also recognized for its innovative designs. Their extensive product line includes recessed lighting, wall sconces, and track lighting, all of which can enhance the ambiance of any space. The minimalist aesthetic and modern finishes of Lightolier AGM fixtures allow for seamless integration into various design styles, from contemporary to traditional.

Another key characteristic of Lightolier AGM is its commitment to advanced lighting controls. Many of their products are compatible with smart home technology, enabling users to control lighting remotely via smartphone applications or smart assistants. Features such as dimming capabilities and scene settings provide customizable lighting experiences tailored to individual preferences.

Lightolier AGM's products prioritize adaptability and versatility. Their fixtures can be used in a variety of settings, including homes, offices, retail establishments, and hospitality spaces. With adjustable color temperatures and light outputs available in many of their products, users can create the perfect atmosphere for different occasions and tasks.

In addition to its technical attributes, Lightolier AGM places a strong emphasis on safety and compliance. Their products meet stringent quality standards and regulations, ensuring that consumers can trust their lighting solutions to be safe, durable, and reliable.

In summary, Lightolier AGM represents a blend of energy efficiency, cutting-edge design, and smart technology. Their innovative lighting solutions cater to a diverse range of needs while promoting sustainability, making them a preferred choice for both residential and commercial consumers. As they continue to evolve and adapt to changing market demands, Lightolier AGM remains at the forefront of the lighting industry, providing high-quality products that enhance the spaces we inhabit.