Lightolier Baselyte-BSL17 specifications Wiring Options 2 Circuit Center/Outer Switching

Page 7

 

Lighting SystemsBaselyte-BSL17

Page of 8

4 Light T5 HO Semi-Indirect

Wiring Options: 2 Circuit Center/Outer Switching

2 Circuit Center/Outer Switching

Type 2: 2cct.

Type 9: 2cct. w/1cct. thru wire

Type I: 2cct. w/2cct. thru wire

























Fixture wired for two circuit. Lamps wired for center/outer switching.

2 Circuit Center/Outer Switching with Emergency Circuit/Night Light (EC/NL)

Type 4: 2cct. w/EC/NL





%#.,





%#.,





%#.,





%#.,

One 4’ section in two circuit fixture (center/outer switching) to be wired on a separate thru circuit. Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.

2 Circuit Center/Outer Switching with Emergency Battery Pack (EM)

Type 6: Chloride standard CTP700

Type N: Bodine standard LP550

Type F: Chloride high performance CTP1300

Type Q: Bodine high performance LP600

















 %-







Fixture wired for two circuits (center/outer switching), plus a battery pack is wired to one lamp. A hot lead is connected to the battery pack and would act as a ‘trigger’ wire when connected to a constant hot by installer. Leads for both normal circuit and battery pack are wired to fixture ends.

*Note: Multi-lamp battery packs are also available.

2 Circuit Center/Outer with Emergency Circuit/Night Light and Emergency Battery Pack

Type K: Chloride standard CTP700





%#.,





%#.,





%#., %-





%#.,

One 4’ section in a two circuit fixture (center/outer switching) to be wired on a separate thru circuit, in addition, a battery pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together or wired separately if controlled independently. Leads for normal circuit, EC/NL circuit and battery pack are wired to fixture ends. All lamps in EC/NL section to be wired together.

*Note: Multi-lamp battery packs are also available.

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Image 7
Contents Ordering Information SpecificationsOrdering Instructions System Components & Accessories Run ConfigurationModule Lengths & Mounting Distances Mount Type T-Bar 9/16 On-Grid Mounting OptionsMount Type T-Bar 15/16 On-Grid Supension LengthMount Type T-Bar Variable Position Mount Type T-Bar Fixed Position 1/4-20 Threaded RodMount Type Support or Open-Joist Ceiling Cord Types Mount Type Non-Accessible Ceilings concrete, gypsum etcConductor Circuit with Emergency Battery Pack EM Wiring Options 1 CircuitCircuit Type 1 1cct Circuit Center/Outer Switching Type 2 2cct Wiring Options 2 Circuit Center/Outer SwitchingType K Chloride standard CTP700 Type L Chloride standard CTP700 Circuit A/B Switching alternate 4’ sections Type B 2cctType D Chloride standard CTP700 Type O Bodine standard LP550