| Vetro Architectural Decorative FP03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Page 2 of 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Pendant |
Catalog No. FPO3/FP01, 32W Triple Tube, 2400 Lumens.
0 |
|
67 |
|
134 | 60° |
| |
200 |
|
267 | 30° |
Report No. 3095FR
SC = 2.0
CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | ZONAL LUMENS AND PERCENTAGES |
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| |||||||||||||
Angle Mean CP | Angle Mean CP |
| Zone | Lumens |
| Zone | Lumens | %Lamp | %Fixt |
| Ceiling |
| 80% |
| 70% | 50% | 30% |
| |||||||
0 | 140 | 95 | 123 | 16.16 |
| 204.54 | 8.5 | 11.9 |
|
|
|
| |||||||||||||
|
| Wall |
| 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | |||||||||||
5 | 157 | 100 | 122 | 65.89 |
| 362.64 | 15.1 | 21.1 |
|
| |||||||||||||||
|
| RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||||||||||||
10 | 194 | 105 | 119 | 122.49 |
| 683.78 | 28.5 | 39.8 |
|
| |||||||||||||||
|
|
| 0 | 79 | 79 | 79 | 79 | 75 | 75 | 66 | 66 | 58 | 58 | 47 | |||||||||||
15 | 232 | 110 | 116 | 158.1 |
| 1121.98 | 46.7 | 65.3 |
|
| |||||||||||||||
|
|
| 1 | 70 | 66 | 62 | 58 | 61 | 55 | 54 | 49 | 47 | 43 | 43 | |||||||||||
20 | 256 | 115 | 112 | 163.81 |
| 370.57 | 15.4 | 21.6 |
|
| |||||||||||||||
|
|
| 2 | 63 | 56 | 50 | 46 | 52 | 43 | 46 | 38 | 40 | 34 | 27 | |||||||||||
25 | 267 | 120 | 106 | 157.34 |
| 459.74 | 19.2 | 26.7 |
| Ratio | |||||||||||||||
|
| 3 | 57 | 48 | 42 | 37 | 45 | 35 | 40 | 31 | 34 | 28 | 22 | ||||||||||||
30 | 265 | 125 | 99 | 152.38 |
| 566.71 | 23.6 | 26.7 |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
35 | 254 | 130 | 92 | 147.13 |
| 597.18 | 54.9 | 34.7 |
| Cavity | 4 | 52 | 42 | 36 | 31 | 40 | 29 | 35 | 26 | 30 | 23 | 18 | |||
|
| 5 | 47 | 38 | 31 | 26 | 35 | 25 | 31 | 22 | 27 | 20 | 18 | ||||||||||||
40 | 235 | 135 | 84 | 138.68 |
| 1719.16 | 71.6 | 100 |
|
| |||||||||||||||
|
| Room | 6 | 43 | 34 | 27 | 22 | 32 | 21 | 28 | 19 | 24 | 17 | 13 | |||||||||||
45 | 212 | 140 | 75 | 133.65 |
| ** Efficiency = 71.6% ** |
|
| |||||||||||||||||
|
|
| 7 | 40 | 30 | 24 | 19 | 28 | 18 | 25 | 17 | 22 | 15 | 11 | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
50 | 190 | 145 | 66 | 126.18 |
|
|
|
|
|
|
| 8 | 37 | 27 | 21 | 17 | 26 | 16 | 23 | 15 | 20 | 13 | 10 | ||
55 | 175 | 150 | 57 | 110.74 |
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
| 9 | 34 | 25 | 19 | 15 | 23 | 14 | 21 | 13 | 18 | 12 | 9 | |||||||
60 | 163 | 155 | 47 | 89.16 |
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
| 10 | 32 | 23 | 17 | 13 | 22 | 13 | 19 | 12 | 17 | 10 | 8 | |||||||||
65 | 153 | 160 | 37 | 65.13 |
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
| Determined In Accordance With Current IES Published Procedures | |||||||||||||||||||
70 | 146 | 165 | 26 | 41.84 |
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
| Luminaire Input Watts = 33.0 |
|
|
| ||||||||||||
75 | 139 | 170 | 14 | 22.03 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
80 | 133 | 175 | 5 | 7.67 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
85 | 127 | 180 | 2 | .78 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
90122
Catalog No. FPO3/FP01, 26W Triple Tube, 1800 Lumens
0 |
|
51 |
|
102 | 60° |
| |
153 |
|
204 | 30° |
|
Report No. 3096FR
SC = .96
CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | ZONAL LUMENS AND PERCENTAGES |
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||||||||||
Angle Mean CP | Angle | Mean CP |
| Zone | Lumens |
| Zone | Lumens | %Lamp | %Fixt |
| Ceiling |
| 80% |
| 70% | 50% | 30% |
| |||||||
0 | 124 | 90 | 103 |
|
| 14.08 |
| 160.61 | 8.9 | 11.9 |
| Wall | 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | |||
5 | 139 | 95 | 104 | 53.67 |
| 270.4 | 15 | 20 |
| RCR | Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||||||
10 | 166 | 100 | 103 | 92.85 |
| 496.44 | 27.6 | 36.7 |
|
| 0 | 83 | 83 | 83 | 83 | 78 | 78 | 68 | 68 | 59 | 59 | 47 | ||||
15 | 190 | 105 | 101 | 109.8 |
| 851.27 | 47.3 | 62.9 |
|
| 1 | 73 | 68 | 64 | 60 | 64 | 57 | 55 | 50 | 48 | 43 | 34 | ||||
20 | 200 | 110 | 98 | 111.18 |
| 313.17 | 17.4 | 23.1 |
| Ratio | 2 | 65 | 58 | 52 | 47 | 54 | 45 | 47 | 39 | 40 | 34 | 26 | ||||
25 | 203 | 115 | 94 | 114.85 |
| 387.96 | 21.6 | 28.7 |
| 3 | 59 | 50 | 44 | 38 | 47 | 36 | 41 | 32 | 35 | 28 | 21 | |||||
|
|
| ||||||||||||||||||||||||
30 | 193 | 120 | 89 | 118.45 |
| 477.26 | 26.5 | 28.7 |
| Cavity | 4 | 54 | 44 | 37 | 32 | 41 | 30 | 36 | 27 | 31 | 23 | 18 | ||||
35 | 176 | 125 | 84 | 119.92 |
| 502.48 | 27.9 | 37.1 |
| 5 | 49 | 39 | 32 | 27 | 37 | 26 | 32 | 23 | 27 | 20 | 15 | |||||
|
|
| ||||||||||||||||||||||||
40 | 157 | 130 | 77 | 116.46 |
| 1353.75 | 75.2 | 100 |
| Room | 6 | 45 | 35 | 28 | 23 | 33 | 22 | 29 | 20 | 25 | 17 | 13 | ||||
45 | 143 | 135 | 70 | 90 | 113.2 |
| ** Efficiency = 75.1% ** |
| 7 | 42 | 31 | 25 | 20 | 30 | 19 | 26 | 17 | 22 | 15 | 11 | ||||||
50 | 134 | 140 | 63 | 109.73 |
|
|
|
|
|
|
| 8 | 39 | 28 | 22 | 18 | 27 | 17 | 23 | 15 | 20 | 13 | 10 | |||
55 | 128 | 145 | 55 | 93.24 |
|
|
|
|
|
|
| 36 | 26 | 20 | 16 | 24 | 24 | 15 | 22 | 13 | 19 | 12 | 9 | |||
60 | 123 | 150 | 47 | 120 | 74.79 |
|
|
|
|
|
|
| 10 | 34 | 24 | 18 | 14 | 22 | 13 | 20 | 12 | 17 | 11 | 8 | ||
65 | 119 | 155 | 39 | 54.55 |
|
|
|
|
|
| Determined In Accordance With Current IES Published Procedures | |||||||||||||||
70 | 116 | 160 | 31 | 140 | 34.75 |
|
|
|
|
|
|
|
|
|
| Luminaire Input Watts = 29.0 |
|
|
| |||||||
75 | 113 | 165 | 22 | 150 | 18.27 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
80 | 111 | 170 | 11 | 6.37 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
85 | 107 | 175 | 3 | 170 | .58 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
90 | 103 | 180 | 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalog No. IP03/IP01 150W T-4, 950 Lumens.
0 |
|
60 |
|
| 60° |
120 |
|
180 |
|
240 | 30° |
|
Report No. 3094FR
CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | ZONAL LUMENS AND PERCENTAGES |
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||||||||||
Angle Mean CP | Angle Mean CP |
| Zone | Lumens |
| Zone | Lumens | %Lamp | %Fixt |
| Ceiling |
| 80% |
| 70% | 50% | 30% |
| ||||||||
0 | 229 | 95 | 116 |
|
| 21.93 |
| 170.48 | 6.1 | 12.2 |
| Wall |
| 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | ||
5 | 226 | 100 | 115 |
| 64.18 |
| 263.56 | 9.4 | 18.8 |
| RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||||
10 | 236 | 105 | 113 |
| 84.37 |
| 467.85 | 16.7 | 33.4 |
|
| 0 | 55 | 55 | 55 | 55 | 51 | 51 | 38 | 44 | 38 | 38 | 30 | |||
15 | 234 | 110 | 110 |
| 93.08 |
| 838.84 | 30 | 59.8 |
|
| 1 | 48 | 45 | 42 | 40 | 42 | 37 | 31 | 32 | 31 | 28 | 21 | |||
20 | 204 | 115 | 106 |
| 94.43 |
| 350.51 | 12.5 | 25 |
| Ratio | 2 | 43 | 38 | 34 | 31 | 36 | 29 | 26 | 25 | 26 | 22 | 16 | |||
25 | 183 | 120 | 100 |
| 106.86 |
| 434.83 | 15.5 | 31 |
| 3 | 39 | 33 | 29 | 25 | 31 | 24 | 22 | 21 | 22 | 18 | 13 | ||||
30 | 165 | 125 | 94 |
| 118 |
| 535.51 | 19.1 | 31 |
| Cavity | 4 | 35 | 29 | 25 | 21 | 27 | 20 | 20 | 17 | 20 | 15 | 11 | |||
35 | 148 | 130 | 87 |
| 125.89 |
| 563.65 | 20.1 | 40.2 |
| 5 | 33 | 26 | 21 | 18 | 24 | 17 | 18 | 15 | 18 | 13 | 9 | ||||
|
|
|
| |||||||||||||||||||||||
40 | 135 | 135 | 79 |
| 127.1 |
| 1402.49 | 50.1 | 100 |
| Room | 6 | 30 | 23 | 19 | 15 | 22 | 15 | 16 | 13 | 16 | 11 | 8 | |||
45 | 125 | 140 | 71 |
| 90 | 126.29 |
| ** Efficiency = 50.1% ** |
| 7 | 28 | 21 | 17 | 13 | 20 | 13 | 15 | 11 | 15 | 10 | 7 | |||||
50 | 121 | 145 | 62 |
| 119.43 |
|
|
|
|
|
|
| 8 | 26 | 19 | 15 | 12 | 18 | 11 | 13 | 10 | 13 | 9 | 6 | ||
55 | 119 | 150 | 53 |
| 104.78 |
|
|
|
|
|
|
| 9 | 24 | 17 | 13 | 11 | 16 | 10 | 15 | 9 | 12 | 8 | 6 | ||
60 | 118 | 155 | 44 |
| 120 | 84.33 |
|
|
|
|
| 10 | 22 | 16 | 12 | 10 | 15 | 9 | 14 | 8 | 11 | 7 | 5 | |||
65 | 119 | 160 | 34 |
| 61.35 |
|
|
|
|
|
| Determined In Accordance With Current IES Published Procedures | ||||||||||||||
70 | 119 | 165 | 24 |
| 140 | 39.33 |
|
|
|
|
|
|
|
|
|
| Luminaire Input Watts = 150 |
|
|
| ||||||
75 | 119 | 170 | 12 |
| 150 | 20.57 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
80 | 119 | 175 | 3 |
| 6.98 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
85 | 116 | 180 | 1 |
| 170 | .59 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
90 | 115 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Job Informationv | Type: |
|
|
631 Airport Road, Fall River, MA 02720 • (508)
Lightolier is a Philips group brand