HP90 Surface HDB2SLW1FT
Page 2 of 2
Direct/Indirect Surface Mounted Fluorescent 2' x 2' with Acrylic Linear Prismatic Lens, 1 Lamp TT5
Model No. HDB2SLW1FTUNVPR
LER = FP - 64.1 IW - 38.4 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.74
Report Number: G2008239A
Catalog Number: HDB2SLW1FTUNVPR
Lamps: (1) F40 TT5
Luminaire: HP90 Surface 2' x 2' with linear prismatic lens.
Ballast:
Report is based on 3150 Lumens per lamp. Efficiency: 78.2%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 23.040 |
| 23.040 | |||||
Height of Side: |
|
| 2.280 |
| 2.280 | ||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 83 | 78 | 74 | 73 | 70 | 67 | 70 | 67 | 65 |
02 | 75 | 67 | 61 | 63 | 58 | 54 | 60 | 56 | 53 |
03 | 68 | 59 | 52 | 55 | 49 | 45 | 53 | 48 | 44 |
04 | 62 | 52 | 44 | 49 | 42 | 38 | 47 | 41 | 37 |
05 | 57 | 46 | 39 | 43 | 37 | 32 | 42 | 36 | 32 |
06 | 52 | 41 | 34 | 39 | 33 | 28 | 38 | 32 | 28 |
07 | 49 | 37 | 30 | 36 | 29 | 25 | 34 | 29 | 25 |
08 | 45 | 34 | 27 | 32 | 26 | 22 | 31 | 26 | 22 |
09 | 42 | 31 | 25 | 30 | 24 | 20 | 29 | 24 | 20 |
10 | 40 | 29 | 22 | 28 | 22 | 18 | 27 | 22 | 18 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 737 | 737 | 737 |
|
5 | 731 | 734 | 736 | 70 |
15 | 699 | 712 | 722 | 201 |
25 | 640 | 669 | 694 | 308 |
35 | 556 | 604 | 646 | 377 |
45 | 449 | 519 | 582 | 399 |
55 | 321 | 425 | 511 | 376 |
65 | 183 | 333 | 428 | 317 |
75 | 81 | 246 | 341 | 242 |
85 | 17 | 174 | 277 | 172 |
90 | 3 | 115 | 208 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
579 | 18.4 | 23.5 | |
957 | 30.4 | 38.8 | |
1723 | 55.0 | 70.3 | |
2463 | 78.2 | 100.0 | |
0000 | 0.0 | 000.0 | |
2463 | 78.2 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1687. | 1949. | 2186. |
55 | 1431. | 1895. | 2278. |
65 | 1043. | 1897. | 2439. |
75 | 667. | 2026. | 2808. |
85 | 267. | 2735. | 4353. |
Ordering Information
Explanation of Catalog Number. Example: HDB2SLW1FTUNVPR
HD
B
2
S
L
W
1
FT
|
|
|
|
|
|
|
| Reflector: | Lamp |
|
|
|
|
|
|
|
|
|
|
HP90 | Body Style: | Fixture | Ceiling |
| Type: | Acrylic Lens |
|
|
|
|
|
|
|
|
|
| |||
|
| Lamp: | Voltage: |
|
|
| Options: | ||||||||||||
Direct/Indirect | B = Surface | Width | Surface |
| White | Quantity |
| (By Others) | 120, 277 or |
|
|
| Add appropriate | ||||||
Surface | Mounted |
|
|
|
|
|
|
| 1=1 Lamp | FT= Twin Tube T5 |
|
|
| suffix to catalog | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| no., ie: (A) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ballast | Type: |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| <20THD <10THD | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 Lamp Elec. TT5 |
| SB* | IB** | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (40 Watt) |
| – | PR† | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 Lamp Elec. TT5 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (40 Watt) |
|
|
|
|
|
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A. Internal slow blow fusing: SUFFIX: C.
Electrical Wiring Options: Emergency Packs are only avalable for remote mounting. Consult factory.
For motion or light sensor: See Folio
Specifications
Performance: In an installation of 1 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .78. To reduce glare the average brightness at 65° shall not exceed 2439 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.
1 Lamp Elec. TT5 | BE* | – |
(50 Watt) | – | BF* |
1 Lamp Elec. TT5 | ||
(55 Watt) | PB | – |
LOL Dimming TT5 | ||
*Instant Start Standard. |
|
|
Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use IB or PR Ballast Code. †Program Rapid Start
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | Section 5/Folio |
Lightolier is a Philips group brand