Lightolier H9S1GLR228, H9S1GLR128 Ordering Information, Options/Accessories, Specifications

Page 2

HP90 Recessed Fluorescent H9S1GLR228 or 128

Page 2 of 2

Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens Static, 1 or 2 Lamp T5

Model No. H9S1GLR128UNVPG

LER = FP - 72.6 IW - 31.83 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.30

Report Number: G2006146

Catalog Number: H9S1GLR128UNVPG

Lamps: F28T5

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: QTP 2x28 T5-UNV-PSN

Report is based on 2750 Lumens per lamp.

Efficiency: 84.2%

 

 

CIE Type-Direct-Indirect

 

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.760

11.760

COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

92

88

85

83

80

78

80

78

76

02

84

77

72

73

69

65

70

67

63

03

77

68

62

64

59

55

62

58

54

04

70

61

53

57

52

47

55

50

46

05

65

54

47

52

45

41

50

45

40

06

6-

49

42

47

40

36

45

40

35

07

56

44

37

42

36

32

41

36

32

08

52

41

34

39

33

28

38

32

28

09

48

37

30

36

30

26

35

29

26

10

45

34

28

33

27

23

32

27

23

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 2329. 2060. 2185.

55 2121. 1953. 2020.

65 1794. 1717. 1736.

75 1247. 1354. 1322.

85 538. 570. 570.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

832

832

832

 

5

821

841

860

81

15

796

862

879

240

25

752

797

798

364

35

690

680

653

423

45

597

528

560

425

55

441

406

420

366

65

261

263

266

261

75

117

127

124

134

85

17

18

18

22

90

2

2

2

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

685

24.9

29.6

00-040

1108

40.3

47.8

00-060

1899

69.1

82.0

00-090

2316

84.2

100.0

90-180

0000

0.0

000.0

00-180

2316

84.2

100.0

Model No. H9S1GLR228UNVPG

LER = FP - 77.2 IW - 63.31 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.11

Report Number: G2006140

Catalog Number: H9S1GLR228UNVPG

Lamps: F28T5

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: QTP2X28T5/UNV

Report is based on 2750 Lumens per lamp. Efficiency: 88.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.760

 

11.760

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

97

93

89

87

85

82

84

82

80

02

89

81

75

77

72

68

74

70

67

03

81

72

64

68

62

57

65

60

56

04

74

63

56

60

54

49

58

53

48

05

68

57

49

54

47

42

52

46

42

06

63

51

43

49

42

37

47

41

37

07

58

46

38

44

37

33

43

37

32

08

54

42

35

40

34

29

39

33

29

09

51

39

31

37

31

26

36

30

26

10

47

36

29

34

28

24

33

28

24

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4245.

4748.

4822.

55

3958.

4391.

4276.

65

3505.

3851.

3542.

75

2729.

3046.

2665.

85

1203.

1329.

1203.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1661

1661

1661

 

5

1643

1659

1678

158

15

1581

1654

1725

468

25

1466

1621

1692

737

35

1303

1470

1512

902

45

1088

1217

1236

922

55

823

913

889

793

65

537

590

558

569

75

256

283

250

291

85

38

42

38

50

90

3

4

3

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1364

24.8

27.9

00-040

2266

41.2

46.3

00-060

3981

72.4

81.4

00-090

4891

88.9

100.0

90-180

0000

0.0

000.0

00-180

4891

88.9

100.0

Ordering Information

Explanation of Catalog Number. Example: H9S1GLR228UNVPG

S

1

G

L

R

28

 

 

 

 

 

 

 

 

 

 

Reflector:

Lamp

 

 

HP90

Body Style:

Fixture

Ceiling

 

Type:

Acrylic Lens

 

 

 

Lamp:

Direct/Indirect

S = Static

Width

Fits both

 

Specular

Quantity

(By Others)

Recessed

 

 

Standard Grid

 

Aluminum

1=1 Lamp

28=T5 28W

 

 

 

 

 

and

 

 

2=2 Lamp

(Nominal 48")

 

 

 

 

 

Slot Grid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H9

 

Standard HP90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HY

 

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HN

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

 

 

 

Options/Accessories

Voltage:

 

 

 

 

 

 

 

 

 

Options:

120, 277 or

 

 

 

Add appropriate

UNV=120-277

 

 

 

suffix to catalog

 

 

 

 

 

no., ie: (GLR)

 

Ballast Type:

 

 

 

 

 

 

<20THD <10THD

1 or 2 Lamp Elec. T5

PI

(28 Watt)

 

PG ††

1 or 2 Lamp Elec. T5

(28 Watt)

 

 

 

†Instant Start (120, 277 or UNV)

 

 

 

††Program Rapid Start (UNV only)

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK91X4.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .93. To reduce glare the average brightness at 65° shall not exceed 3851 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.1%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 5/Folio M32-20

Image 2
Contents Exposed t-grid ceiling Earthquake standards FeaturesMounting Methods Exposed slot t-grid ceiling Fully enclosed lamp compartmentOrdering Information Options/AccessoriesSpecifications