HP90 Recessed Fluorescent H9S2GLR1FT
Page 2 of 2
Model No. H9S2GLR1FTUNVPR
LER = FP - 61.2 IW - 37.55 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.92
Report Number: G2006149
Catalog Number: H9S2GLR1FTUNVPR
Lamps: F40BX/SPX30/IS
Luminaire: HP90 2' x 2' with linear prismatic lens.
Ballast: 
Report is based on 3150 Lumens per lamp. Efficiency: 72.9%
CIE   | 
  | 
  | 
  | 
  | |||||
Plane:  | 
  | 
  | 
  | 
  | 
 | 
  | 
 | ||
Spacing Criteria:  | 
  | 
  | 1.2  | 
  | 
  | 1.2  | |||
Shielding Angles:  | 
  | 
  | 90  | 
  | 
  | 90  | |||
Plane:  | 
  | 
  | 
  | 
  | 
  | ||||
Luminous Length:  | 
  | 23.760  | 
  | 23.760 | |||||
COEFFICIENTS OF UTILIZATION –  | 
  | 
  | |||||||
ZONAL CAVITY METHOD. EFFECTIVE  | 
  | ||||||||
FLOOR CAVITY REFLECTANCE 0.200  | 
  | ||||||||
RC  | 
  | 80  | 
  | 
  | 50  | 
  | 
  | 30  | 
  | 
RW  | 70  | 50  | 30  | 50  | 30  | 10  | 50  | 30  | 10  | 
01  | 80  | 76  | 73  | 71  | 69  | 67  | 69  | 67  | 65  | 
02  | 73  | 67  | 62  | 63  | 59  | 56  | 60  | 57  | 54  | 
03  | 66  | 59  | 53  | 55  | 51  | 47  | 53  | 49  | 46  | 
04  | 61  | 52  | 46  | 49  | 44  | 40  | 48  | 43  | 40  | 
05  | 56  | 47  | 40  | 44  | 39  | 35  | 43  | 38  | 40  | 
06  | 52  | 42  | 36  | 40  | 35  | 31  | 39  | 34  | 30  | 
07  | 48  | 38  | 32  | 37  | 31  | 27  | 36  | 31  | 27  | 
08  | 45  | 35  | 29  | 34  | 28  | 24  | 33  | 28  | 24  | 
09  | 42  | 32  | 26  | 31  | 26  | 22  | 30  | 25  | 22  | 
10  | 39  | 30  | 24  | 29  | 24  | 20  | 28  | 23  | 20  | 
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.  | |||
45  | 2174.  | 2011.  | 2049.  | 
55  | 1914.  | 1789.  | 1976.  | 
65  | 1494.  | 1611.  | 2065.  | 
75  | 1029.  | 1580.  | 2068.  | 
85  | 598.  | 765.  | 598.  | 
  | 
  | 
  | 
  | Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens  | |
  | 
  | 
  | 
  | 
  | Static, 1 Lamp TT5 | 
CANDELA DISTRIBUTION0  | 
  | 
  | 
  | ||
  | 0.0  | 45.0  | 90.0  | FLUX | 
  | 
0  | 876  | 876  | 876  | 
  | 
  | 
5  | 868  | 872  | 876  | 83  | 
  | 
15  | 836  | 841  | 845  | 238  | 
  | 
25  | 776  | 776  | 772  | 357  | 
  | 
35  | 685  | 665  | 646  | 416  | 
  | 
45  | 560  | 518  | 528  | 410  | 
  | 
55  | 400  | 373  | 413  | 348  | 
  | 
65  | 230  | 248  | 318  | 260  | 
  | 
75  | 97  | 149  | 195  | 155  | 
  | 
85  | 19  | 24  | 19  | 31  | 
  | 
90  | 2  | 2  | 2  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT | 
678  | 21.5  | 29.5  | |
1093  | 34.7  | 47.6  | |
1851  | 58.8  | 80.6  | |
2296  | 72.9  | 100.0  | |
0000  | 0.0  | 000.0  | |
2296  | 72.9  | 100.0  | 
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR1FTUNVPR
S
2
G
L
R
1
FT
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Reflector:  | Lamp  | 
  | 
  | 
HP90  | Body Style:  | Fixture  | Ceiling  | 
  | Type:  | Acrylic Lens  | 
  | 
  | |||||
  | Lamp: | ||||||||||||
Direct/Indirect  | S = Static  | Width  | Fits both  | 
  | Specular  | Quantity  | (By Others)  | ||||||
Recessed  | 
  | 
  | Standard Grid  | 
  | Aluminum  | 1=1 Lamp  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | and  | 
  | 
  | 
  | 
  | 
  | |||
  | 
  | 
  | 
  | 
  | Slot Grid  | 
  | 
  | 
  | 
  | 
  | |||
H9  | 
  | Standard HP90  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
HY  | 
  | 
  | For NYC Code – I.B.E.W. Manufactured  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
HN  | 
  | For NYC Code – Local 3 Manufactured  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio 
Voltage:  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Options:  | |||
120, 277 or  | 
  | 
  | Add appropriate  | |||
  | 
  | suffix to catalog  | ||||
  | 
  | 
  | 
  | 
  | no., ie: (GLR)  | |
  | 
  | Ballast Type: | 
  | 
  | ||
  | 
  | 
  | 
  | <20THD <10THD  | ||
1 Lamp Elec. TT5  | 
  | 
  | SB*  | IB**  | ||
(40 Watt)  | 
  | 
  | –  | PR†  | ||
1 Lamp Elec. TT5  | 
  | 
  | ||||
(40 Watt)  | 
  | 
  | BE*  | 
  | 
  | |
1 Lamp Elec. TT5  | 
  | 
  | 
  | –  | ||
(50 Watt)  | 
  | 
  | –  | BF*  | ||
1 Lamp Elec. TT5  | 
  | 
  | ||||
(55 Watt)  | 
  | 
  | PB  | 
  | –  | |
LOL Dimming TT5  | 
  | 
  | 
  | |||
*Instant Start Standard.  | 
  | 
  | ||||
Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start
Specifications
Performance: In an installation of 1 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .96. To reduce glare the average brightness at 65° shall not exceed 2617 candelas per square meter. To control veiling reflections, luminaire output in the 
Materials: Chassis parts are 
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information | Type: | 
  | 
  | 
Lightolier a Genlyte company  | www.lightolier.com  | 
Technical Information: (978)   | |
631 Airport Road, Fall River, MA 02720 • (508)   | |
We reserve the right to change details of design, materials and finish.  | |
© 2006 a Genlyte company  | Section 5/Folio   |