READ AND UNDERSTAND THESE INSTRUCTIONS |
|
|
|
| |
INSTRUCTION SHEET NO. |
| ||||
BEFORE INSTALLING LUMINAIRE. |
|
|
|
|
|
| IS:1000LV |
| |||
installation. To prevent electric shock, turn off electricity at main power supply before proceeding. |
|
| |||
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. |
|
|
|
|
|
To assure full compliance with local codes and regulations, check with your local electrical inspector before |
|
|
|
|
|
Retain these instructions for maintenance reference. |
|
|
|
|
|
|
|
|
|
| |
| B0607 |
| Page 1 of 2 |
|
INSTALLATION PROCEDURE FOR: LYTECASTER® 1000LV, 1000LVE1, & 1000LVE2 LOW VOLTAGE
CAUTION: USE ONLY WITH REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
CAUTION: BEFORE INSTALLING
WARNING— (RISK OF FIRE) DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OR WIRING COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT.
1.FRAME- IN AND WIRE-IN (Fig. A)
Fasten MOUNTING FRAME to wood joist. Line up bottom edge of ADJUSTABLE MOUNTING BAR with bottom of wood joist (Fig. E). Wire to supply leads. (For Cable, use
NOTE: ADJUSTABLE MOUNTING BARS can be extended for 24” mounting. For suspended ceiling, make certain that the bottom of MOUNTING FRAME is no higher than 1” above ceiling line (Fig. F)
2.CLOSE- IN (Fig. B)
Install plasterboard, or any other dry type ceiling, as required. Hole in board must be cut either on the ground or after the board is nailed to the ceiling, using MOUNTING FRAME opening as a cutting guide. (Make sure ROTO- CLIPS are rotated out of hole area to be cut.) (Fig. G).
*Lightolier also offers a hole cutter
3. |
| SEE SEPARATE |
| → | REFLECTOR TRIM |
4. | PUSH- UP (Fig. D). | INSTRUCTION SHEETS |
|
NOTE: For wet plaster ceiling, use Plaster Ring Accessory No.1959 (order separately).
SEE BACK PAGE FOR LAMPING INSTRUCTIONS
A COMPANY
631 Airport Road, Fall River, MA 02720