Lytecel Recessed Fluorescent LIS6G20LW154
6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T5, IES RP1 For VDT Areas
Model No. LIS6G20LW154120PG
LER = FP - 40.3 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.95 Report Number: G1206004
Catalog Number: LIS6G20LW154120PG
Lamp: F54 T5HO
Luminaire: 6" wide Troffer with semi- specular louver and white reflector. Ballast: Advance ICN-2S54
Report is based on 4400 Lumens per lamp. Efficiency: 54.9%
CIE Type-Direct-Indirect | | | | |
Plane: | | | | | 0-Deg | | 90-Deg |
Spacing Criteria: | | | 1.2 | | | 1.6 |
Shielding Angles: | | | 90 | | | 90 |
Plane: | | | | | 0-Deg | | 90-Deg |
Luminous Length: | | 47.943 | | 5.816 |
COEFFICIENTS OF UTILIZATION – | | |
ZONAL CAVITY METHOD. EFFECTIVE | |
FLOOR CAVITY REFLECTANCE 0.20 | |
RC | | 80 | | | 50 | | | 30 | |
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 61 | 60 | 58 | 56 | 55 | 54 | 54 | 53 | 52 |
2 | 57 | 54 | 51 | 51 | 49 | 47 | 49 | 48 | 46 |
3 | 53 | 49 | 45 | 47 | 44 | 42 | 45 | 43 | 41 |
4 | 50 | 44 | 40 | 42 | 39 | 37 | 41 | 38 | 36 |
5 | 46 | 40 | 36 | 39 | 35 | 33 | 38 | 35 | 32 |
6 | 43 | 37 | 32 | 35 | 32 | 29 | 34 | 31 | 29 |
7 | 40 | 33 | 29 | 32 | 29 | 26 | 32 | 28 | 26 |
8 | 37 | 31 | 27 | 30 | 26 | 24 | 29 | 26 | 23 |
9 | 35 | 28 | 24 | 27 | 24 | 21 | 27 | 24 | 21 |
10 | 33 | 26 | 22 | 25 | 22 | 19 | 25 | 22 | 19 |
| | | | | | | | | |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | 0-DEG. 45-DEG. 90-DEG. |
45 | 4954. | 6726. | 3485. |
55 | 3605. | 2128. | 1068. |
65 | 264. | 401. | 278. |
75 | 63. | 84. | 135. |
85 | 41. | 69. | 124. |
CANDELA DISTRIBUTION
| 0.0 | | 45.0 | 90.0 | FLUX |
0 | 1040 | | 1040 | 1040 | | |
5 | 1059 | | 1075 | 1113 | 102 |
15 | 978 | | 1069 | 1124 | 302 |
25 | 900 | | 1081 | 1412 | 514 |
35 | 792 | | 1193 | 1432 | 711 |
45 | 630 | | 856 | 443 | 523 |
55 | 372 | | 220 | 110 | 227 |
65 | 20 | | 30 | 21 | 29 |
75 | 3 | | | 4 | | 6 | | 5 |
85 | 1 | | | 1 | | 2 | | 2 |
90 | 0 | | | 1 | | 1 | | |
| | | | | | | |
TYPICAL V.C.P.'s | | | | | | | |
| | | | |
| | | Mounting Height | |
| | Lengthwise Crosswise |
Room | Luminaires | Luminaires |
Size | 0 Deg Plane | 90 Deg Plane |
| 8.5 | 10 | 8.5 | 10 | 8.5 | 10 | 8.5 | 10 |
30x30 | 89 | 85 | 84 | 76 | 96 | 93 | 92 | 84 |
40x40 | 89 | 86 | 85 | 81 | 96 | 93 | 93 | 87 |
60x30 | 80 | 86 | 85 | 79 | 96 | 93 | 92 | 85 |
60x60 | 89 | 86 | 84 | 81 | 96 | 94 | 93 | 88 |
100x100 | 89 | 86 | 84 | 82 | 96 | 95 | 94 | 88 |
| | | |
ZONAL LUMEN SUMMARY | | | |
| | | |
ZONE | LUMENS | % LAMP | % FIXT |
00-030 | 918 | | | 20.9 | | 38.0 |
00-040 | 1629 | | | 37.0 | | 67.5 |
00-060 | 2379 | | | 54.1 | | 98.5 |
00-090 | 2414 | | | 54.9 | | 100.0 |
90-180 | 0000 | | | 0.0 | | 000.0 |
00-180 | 2414 | | | 54.9 | | 100.0 |
Model No. LIS6G20PW154120PG
LER = FP - 43.4 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.53 Report Number: G1206005
Catalog Number: LIS6G20PW154120PG
Lamps: F54 T5HO
Luminaire: 6" wide Troffer with specular louver and white reflector.
Ballast: Advance ICN-2S54
Report is based on 4400 Lumens per lamp.
Efficiency: 58.2% | | | | | | |
CIE Type-Direct-Indirect | | | | |
Plane: | | | | | 0-Deg | | 90-Deg |
Spacing Criteria: | | | 1.2 | | | 1.6 |
Shielding Angles: | | | 90 | | | 90 |
Plane: | | | | | 0-Deg | | 90-Deg |
Luminous Length: | | 47.943 | | 5.816 |
COEFFICIENTS OF UTILIZATION – | | |
ZONAL CAVITY METHOD. EFFECTIVE | |
FLOOR CAVITY REFLECTANCE 0.20 | |
| | | | | | | | | |
RC | | 80 | | | 50 | | | 30 | |
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 65 | 63 | 61 | 60 | 58 | 57 | 57 | 56 | 55 |
2 | 61 | 57 | 54 | 54 | 52 | 50 | 52 | 51 | 49 |
3 | 57 | 52 | 48 | 49 | 46 | 44 | 48 | 45 | 43 |
4 | 53 | 47 | 43 | 45 | 41 | 39 | 44 | 41 | 38 |
5 | 49 | 43 | 38 | 41 | 37 | 34 | 40 | 37 | 34 |
6 | 45 | 39 | 34 | 37 | 34 | 31 | 36 | 33 | 30 |
7 | 42 | 35 | 31 | 34 | 30 | 28 | 33 | 30 | 27 |
8 | 39 | 32 | 28 | 31 | 28 | 25 | 31 | 27 | 25 |
9 | 37 | 30 | 25 | 29 | 25 | 22 | 28 | 25 | 22 |
10 | 35 | 28 | 23 | 27 | 23 | 20 | 26 | 23 | 20 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | 0-DEG. 45-DEG. 90-DEG. |
45 | 5251. | 7583. | 3387. |
55 | 4318. | 2106. | 923. |
65 | 10. | 397. | 242. |
75 | 14. | 75. | 159. |
85 | 45. | 103. | 192. |
CANDELA DISTRIBUTION
| 0.0 | | 45.0 | 90.0 | FLUX |
0 | 1052 | | 1052 | 1052 | | |
5 | 1082 | | 1101 | 1094 | 103 |
15 | 1029 | | 1102 | 1130 | 306 |
25 | 927 | | 1090 | 1491 | 532 |
35 | 829 | | 1350 | 1617 | 782 |
45 | 668 | | 965 | 431 | 568 |
55 | 446 | | 217 | 95 | 244 |
65 | 1 | | 30 | 18 | 20 |
75 | 1 | | | 3 | | 7 | | 4 |
85 | 1 | | | 2 | | 3 | | 2 |
90 | 0 | | | 1 | | 1 | | |
| | | | | | | |
TYPICAL V.C.P.'s | | | | | | | |
| | | | |
| | | Mounting Height | |
| | Lengthwise Crosswise |
Room | Luminaires | Luminaires |
Size | 0 Deg Plane | 90 Deg Plane |
| 8.5 | 10 | 8.5 | 10 | 8.5 | 10 | 8.5 | 10 |
30x30 | 87 | 76 | 78 | 75 | 96 | 93 | 93 | 84 |
40x40 | 87 | 76 | 78 | 79 | 97 | 93 | 93 | 87 |
60x30 | 87 | 76 | 78 | 79 | 96 | 93 | 93 | 85 |
60x60 | 88 | 77 | 79 | 79 | 96 | 94 | 94 | 88 |
100x100 | 88 | 77 | 79 | 79 | 95 | 94 | 95 | 89 |
| | | |
ZONAL LUMEN SUMMARY | | | |
| | | |
ZONE | LUMENS | % LAMP | % FIXT |
00-030 | | 942 | | | 21.4 | | 36.8 |
00-040 | 1724 | | | 39.2 | | 67.3 |
00-060 | 2536 | | | 57.6 | | 99.0 |
00-090 | 2563 | | | 58.2 | | 100.0 |
90-180 | 0000 | | | 0.0 | | 000.0 |
00-180 | 2942 | | | 51.6 | | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: LIS6G20LW154120PG
| | | | | | | | | | | | | | | | | | | | | | |
| | LI: | Body Style: | Fixture | Ceiling Type: | Number of | Louver Finish: | | | | Lamp | | Lamp Fixture | Voltage: | | | Options: |
| | Lytecel 6" | A =Air Return | Width | G = 9/16" or | Cells: | L=Low | | | | Quantity: | | Length: | | Add appropriate |
| | | | | | 120, 277 or | |
| | | S =Static | | 15/16"Grid | 1 row of | Iridescence | | | | (By others) | | 28=T5 | | suffix to catalog |
| | | | | | | | UNV=120-277 | |
| | | | | T = Slot Grid | 20 cells | Semi-specular | | | | 1=1 Lamp | | 54=T5HO | | no, ie: (GLR) |
| | | | | | | | | | | |
| | | | | A = 9/16" Tegular | | | P=Low | | | | | | | (Nominal 48") | | | | | |
| | | | | | | | | | | | | | | | |
LI | Standard Lytecel | | | Grid | | | Iridescence | | | | | | | | Ballast | Type: | |
| | | | | | | | | | | |
| | | | | D = 15/16" Tegular | | | Specular | | | | | | | | | | <20THD | <10THD |
| | | | | | | | | | | | | | | |
LN | For NYC Code – Local 3 Manufactured | | Grid | | | | | Reflector: | | | 1 Lamp 28w Elec. T5 | – | PI† |
| | | | | | | | |
| | | | | | | | | | W=White Reflector | | | 1 Lamp 28w Elec. T5 | – | PG†† |
| | | | | | | | | | | | | | | | | | 1 Lamp 54w Elec. T5 | – | PG†† |
| | | | | | | | | | | | | | | | | | †Instant Start (120, 277 or UNV) |
| | | | | | | | | | | | | | | | | | ††Program Rapid Start (UNV only) |
Options/Accessories | | | | | | | | | | | | | | | DA=DALI digital addressable dimming |
| | | | | | | Specifications (continued) | | | |
Access Plate: Top Wiring access plate is shipped with fixture as standard. When | | | |
access plates are required in advance for wiring convenience, specify separately. | Finish: Louver—specular or semi-specular low iridescence pre-anodized |
Order Catalog Number: ACP5 CSP. | | | | | | | | reflector sheet. Reflector: White baked polyester enamel reflector. Chassis |
Electrical/Wiring Options: Consult factory. | | | | | | | exterior—black baked polyester enamel. | | | |
EM Pack or Dimming Ballast: Consult factory. | | | | | | | Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If |
Fusing: Internal fast-blow fusing. Suffix: GLR. | | | | | | | K.O. is within 3" of ballast, use wire suitable for at least 90°. | |
| Internal slow-blow fusing. Suffix: GMF. | | | | | | | Labels: I.B.E.W./UL and ULc Listed. | | | |
Chicago Plenum: Suffix: CP. | | | | | | | | This product may have a mercury containing lamp. Manage in accord with |
| | | | | | | | | | | Disposal Laws. See: www.lamprecycle.org | | | |
Specifications
Performance: In an installation of 1 lamp 54W semi-specular luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 89 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 3605. Candelas at Nadir (0°) not to exceed 1040.
Air Handling-(LIA) side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak® or equal).
| Job Information | Type: | |
| |
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company | Section 2/Folio G07-38 |