Lytecel 6 LIA6GPNXR128 or 228
Page 2 of 2
Model No. LIA6GPNXR128UNVPG
Recessed Lens Fluorescent, Static or Air Return 6" Width X 48" Length, 1 or 2 Lamp T5
Model No. LIA6GPNXR228UNVPG
LER = FP - 62.5 IW - 31.99 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $3.84 Report Number: G2008084
Catalog Number: LIA6GPNXR128UNVPG
Lamp: F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast:
Report is based on 2750 Lumens per lamp. Efficiency: 72.7%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.1 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 46.800 |
| 4.560 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 80 | 77 | 74 | 72 | 70 | 68 | 69 | 67 | 66 |
2 | 73 | 67 | 63 | 64 | 60 | 57 | 61 | 58 | 56 |
3 | 67 | 60 | 54 | 56 | 52 | 48 | 55 | 51 | 48 |
4 | 62 | 53 | 47 | 51 | 46 | 42 | 49 | 45 | 41 |
5 | 57 | 48 | 42 | 46 | 40 | 36 | 44 | 40 | 36 |
6 | 53 | 43 | 37 | 41 | 36 | 32 | 40 | 35 | 32 |
7 | 49 | 39 | 33 | 38 | 32 | 29 | 37 | 32 | 28 |
8 | 46 | 36 | 30 | 35 | 29 | 26 | 34 | 29 | 26 |
9 | 43 | 33 | 27 | 32 | 27 | 23 | 31 | 26 | 23 |
10 | 40 | 31 | 25 | 30 | 25 | 21 | 29 | 24 | 21 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 5627. | 4867. | 4497. |
55 | 5367. | 4304. | 3696. |
65 | 4913. | 3333. | 2508. |
75 | 3899. | 1851. | 1851. |
85 | 1749. | 1749. | 1499. |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 844 | 844 | 844 |
|
5 | 831 | 837 | 840 | 80 |
15 | 798 | 791 | 782 | 223 |
25 | 737 | 702 | 675 | 325 |
35 | 652 | 588 | 568 | 376 |
45 | 548 | 474 | 438 | 371 |
55 | 424 | 340 | 292 | 309 |
65 | 286 | 194 | 146 | 201 |
75 | 139 | 66 | 66 | 91 |
85 | 21 | 21 | 18 | 24 |
90 | 3 | 7 | 8 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
627 | 22.8 | 31.4 | |
1004 | 36.5 | 50.2 | |
1683 | 61.2 | 84.2 | |
2000 | 72.7 | 100.0 | |
0000 | 0.0 | 000.0 | |
2000 | 72.7 | 100.0 |
LER = FP - 56.4 IW - 56.21 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $4.25 Report Number: G2008075
Catalog Number: LIA6GPNXR228UNVPG
Lamp: (2) F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast:
Report is based on 2750 Lumens per lamp. Efficiency: 57.6%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.1 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 46.800 |
| 4.560 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 63 | 61 | 58 | 57 | 55 | 54 | 55 | 53 | 52 |
2 | 58 | 53 | 50 | 50 | 48 | 45 | 49 | 46 | 44 |
3 | 53 | 47 | 43 | 45 | 41 | 38 | 43 | 40 | 38 |
4 | 49 | 42 | 37 | 40 | 36 | 33 | 39 | 35 | 33 |
5 | 45 | 38 | 33 | 36 | 32 | 29 | 35 | 31 | 29 |
6 | 42 | 34 | 29 | 33 | 29 | 25 | 32 | 28 | 25 |
7 | 39 | 31 | 26 | 30 | 26 | 23 | 29 | 25 | 22 |
8 | 36 | 29 | 24 | 27 | 23 | 20 | 27 | 23 | 20 |
9 | 34 | 26 | 22 | 25 | 21 | 18 | 25 | 21 | 18 |
10 | 32 | 24 | 20 | 23 | 19 | 17 | 23 | 19 | 17 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 8943. | 7711. | 7167. |
55 | 8557. | 6823. | 5759. |
65 | 7868. | 5240. | 3865. |
75 | 2912. | 2805. | 2917. |
85 | 2916. | 2666. | 2499. |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1342 | 1342 | 1342 |
|
5 | 1322 | 1331 | 1337 | 126 |
15 | 1270 | 1256 | 1240 | 354 |
25 | 1172 | 1114 | 1070 | 516 |
35 | 1038 | 929 | 901 | 596 |
45 | 871 | 751 | 698 | 589 |
55 | 676 | 539 | 455 | 488 |
65 | 458 | 305 | 225 | 317 |
75 | 225 | 100 | 104 | 145 |
85 | 35 | 32 | 30 | 37 |
90 | 4 | 11 | 13 |
|
|
| |||
ZONAL LUMEN SUMMARY |
| |||
|
|
| ||
ZONE | LUMENS % LAMP | % FIXT | ||
996 |
| 18.1 | 31.4 | |
1593 |
| 29.0 | 50.3 | |
2670 |
| 48.5 | 84.3 | |
3168 |
| 57.6 | 100.0 | |
0000 |
| 0.0 | 000.0 | |
3168 |
| 57.6 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: LIA6GPNXR128UNVPG
6
|
|
|
|
|
|
|
|
Lytecel | Body Style: | Fixture | Ceiling Type: |
| Lens | Style: | |
| A =Air Return | Width 6" | G = 9/16" or | PN = .08 White | |||
| S =Static |
| 15/16"Grid |
| Acyrlic | ||
|
|
| T = Slot Grid | VA = .095 Virgin |
X
R
Lamp
Quantity:
(By others)
1=1 Lamp
28
Lamp Fixture
Length:
28=T5 (Nominal 48")
|
|
| - |
|
|
| |
UNV |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Voltage: |
|
| Options: | ||||
| Add appropriate | ||||||
120, 277 or |
| ||||||
| suffix to catalog | ||||||
| |||||||
|
| no, ie: (A) | |||||
|
|
|
|
|
D = 9/16" Tegular | Acyrlic |
Grid | KA = .156 Virgin |
Reflector:
2=2 Lamps
LI | Standard Lytecel | Acyrlic |
|
|
|
LN | For NYC Code – Local 3 Manufactured |
|
|
|
Options/Accessories
Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP.
Electrical/Wiring Options: Consult factory.
EM Pack or Dimming Ballast: Consult factory.
Fusing: Internal
Internal
Chicago Plenum: Suffix: C.
W=Miro aluminum
Reflector
Ballast Type: | <10THD | |
1 or 2 Lamp 28w Elec. T5 | ||
PI†† | ||
1 or 2 Lamp 28w Elec. T5 | PG†† |
††Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only) DA=DALI digital addressable dimming.
Specifications (continued)
Finish: Reflector: 95% reflective Miro aluminum reflector. Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications
Performance: In an installation of 1 lamp 28W luminaire in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77 with a spacing to mounting ratio of 1.1 perpendicular to the lamps. Air Handling- Side air slots for air return.
Materials: Chassis parts are 20 gauge cold rolled steel.
Lightolier is a Philips group brand
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | Section 1A/Folio |