4. Test Information

Test Parameters

 

Parameters

Actual

Parameters

Actual

 

 

 

 

 

 

Ambient temperature

25.8 (℃)

Test Voltage

230V

 

 

 

 

 

 

Total harmonic distortion

1.2

Test Frequency

50Hz

 

 

 

 

 

 

Test Instrumentations

 

 

 

 

 

 

 

 

 

Test instrumentation

Model name

Manufacture

Expire date of Calibration

 

 

 

 

 

 

Power meter

WT1800

Yokogawa

2017-03-20

 

 

 

 

 

 

Power Source

6560

Chroma

2016-10-04

 

 

 

 

 

 

 

 

 

 

Set-up and circuit for electrical testing

4. Reference for test method

-EN 62301 ed. 2.0; Household electrical appliances – Measurement of standby power

-IEC 62323 ed. 1.0; Desktop and notebook computers – Measurement of energy consumption

-ISO 7779 :2010; Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment

-US EPA "Test Method for calculating the Energy efficiency of single voltage External AC-DC and AC-AC Power Supplies

-ISO 9296:1988; Acoustics - Declared noise emission values of computer and business equipment

-

-