Lightolier LP-6 manual Performance, Fixture Lengths & Mounting Locations, Mounting Accessories

Page 2

Lighting Systems LP-6

1BHFPG -JOFBS1FSG-ZUFÜ DN 4FNJ1FSGPSBUFE-JHIU51FS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

ZONE 0

CANDLEPOWER

90

 

22

45

67

 

DEG.

 

CANDELAS

 

 

 

 

 

 

 

 

180

1231

1231

1231

1231

1231

 

175

1228

1238

1241

1275

1261

 

165

1184

1255

1310

1399

1401

 

155

1107

1249

1373

1548

1587

 

145

966

1187

1397

1663

1726

 

135

783

1074

1368

1717

1791

 

125

627

987

1374

1715

1667

 

115

425

863

1169

1258

1269

 

105

229

624

751

911

926

 

95

58

224

231

202

191

 

90

0

17

25

27

29

 

85

7

13

20

26

28

 

75

23

29

38

48

51

 

65

29

39

51

62

66

 

55

68

74

92

99

101

 

45

84

88

99

107

110

 

35

112

114

121

130

134

 

25

134

134

139

142

143

REPORT NO: LRL 200-10L

15

148

148

151

151

151

5

156

156

159

157

158

CAT NO: LP1B3T54U

0

156

156

156

156

156

LAMPS: 3 F28T5

 

 

 

 

 

 

LUMENS: 2900

Calculations are for 28 watt T5 lamps, for 54 watt

EFFICIENCY: 76.9%

 

COEFFICIENTS OF UTILIZATION

%EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

50

 

 

 

 

 

WALL REFLECTANCE

 

 

 

 

 

70

50

30

70

50

30

50

30

10

 

 

 

 

 

 

 

 

 

 

 

 

RATIO

0

75

75

75

64

64

64

46

46

46

2

62

57

52

53

49

45

35

33

31

 

1

68

65

62

58

56

54

40

38

37

CAVITY

3

56

50

44

48

43

39

31

28

26

4

51

44

38

44

38

33

27

24

22

 

5

47

39

33

40

34

29

24

21

19

ROOM

6

43

34

29

37

30

25

22

18

16

7

40

31

25

34

27

22

19

16

14

 

8

36

28

22

31

24

19

17

14

12

 

9

34

25

20

29

22

17

16

13

11

 

10

31

23

18

27

20

15

14

11

9

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

DISTRIBUTION

 

 

 

 

 

 

 

 

Zone

 

Lumens

% Lamp

 

% Luminaire

0-90

 

463

 

 

5.3

 

 

6.9

 

 

90-180

6231

 

 

71.6

 

 

93.1

 

 

0-180

6694

 

 

76.9

 

 

100.0

 

 

T5 lamps multiply by 1.7

Fixture Lengths & Mounting Locations

 

 

 

 

 

 

 

 

 

 

 

 

 

4-Foot

 

8-Foot

 

12-Foot

 

End Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48” (121.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96” (243.84cm)

 

 

 

 

 

 

 

 

 

 

 

 

4-Foot Run

Module

 

Module

 

Module

 

4’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-Foot Run

 

 

1

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4’ 2” (127.00cm)

 

 

 

 

 

 

 

 

 

 

 

8’ 2” (248.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

144” (366.62cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-Foot Run

 

 

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-Foot Run

 

 

2

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20'-Foot Run

 

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12’ 2” (370.84cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24'-Foot Run

 

 

 

 

2

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96” (243.84cm)

 

 

 

 

 

 

 

96” (243.84cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16’

16’ 2” (492.76cm)

96” (243.84cm) 144” (366.62cm)

20’

20’ 2” (614.68cm)

144” (366.62cm) 144” (366.62cm)

24’

24’ 2” (736.60cm)

Cable/ Joiner

1

1

1

Mounting Accessories

Cable/Joiner Assembly

Standard Cable Length is 36” (91.44cm) Single Cable: LP1C36

Single Cable & Cord: LP1CC36

Single Cable & 4 Wire Cord: LP1CC36X4

Power Feed End Set

Ceiling Grid Kit CGK

Standard Cable Length is 36” (91.44cm)

Includes both Standard 1” (2.54cm)

Straight Cord: LP1EC36 4 Wire Cord*: LP1EC36X4

Tee Bar Clip & Slot Tee Clip

* use for dimming and/or emergency battery packs

 

Job Information Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY   We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Image 2
Contents Mountings FeaturesElectrical OptionsPower Feed End Set Ceiling Grid Kit CGK Mounting AccessoriesCable/Joiner Assembly Performance

LP-6 specifications

The Lightolier LP-6 is a premium lighting fixture renowned for its innovative design and effective lighting solutions tailored for various environments. This luminaire combines aesthetics with functionality, making it a popular choice among architects, designers, and builders.

One of the defining characteristics of the LP-6 is its versatility. Designed primarily for recessed applications, the LP-6 accommodates a range of settings, from commercial spaces to residential interiors. It seamlessly integrates into both ceilings and walls, providing a clean and unobtrusive appearance. The fixture is available in multiple finishes and colors, allowing for customization to match diverse design schemes.

The LP-6 features advanced LED technology, which offers energy efficiency without compromising brightness. With a high lumen output, the LP-6 ensures that spaces are illuminated adequately while consuming significantly less energy compared to traditional lighting options. This not only reduces energy costs but also promotes sustainability, making it an environmentally friendly choice.

Moreover, the LP-6 incorporates superior thermal management features. It is designed with heat sinks that dissipate heat effectively, ensuring longevity and reliability of the LED components. This technology enhances performance by preventing overheating, which can lead to reduced bulb life.

Another notable aspect of the LP-6 is its optical performance. It employs precision optics that provide a uniform light distribution. This technology minimizes glare and enhances visual comfort, making it ideal for environments where prolonged lighting is necessary. The fixture is also compatible with various dimming systems, allowing for greater control over lighting levels and moods.

In addition to its functional advantages, the LP-6 is built with durability in mind. Constructed from high-quality materials, the fixture is designed to withstand the wear and tear of everyday use. This robustness ensures a long service life, reducing the need for frequent replacements.

In summary, the Lightolier LP-6 is an exemplary lighting fixture that combines sleek design with cutting-edge technology. Its versatility, energy efficiency, advanced thermal management, superior optical performance, and durability make it a noteworthy choice for anyone looking to enhance their lighting experience. Whether illuminating a retail space, office, or home, the LP-6 stands out as a reliable and stylish solution.