Calculite® Incandescent Open Wall Washer P7006
Page 2 of 2 | 4 1/2" Aperture A19 |
|
| WALL |
|
WALL | WALL | WALL | WALL |
| WALL | INSIDE CORNER | DOUBLE |
| WASHER | WALLWASHER | WALLWASHER |
|
| Example: with multiple |
|
| clear cone units, using |
4' |
| 100W |
| 4' | 2' from wall and 4' on cen- |
| ter, (matching downlights | |
|
| |
3' |
| 4' on center), the illumina- |
| tion on the wall 3' down | |
14 f.c. |
| from the ceiling is 14 f.c. |
| beneath fixtures and 12 f.c. | |
12 f.c. |
| |
| between fixtures. | |
|
|
Footcandles on Wall from Multiple Units — Clear Cone, 100W A19
Distance from Ceiling (FT.)
Distance from Ceiling (FT.)
Units 2 Feet |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2' |
|
|
|
|
|
|
| 3' |
|
|
|
|
| 4' |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
From Wall |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 19 | 18 |
|
| 19 | 15 | 14 |
|
| 15 | 15 | 8 |
|
| 15 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
2 | 26 | 26 |
|
| 26 | 20 | 20 |
|
| 20 | 18 | 15 |
|
| 18 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
3 | 22 | 22 |
|
| 22 | 16 | 16 |
|
| 16 | 14 | 12 |
|
| 14 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
4 | 16 | 18 |
|
| 16 | 12 | 14 |
|
| 12 | 10 | 10 |
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
5 | 13 | 14 |
|
| 13 | 10 | 12 |
|
| 10 | 9 | 8 |
|
| 9 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
6 | 13 | 12 |
|
| 13 | 9 | 10 |
|
| 9 | 9 | 8 |
|
| 9 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
7 | 10 | 10 |
|
| 10 | 8 | 8 |
|
| 8 | 8 | 6 |
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
8 | 10 | 10 |
|
| 10 | 8 | 8 |
|
| 8 | 8 | 6 |
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
9 | 10 | 10 |
|
| 10 | 8 | 8 |
|
| 8 | 8 | 6 |
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
Units 3 Feet |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3' |
|
|
|
|
|
|
| 4' |
|
|
|
|
|
|
| 5' |
|
|
|
|
|
|
|
| 6' |
|
|
|
| |||||||||
From Wall |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 7 | 10 |
|
| 7 | 7 | 6 |
|
| 7 | 5 | 4 |
|
| 5 | 5 | 3 |
|
| 3 |
| |||||||||||||||||||||
2 | 13 | 12 |
|
| 13 | 11 | 8 |
|
| 11 | 9 | 8 |
|
| 9 | 9 | 6 |
|
| 9 |
| |||||||||||||||||||||
3 | 14 | 14 |
|
| 14 | 12 | 10 |
|
| 12 | 8 | 8 |
|
| 8 | 8 | 8 |
|
| 8 |
| |||||||||||||||||||||
4 | 13 | 14 |
|
| 13 | 11 | 8 |
|
| 11 | 8 | 8 |
|
| 8 | 7 | 8 |
|
| 7 |
| |||||||||||||||||||||
5 | 10 | 14 |
|
| 10 | 10 | 8 |
|
| 10 | 8 | 8 |
|
| 8 | 6 | 6 |
|
| 6 |
| |||||||||||||||||||||
6 | 9 | 12 |
|
| 9 | 9 | 6 |
|
| 9 | 7 | 6 |
|
| 7 | 5 | 6 |
|
| 5 |
| |||||||||||||||||||||
7 | 9 | 12 |
|
| 9 | 9 | 6 |
|
| 9 | 7 | 6 |
|
| 7 | 5 | 6 |
|
| 5 |
| |||||||||||||||||||||
8 | 9 | 10 |
|
| 9 | 9 | 6 |
|
| 9 | 7 | 6 |
|
| 7 | 5 | 6 |
|
| 5 |
| |||||||||||||||||||||
9 | 9 | 10 |
|
| 9 | 9 | 6 |
|
| 9 | 7 | 6 |
|
| 7 | 5 | 6 |
|
| 5 |
|
Footcandle values are averaged and rounded off and are based on a minimum of five units.
Conversion factors: 75W
Clear Cone, 100W A19
Candlepower Distribution | |
Wall Wash Side | Downlight Side |
For even wall washing use a | Downlight Spacing |
maximum of 2 to 1 spacing | Ratio = 1.3 |
(distance between fixture + |
|
distance to wall). |
|
Coefficients of Utilization
%Effective Ceiling Cavity Reflectance
|
|
| 80 |
|
|
| 50 |
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| % | Ceiling Reflectance |
|
|
| |||
|
| 50 | 30 | 10 |
| 50 | 30 | 10 |
| 50 | 30 | 10 |
| 1 | .62 | .60 | .59 |
| .58 | .57 | .56 |
| .54 | .53 | .53 |
Ratio | 2 | .58 | .55 | .53 |
| .55 | .53 | .52 |
| .51 | .50 | .49 |
3 | .54 | .51 | .49 |
| .51 | .49 | .48 |
| .49 | .48 | .47 | |
|
|
| ||||||||||
Cavity | 4 | .50 | .48 | .46 |
| .48 | .47 | .45 |
| .47 | .45 | .44 |
6 | .44 | .41 | .39 |
| .43 | .40 | .38 |
| .41 | .39 | .39 | |
Room | 5 | .48 | .44 | .42 |
| .46 | .43 | .41 |
| .44 | .42 | .41 |
8 | .38 | .35 | .32 |
| .37 | .34 | .32 |
| .36 | .33 | .32 | |
| 7 | .41 | .38 | .35 |
| .40 | .37 | .35 |
| .39 | .36 | .34 |
| 9 | .35 | .31 | .29 |
| .34 | .31 | .29 |
| .33 | .31 | .29 |
| 10 | .32 | .29 | .27 |
| .32 | .29 | .27 |
| .31 | .29 | .27 |
|
|
|
|
|
|
|
|
|
|
|
|
|
20% Floor Cavity Reflectance
Conversion Factors:
75W
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902