Lightolier Silhouette SE manual Performance, Fixture Lengths & Mounting Locations, Sample Run

Page 2

Lighting Systems Silhouette® SE

1BHFPG

-PVWFSFE*OEJSFDU%JSFDU-JHIU5QFS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

180˚

175˚

165˚

155˚

145˚

135˚

750

 

 

 

 

 

600

 

 

 

 

125˚

450

 

 

 

 

115˚

 

 

 

 

 

300

 

 

 

90˚

 

 

 

 

105˚

 

 

 

 

 

150

 

 

 

 

95˚

 

 

 

 

 

0

 

 

 

 

90˚

150

 

 

 

 

85˚

 

 

 

 

 

300

 

 

 

 

75˚

 

 

 

 

 

450

 

 

 

 

65˚

 

 

 

 

 

600

 

 

 

 

55˚

 

 

 

 

 

750

 

 

 

 

 

15˚

25˚

35˚

45˚

REPORT NO: LRL 299-1E

 

CAT NO: SE24I281WH

 

LAMPS: 2 F28T5

 

 

LUMENS: 2900

 

 

EFFICIENCY: 79.3%

 

 

 

CANDLEPOWER

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

ZONE

0

22

45

67

90

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

DEG.

 

CANDELAS

 

 

 

 

 

80

 

 

 

70

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

598

598

598

598

598

 

 

 

 

WALL REFLECTANCE

 

 

 

 

175

600

592

588

579

578

 

 

70

50

30

 

70

50

30

50

30

10

 

165

590

574

590

642

646

 

0

81

81

81

 

73

73

73

57

57

57

 

155

557

557

654

722

740

RATIO

1

74

71

68

 

66

64

61

50

48

47

145

496

555

673

730

754

2

68

63

58

 

61

56

53

45

42

40

135

409

515

623

730

760

CAVITY

3

63

56

50

 

56

50

46

40

37

35

125

330

452

612

796

808

4

57

50

44

 

51

45

40

36

33

30

115

220

348

648

847

898

 

5

53

45

39

 

47

40

35

33

29

26

105

122

312

578

670

698

ROOM

6

49

40

34

 

44

36

31

30

26

23

90

9

38

47

74

72

8

42

33

27

 

38

30

25

24

21

18

95

28

171

217

225

225

 

7

45

36

30

 

41

33

28

27

23

20

85

17

29

50

66

68

 

9

39

30

24

 

35

27

23

22

19

16

75

51

52

62

72

83

 

10

36

27

22

 

32

25

20

20

17

14

 

65

86

83

89

101

94

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

55

150

149

157

148

177

 

 

 

 

 

 

 

 

 

 

 

 

 

45

261

254

306

269

243

 

 

 

 

DISTRIBUTION

 

 

 

 

35

406

385

426

492

528

 

Zone

 

Lumens

 

% Lamp

 

% Luminaire

25

538

511

534

578

598

 

 

 

 

 

0-90

 

1331

 

 

22.9

 

 

28.9

 

 

15

640

623

619

623

624

 

 

 

 

 

 

 

 

 

90-180

 

3271

 

 

56.4

 

 

71.1

 

 

5

702

698

700

687

686

 

 

 

 

 

 

 

 

 

0-180

 

4602

 

 

79.3

 

 

100.0

 

 

0

709

709

709

709

709

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

Quick Calculator and Ceiling Brightness

 

2,000

 

FOOTCANDLE

 

 

 

20

30

 

50

70

 

100

 

 

 

 

 

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40 50

70

100

200

NUMBER OF FIXTURES REQUIRED

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to horizontal axis and read number of fixtures required.

Suspension Length

12"

18"

24"

Footlamberts Above Fixture

121

84.3

67.1

Footlamberts Between Fixtures

20.2

25.2

30.4

Ceiling Brightness Ratio

6.0

3.3

2.2

Reflectances of 80% ceiling, 50% walls and 20% floor. Light loss factor is .85, Room size is 50' x 50',

Run Spacing 10’. Ceiling Height 9’ to 12’. Values are taken from the center of the room.

Fixture Lengths & Mounting Locations

4-Foot Joiner

 

 

 

 

 

 

 

5/8” (1.59cm)

 

 

 

 

 

 

 

8-Foot Joiner

 

 

 

 

 

 

 

 

 

48” (121.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4” (3.18cm)

96” (243.84cm)

Sample Run

8-Foot Joiner

4-Foot Joiner

8-Foot Joiner

Cable

Power Feed

Assembly

End Set

96” (243.84cm)

48” (121.92cm)

96” (243.84cm)

 

20’ 1/8” (609.92cm)

Mounting & Joiner Block Accessories

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

4” (10.16cm)

8” (20.32cm)

4” (10.16cm)

3.4”

4”

(8.64cm)

(10.16cm)

Cable Assembly

Power Feed End Set

“L”Block with Suspension

“X” Block with Suspension

“T” Block with Suspension

SC36

SE36WH (white)

SL36WH (white)

SX36WH (white)

 

ST36WH (white)

 

SE36AL (aluminum)

SL36AL (aluminum)

SX36AL (aluminum)

 

ST36AL (aluminum)

Inline block available (SI36WH or SI36AL).

 

 

 

 

 

 

Job Information

Type:

 

 

 

 

 

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Image 2