Samsung AR18KPFNDWKNSG manual Shortening or extending the refrigerant pipes assembly pipe

Page 38

1.Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear.

2.Smooth the cut edges.

3.Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:

Outer diameter (mm)

Torque (N•m)

Torque (kgf•cm)

ø 6.35

14 to 18

140 to 180

 

 

 

ø 9.52

34 to 42

350 to 430

 

 

 

ø 12.70

49 to 61

500 to 620

 

 

 

ø 15.88

68 to 82

690 to 830

 

 

 

Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe)

 

 

Pipe cutter

 

 

 

Pipe

 

90°

Oblique

Rough

Burr

NOTE

If you want to shorten or extend the pipes, see Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe) on page 37.

4.Cut off the remaining foam insulation.

5.If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole.

The pipe should not project from the rear of the indoor unit.

The bending radius should be 100 mm or more.

6.Pass the pipe through the hole in the wall.

NOTE

The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test. For further details. see Step 4.1 Performing the gas leak tests on page 43.

CAUTION

Tighten the flare nut with a torque wrench according to specified method. If the flare nut is over- tightened, the flare may break and cause refrigerant gas leakage.

Do not box in or cover the pipe connection. All refrigerant pipe connection must be easily accessible and serviceable.

D

 

 

90°±2°

 

 

 

 

 

A

45°±2°

 

 

 

 

 

 

L

 

 

 

R 0.4 to 0.8

Pipe

Flare

D

 

 

 

 

 

 

(Unit: mm)

Outer diameter (D)

 

Depth (A)

Flare dimension (L)

ø 6.35

 

1.3

8.7 to 9.1

ø 9.52

 

1.8

12.8 to 13.2

ø 12.70

 

2.0

16.2 to 16.6

ø 15.88

 

2.2

19.3 to 19.7

 

 

 

Flare nut

Indoor outlet pipe

 

 

Connecting pipe

Outer diameter (mm)

Torque (N•m)

Torque (kgf•cm)

ø 6.35

 

14 to 18

140 to 180

ø 9.52

 

34 to 42

350 to 430

ø 12.70

 

49 to 61

500 to 620

ø 15.88

 

68 to 82

690 to 830

English 37

Installation

DB68-06031A-01_A5.indd 37

4/18/2017 8:59:59 AM

Image 38
Contents Saudi Arabia Airconditioner Contents Correct Disposal of This Product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Operation indicatorSingle user indicator DisplayAlthough HeatARJC/KC, Quiet, Virus Remote Control OverviewInserting batteries Operation modes Remote Control OperationControlling temperature Vertical air flow Controlling fan speedControlling air flow direction Horizontal air flow manualStep cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationHeating Operation Heat modeMode is running Fan mode Quick Smart FeaturesAuto mode Fast function Comfort functionBeep sound function Single user function Cool mode When the Single user function starts,Energy-Saving Operation Timed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning duration minutes Auto Cool, Cool, Dry Cleaning at a GlanceRunning Auto clean Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Does not work Setting the time Indicator blinks Problem Solution Cannot change the fanReplace the batteries in the remote control with new ones Check whether the drains are clean. Clean them regularlySafety Information on Installation InstallationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Minimum clearances for the outdoor unitUnpacking Checking and preparing accessories and toolsAccessories Unpacking the indoor unitTools General tools Optional accessoriesAccessories in the outdoor unit package Tools for test operationTaping the pipes, cables, and drain hose Drilling a hole through the wallDisassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Remove the cap screws, then the screwsConnecting the cables assembly cable ARJC/KCARHP/JP/KP/MPOptional Extending the power cable Install the drain hose Installing and connecting the drain hosePressing socket Incomplete wire Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Serviceable 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a window frameFix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board Fixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Can operate correctlyLeave the system in the standby mode Evacuating the airAdding refrigerant Performing the gas leak tests Installation InspectionRunning the Smart Install mode Error Blink Refrigerant flow Error indicator LED DisplayError between Blocking error OpenPumping down refrigerant Turn on th air conditioner and select Fast Cool modePerforming final check and trial operation Pumping down for removing the product
Related manuals
Manual 56 pages 56.79 Kb

AR18KPFNDWKNSG, AR18KPFNDWK/SG, AR12KPFNDWK/SG, AR24KPFNDWKNSG, AR12KPFNDWKXSG specifications

Samsung's AR series air conditioners, including models AR12KPFNDWKNSG, AR24KPFNDWK/SG, AR12HPFSDWK/SG, AR12KPFNDWKXSG, and AR24KPFNDWKNSG, represent a perfect blend of advanced technology, efficiency, and design, making them a vital component of modern home environments.

One of the standout features of these models is Samsung's Digital Inverter technology. This state-of-the-art system optimizes energy consumption by automatically adjusting the compressor speed depending on the cooling demand. As a result, these air conditioners not only provide powerful cooling when it's needed but also operate quietly and maintain energy efficiency, resulting in lower electricity bills.

Another notable characteristic is the Fast Cooling mode, which allows for rapid temperature adjustments. This is particularly advantageous during the sweltering summer months when immediate relief is desired. The AR series can quickly lower temperatures to provide comfort as soon as you enter the room.

These models also come equipped with Samsung's advanced filtration technology, which plays a significant role in maintaining indoor air quality. The air conditioners are designed with a multi-layer filtration system that traps dust, allergens, and other pollutants, creating a cleaner and healthier environment for occupants. This feature is increasingly essential, particularly for those with allergies or respiratory concerns.

The design of the AR series is sleek and modern, ensuring that they fit seamlessly into any interior decor. The front panel is smooth and simple, often available in neutral colors that allow it to blend effortlessly with various room styles. Furthermore, the compact form factor of these units makes them easy to install without compromising valuable floor space.

In terms of control, these air conditioners are user-friendly. They often come with a remote control for convenient operation from anywhere in the room, as well as smart features that enable control via smartphone apps. This compatibility with smart home systems provides added convenience for tech-savvy users.

Moreover, the models are designed with durability in mind. High-quality components and a robust build ensure that these air conditioners are built to last, handling the rigors of everyday use while minimizing maintenance needs.

In summary, the Samsung AR12KPFNDWKNSG, AR24KPFNDWK/SG, AR12HPFSDWK/SG, AR12KPFNDWKXSG, and AR24KPFNDWKNSG models epitomize modern air conditioning technology. With their efficient performance, advanced filtration, user-friendly controls, and stylish design, they cater to contemporary consumer needs while ensuring comfort and satisfaction.