Section 1A/Folio E60-34

SPECPLUS SPS2GFSVA432

Page 1 of 2

2'x4' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC, 4 LAMP, T8 OR T12

Features

5" deep body.

3-1/16" lamp to lens for better lamp obscuration.

81.2% efficient.

Clean contoured interior.

One-piece housing has ribbed construction for added strength.

Hemmed over side rails for maximum safety.

Fixture ends turned-in for safe handling.

Built-in earthquake clips (patent no. 5,072,344).

Slimline door frame with 1000 square inch lens opening.

Door jamb finished black on four sides for positive light stop.

True mitered corner steel lens frame.

Spring loaded rooster head latches.

18 gauge steel hinges.

Flat and regressed aluminum doors available.

MOUNTING METHODS

 

 

 

 

 

G

exposed T-grid ceiling.

 

 

(with flat aluminum frame)

 

 

 

 

1/4" max.

 

 

 

1-1/2" max.

 

 

24"

15/16"

 

 

or 1"

 

 

 

 

 

 

 

 

 

 

drywall kit (see options)

 

 

 

 

Support

 

 

Type “G”

(by others)

 

 

FIxture

 

 

Drywall Kit

 

(See Options)

 

Drywall

 

(by others)

Ceiling Opening

15/16"

24-5/16" x 48-5/16"

 

F

plaster ceiling/flanged.

Plaster

Opening

24-1/8"

1-1/8" min.

3-3/4" max.

13/16"

24-11/16"

exposed T-grid ceiling (with flat steel frame)

1/4" max.

1-1/2" max.

24"

15/16" or 1"

DIMENSIONS

5" (127mm)

 

24" (610mm)

 

 

 

 

6" (152mm)

2" x 2-1/2" access plate

 

with two K.O.s

(7/8" dia.)

39-1/4" (997mm)

47-31/32" (1218mm)

earthquake clip before installation

earthquake clip installed (lay-in grid)

Job Information

Type:

 

 

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

Lightolier a Genlyte Thomas Companywww.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 1