Model No. SKS2GPK2FTUNVIB (25 watt lamp)
2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp Twin Tube T5
Model No. SKS2GPK2FTUNVIB (40 watt lamp)
LER = FP - 64.0 IW - 59.4 BF - 0.92 Comparative yearly lighting energy cost per
1000 lumens = $3.75
Report Number: G2008207
Catalog Number: SKS2GPK2FTUNVIB
Lamps: (2) PL-L40/835/XEW/4P/RS/IS 25W
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly. Ballast: ICN-2TTP40-SC
Report is based on 2300 Lumens per lamp. Efficiency: 89.9%
CIE Type-Direct-Indirect | | | | |
Plane: | | | | | 0-Deg | | 90-Deg |
Spacing Criteria: | | | 1.2 | | | 1.4 |
Shielding Angles: | | | 90 | | | 90 |
Plane: | | | | | 0-Deg | | 90-Deg |
Luminous Length: | | 21.600 | | 21.600 |
COEFFICIENTS OF UTILIZATION – | | |
ZONAL CAVITY METHOD. EFFECTIVE | |
FLOOR CAVITY REFLECTANCE 0.200 | |
RC | | 80 | | | 50 | | | 30 | |
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 99 | 95 | 91 | 89 | 87 | 84 | 86 | 84 | 82 |
02 | 91 | 84 | 78 | 79 | 75 | 71 | 76 | 73 | 69 |
03 | 83 | 75 | 68 | 71 | 65 | 61 | 68 | 64 | 60 |
04 | 77 | 67 | 59 | 63 | 57 | 53 | 61 | 56 | 52 |
05 | 71 | 60 | 52 | 57 | 51 | 46 | 55 | 50 | 46 |
06 | 66 | 54 | 47 | 52 | 45 | 41 | 50 | 45 | 40 |
07 | 61 | 49 | 42 | 47 | 41 | 36 | 46 | 40 | 36 |
08 | 57 | 45 | 38 | 43 | 37 | 33 | 42 | 37 | 32 |
09 | 53 | 42 | 35 | 40 | 34 | 30 | 39 | 33 | 29 |
10 | 50 | 38 | 32 | 37 | 31 | 27 | 36 | 31 | 27 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1721 | 1721 | 1721 | |
5 | 1704 | 1705 | 1709 | 162 |
15 | 1613 | 1631 | 1658 | 462 |
25 | 1449 | 1520 | 1614 | 704 |
35 | 1229 | 1390 | 1548 | 863 |
45 | 921 | 1012 | 1025 | 773 |
55 | 595 | 653 | 623 | 569 |
65 | 337 | 367 | 348 | 364 |
75 | 171 | 176 | 161 | 188 |
85 | 32 | 45 | 25 | 46 |
90 | 0 | 0 | 0 | |
| | | | |
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
00-030 | 1328 | 28.9 | 32.1 |
00-040 | 2191 | 47.6 | 53.0 |
00-060 | 3537 | 76.9 | 85.5 |
00-090 | 4134 | 89.9 | 100.0 |
90-180 | 0000 | 0.0 | 000.0 |
00-180 | 4134 | 89.9 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | 0-DEG. 45-DEG. 90-DEG. |
45 | 4326. | 4753. | 4814. |
55 | 3445. | 3781. | 3607. |
65 | 2648. | 2884. | 2735. |
75 | 2194. | 2258. | 2066. |
85 | 1219. | 1715. | 953. |
LER = FP - 64.3 IW - 69.1 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $3.73
Report Number: G2008206
Catalog Number: SKS2GPK2FTUNVIB
Lamps: (2) PL-L40/835/RS/IS
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly. Ballast: ICN-2TTP40-SC
Report is based on 3300 Lumens per lamp. Efficiency: 76.5%
CIE Type-Direct-Indirect | | | | |
Plane: | | | | | 0-Deg | | 90-Deg |
Spacing Criteria: | | | 1.2 | | | 1.4 |
Shielding Angles: | | | 90 | | | 90 |
Plane: | | | | | 0-Deg | | 90-Deg |
Luminous Length: | | 21.600 | | 21.600 |
COEFFICIENTS OF UTILIZATION – | | |
ZONAL CAVITY METHOD. EFFECTIVE | |
FLOOR CAVITY REFLECTANCE 0.200 | |
RC | | 80 | | | 50 | | | 30 | |
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 84 | 81 | 78 | 76 | 74 | 72 | 73 | 71 | 69 |
02 | 77 | 71 | 66 | 67 | 63 | 60 | 65 | 62 | 59 |
03 | 71 | 63 | 57 | 60 | 55 | 51 | 58 | 54 | 51 |
04 | 65 | 56 | 50 | 54 | 48 | 44 | 52 | 47 | 44 |
05 | 60 | 51 | 44 | 48 | 43 | 39 | 47 | 42 | 38 |
06 | 56 | 46 | 39 | 44 | 38 | 34 | 43 | 38 | 34 |
07 | 52 | 42 | 35 | 40 | 35 | 31 | 39 | 34 | 30 |
08 | 48 | 38 | 32 | 37 | 31 | 27 | 36 | 31 | 27 |
09 | 45 | 35 | 29 | 34 | 29 | 25 | 33 | 28 | 25 |
10 | 42 | 33 | 27 | 31 | 26 | 23 | 31 | 26 | 22 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 2055 | 2055 | 2055 | |
5 | 2040 | 2040 | 2043 | 194 |
15 | 1937 | 1957 | 1986 | 554 |
25 | 1747 | 1826 | 1932 | 846 |
35 | 1482 | 1672 | 1859 | 1041 |
45 | 1131 | 1248 | 1276 | 956 |
55 | 736 | 808 | 772 | 703 |
65 | 420 | 459 | 435 | 454 |
75 | 218 | 222 | 207 | 240 |
85 | 48 | 66 | 40 | 65 |
90 | 0 | 0 | 0 | |
| | | | |
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
00-030 | 1593 | 24.1 | 31.5 |
00-040 | 2635 | 39.9 | 52.2 |
00-060 | 4294 | 65.1 | 85.0 |
00-090 | 5052 | 76.5 | 100.0 |
90-180 | 0000 | 0.0 | 000.0 |
00-180 | 5052 | 76.5 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | 0-DEG. 45-DEG. 90-DEG. |
45 | 5312. | 5861. | 5993. |
55 | 4261. | 4678. | 4470. |
65 | 3300. | 3607. | 3418. |
75 | 2797. | 2849. | 2656. |
85 | 1829. | 2515. | 1524. |
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK2FTUNVIB
Skyway | Body Style: | Fixture | Ceiling Type: | Side Lens: |
Recessed | S = Static | Width | G = Standard | P= Frost White |
Fluorescent | A = Air | | Grid | Acrylic Lens |
| | | | T = Slot Grid | |
| | | | | |
SK | Standard Skyway | | | |
| | | | |
SY | | For NYC Code – I.B.E.W. Manufactured | | |
| | | | |
NK | For NYC Code – Local 3 Manufactured | | |
| | | |
| | | | | |
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
Center Lens: | Lamp | | | | |
| Lamp: |
K= Pattern 19 | Quantity | | (By Others) |
.156 Virgin | 2=2 Lamp | FT = Twin Tube T5 |
Acyrlic Lens | | | | | |
Voltage: | | | | | | |
| | | Options: |
120, 277 or | | | Add appropriate |
UNV=120-277 | | | suffix to catalog |
| | | | | no., ie: (A) |
| | Ballast Type: | | |
| | | | <20THD <10THD |
2 Lamp Elec. TT5 | | | SB* | IB** |
(25 or 40 Watt) | | | – | PR† |
2 Lamp Elec. TT5 | | |
(40 Watt) | | | BE* | | |
2 Lamp Elec. TT5 | | | | – |
(50 Watt) | | | – | BF* |
2 Lamp Elec. TT5 | | |
(55 Watt) | | | PB | | – |
LOL Dimming TT5 | | | |
*Instant Start Standard.
Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications (continuned)
Specifications
Performance: In an installation of 2 lamp 25W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .95. To reduce glare the average brightness at 65° shall not exceed 2648 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.9%.
Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group | Section 5/Folio MA12-10 |
Lightolier is a Philips group brand