OPERATION RANGES
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
MODE | OPERATIONAL TEMPERATURE | INDOOR | IF OUT OF CONDITIONS | ||
INDOOR | OUTDOOR | HUMIDITY | |||
|
| ||||
|
|
|
| Condensation may occur on | |
COOLING | 16˚C to 32˚C | 15˚C to 54˚C | 80% or less | the indoor unit with risk to have | |
either water blow off or drops on | |||||
|
|
|
| ||
|
|
|
| the floor. | |
|
|
|
|
| |
HEATING | 27˚C or less | - | Internal protection triggers and | ||
the air conditioner will stop. | |||||
|
|
|
| ||
|
|
|
|
| |
|
|
|
| Condensation may occur on | |
DRYING | 18˚C to 32˚C | 15˚C to 54˚C | - | the indoor unit with risk to have | |
either water blow off or drops on | |||||
|
|
|
| ||
|
|
|
| the floor. | |
|
|
|
|
|
The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
TECHNICAL SPECIFICATIONS
|
| MODEL |
|
| AQ18ESAUMG |
|
|
|
| AQ24ESAUMG |
| ||||||||
| STANDARD |
| ISO |
| SASO |
| ISO | SASO | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
CAPACITY |
|
| COOL |
| 18000BTU/h |
| 3850kcal/h |
| 24000BTU/h | 5000kcal/h | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| HEAT |
| 20000BTU/h |
| 5050kcal/h |
| 24000BTU/h | 6000kcal/h | ||||||||||
|
|
|
|
|
| ||||||||||||||
|
| SOURCE |
|
|
| 220V~,60Hz |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
CURRENT |
|
| COOL |
|
| 8.8A |
| 10.1A |
| 12.0A | 13.5A | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| HEAT |
|
| 8.2A |
| 8.2A |
| 12.0A | 12.0A | |||||||||
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
INPUT POWER |
| COOL |
| 1900W |
| 2250W |
| 2600W | 2900W | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| HEAT |
| 1900W |
| 1900W |
| 2600W | 2600W | |||||||||||
|
|
|
|
|
| ||||||||||||||
REFRIGERANT |
| KIND |
|
|
| R22 |
|
|
|
|
|
|
|
|
|
| |||
|
|
| QUANTITY |
|
| 1100g |
|
|
|
|
| 1370g |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
EER |
|
| COOL |
|
| 9.5 |
|
| 6.8 |
|
| 9.2 | 6.84 | ||||||
|
| HEAT |
|
| 10.5 |
|
| 10.5 | 9.2 | 9.2 |
| ||||||||
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INDOOR |
| DB(C/H) | 27°C |
| 20°C |
| 29°C |
| 21°C |
| 27°C |
| 20°C | 29°C |
| 21°C |
TEMPERATURE |
| WB(C/H) | 19°C |
| - |
| 19°C |
| - |
| 19°C |
| - | 19°C |
| - | |||
|
|
|
|
|
|
|
| ||||||||||||
OUTDOOR |
| DB(C/H) | 35°C |
| 7°C |
| 46°C |
| 7°C |
| 35°C |
| 7°C | 46°C |
| 7°C | |||
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
| WB(C/H) | 24°C |
| 6°C |
| 24°C |
| 6°C |
| 24°C |
| 6°C | 24°C |
| 6°C | |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
| INDOOR |
| NET |
|
| 13Kg |
|
|
|
|
| 13Kg |
| ||||
WEIGHT |
|
|
| CROSS |
|
| 16Kg |
|
|
|
|
| 16Kg |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| OUTDOOR |
| NET |
|
| 40Kg |
|
|
|
|
| 56Kg |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| CROSS |
|
| 44Kg |
|
|
|
|
| 58Kg |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ENGLISH