Sylvania Performance Guide, Specifications, Control Information, System Life / Warranty, WE T8

Page 4
Installation Notes

 

SPECIFICATION DATA

 

 

 

 

 

 

 

 

 

 

 

Catalog #

 

 

Date

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Project

 

 

Prepared by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Efficiency Electronic T8 Fluorescent Controllable Lighting Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Input

 

Rated

 

Ballast

Initial

Input

System

 

 

Item

 

 

Voltage

Current

Lamp

Lumens

No. of

Factor

System

Power

Efficacy

 

 

Number

 

Description

(VAC)

(AMPS)

Type

(lm)

Lamps

(BF)

Lumens

(Watts)

(lm/W)

BEF1

 

50705

 

QTP 1x32T8/UNV DIM-TC

120-277

0.27/0.12

FO32XP

3000

1

0.88

2640

30

88

2.93

S E

 

 

 

 

 

 

 

 

0.05

150

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50707

 

QTP 2x32T8/UNV DIM-TC

120-277

0.54/0.24

FO32XP

3000

2

0.88

5280

59/57

89/93

1.54

RS E N DIM

 

 

 

 

 

 

 

 

 

0.05

300

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50714

 

QTP 3x32T8/UNV DIM-TCL

120-277

0.73/0.30

FO32XP

3000

3

0.88

7920

87/84

91/94

1.05

 

 

WE T8

 

 

 

 

 

 

 

 

0.05

450

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50716

 

QTP 4x32T8/UNV DIM-TCL

120-277

0.96/0.40

FO32XP

3000

4

0.88

10560

114/110

92/96

0.80

P O

 

 

 

 

 

 

 

 

 

0.05

600

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Products are all 10-pack. 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (note: calculation based on lowest wattage value)

T8 POWERSENSE®

High Efficiency

Performance Guide

Data based on SYLVANIA OCTRON® lamps shown. QUICKTRONIC® POWERSENSE ballasts are also compatible with other manufacturers equivalent lamp types that meet ANSI specifications, including F17, F25, F32 and the U-Bend equivalent lamps.

Specifications

Data based on F32T8

Starting Method: Programmed Rapid Start

Circuit Type: Series

Lamp Frequency: >40 kHz

Lamp CCF: Less than 1.7

Starting Temp: 50°F/10°C minimum for OCTRON T8 lamps

Dimensions:

1 & 2 lamp enclosure

Overall: 9.5" L x 1.68" W x 1.0" H (241 x 43 x 25 mm)

Mounting: 8.90" (226 mm)

Weight: 1.1 lbs each (500 g)

3 & 4 lamp enclosure

Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm) Mounting:16.2" (411 mm)

Weight: 2.1 lbs each (950 g)

Wiring:

 

 

Leads Only

 

Width

 

 

43mm

 

 

(1.68")

Height

Mounting

 

Length

 

 

 

8.70 mm

 

 

Slot

Length

 

Width

 

 

 

 

Mounting

 

Height

411.3mm

 

(16.2")

Length

25.4mm

 

(1.0")

 

425mm

 

 

(16.7")

Input Voltage: 120-277V, ±10%

Input Frequency: 50/60 Hz

THD: <10% @ Full Output

Power Factor: >98% @ Full Output UL Listed Class P, Type 1 Outdoor CSA or C/UL Certified

70°C Max Case Temperature

FCC 47CFR Part 18 Non-Consumer Class A Sound Rating

ANSI C62.41 Cat. A Transient Protection Remote mounting (Max. wire length from ballast case to lampholder) up to 8 feet

Output Wiring: Lamp wiring for dimming ballasts can differ significantly from non-dimming ballasts and from other manufacturers dimming ballasts. Take care to connect lamp lead wires as

shown on the applicable ballast diagram. Lamp Seasoning: For optimal performance, fluorescent lamps may require seasoning for up to 12

hours prior to low temperature starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice — Lamp Seasoning for Fluorescent Dimming Systems

Control Information

QUICKTRONIC POWERSENSE ballasts are compatible with a wide range of low voltage (0-

1 lamp

Black

Red

White

Red

 

ELECTRONIC

 

Violet (+)

BALLAST

Blue

Grey (-)

 

Blue

LAMP 1

2 lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

 

 

Red

 

White

 

 

Red

 

 

 

 

 

 

 

ELECTRONIC

 

Blue

 

 

 

 

 

 

 

 

 

BALLAST

 

Blue

 

 

 

Violet (+)

 

Yel/Blk

 

 

 

 

 

 

 

 

 

 

Grey (-)

 

 

Yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

10VDC) and power line fluorescent controllers available from various manufacturers.

Low Voltage Control Specs: Ballast will source up to 0.5mA for 0-10VDC control purposes. May be wired as a Class 1 or Class 2 circuit- consult Local and National Electrical Codes. Power Line Control Specs: Specification- grade fluorescent controls are available for 120V or 277V operation of controllable analog electronic fluorescent ballasts.

3 lamp

Black

White

Violet (+)

Grey (-)

ELECTRONIC

BALLAST

Red

Red/White

Red/Black

Red/White

Yellow

Yel/Blk

Yellow

Blue

LAMP 1

LAMP 2

LAMP 3

4 lamp

Red/White

 

 

 

 

 

 

Red/Black

 

Black

 

Red/White

 

White

ELECTRONIC

Yellow

 

 

 

 

 

 

 

 

 

 

BALLAST

Yellow/Black

 

Violet (+)

Yellow

 

 

Grey (-)

 

Blue/White

 

 

 

 

 

 

 

 

 

 

 

 

Blue/Black

 

 

 

 

 

 

Blue/White

 

 

 

 

 

 

LAMP 1

LAMP 2

LAMP 3

LAMP 4

Controls must be suitably rated for both the type (e.g. Fluorescent Phasecontrol) and size (e.g. 600W) of the connected load.

System Life / Warranty

SYLVANIA

 

 

 

 

 

Blue

Input & Control

 

 

 

 

 

Wiring Options:

LOW-VOLTAGE CONTROL

POWERLINE CONTROL

 

LINE

 

BLACK

LINE

BLACK

 

NEUTRAL

 

WHITE

NEUTRAL

WHITE

 

 

 

 

 

Class 1 or

0-10VDC

VIOLET (+)

 

VIOLET (+)

 

Class 2

< 0.5mA

GREY (-)

INSULATE

 

GREY (-)

 

 

 

 

 

 

UNUSED LEADS

 

Item Number

 

 

 

50707 QTP 2 x 32T8 / UNV DIM-TC

 

System Type - DIMMING/Case Size

 

 

 

 

QUICKTRONIC PROFESSIONAL

 

 

 

 

 

 

 

Line Voltage (120-277V)

Number of Lamps (1, 2, 3, 4)

 

 

 

 

 

 

 

Primary Lamp Wattage

 

 

 

 

 

 

 

 

 

 

 

QUICKTRONIC products are covered by QUICK 60+®, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin.

OSRAM SYLVANIA

National Customer

Service and Sales Center

1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com

Specifications subject to change without notice.

©2010 OSRAM

SYLVANIA, the system solution, QUICK60+, POWERSENSE, See the World in a New Light and PROStart are registered trademarks of OSRAM SYLVANIA Inc.

ELOGIC is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. NEMA Premium is a registered trademark of National Electrical Manufacturers Association.

Image 4
Contents Key System Features Lamp / Ballast GuideSystem Information Application InformationQuicktronic Powersense Controls Information Controls GuideWire Powerline and 0-10Vdc Control with Powersense Ballasts Wire Powerline Control with Powersense BallastsSystem Life / Warranty Performance GuideSpecifications Control Information
Related manuals
Manual 4 pages 51.09 Kb

T8 specifications

Sylvania T8 fluorescent tubes are a popular choice in commercial and industrial lighting due to their energy efficiency, reliability, and versatility. These lights are designed to fit into standard T8 fixtures, making them an ideal replacement option for older lighting systems. The T8 designation refers to the tube’s diameter, which is 1 inch or 8/8 of an inch, providing a compact design that is both efficient and effective.

One of the main features of Sylvania T8 tubes is their energy efficiency. Compared to traditional incandescent bulbs and older fluorescent technology, T8 tubes consume significantly less power, leading to lower electricity costs and reduced environmental impact. Many Sylvania T8 models are designed to operate on an electronic ballast, further enhancing their efficiency by minimizing energy waste. As a result, businesses can benefit from reduced operational costs over time while contributing to sustainability efforts.

In terms of lumens output, Sylvania T8 tubes provide bright, uniform lighting, making them suitable for various applications, from offices and schools to warehouses and retail spaces. They are available in different color temperatures, typically ranging from warm white (around 3000K) to cool white (4000K) and daylight (5000K), allowing for flexibility in creating the desired ambiance in any setting.

Sylvania employs advanced technologies in their T8 tubes, including high-performance phosphor coatings that enhance light output and improve color rendering. With a Color Rendering Index (CRI) typically above 80, these tubes produce light that accurately depicts colors, making them ideal for environments where color accuracy is essential, such as art studios and design workplaces.

Another important characteristic of Sylvania T8 tubes is their long lifespan, often exceeding 20,000 hours. This longevity reduces the frequency of replacements, decreasing maintenance costs and labor associated with changing out bulbs. Moreover, these fluorescent lamps are designed with a consistent performance over time, ensuring that light levels remain stable throughout their lifespan.

In summary, Sylvania T8 fluorescent tubes offer a harmonious blend of efficiency, versatility, and longevity. Their high energy efficiency, excellent lumen output, diverse color temperature options, superior CRI, and durable construction make them a reliable lighting solution for a variety of commercial and industrial applications. Businesses looking to enhance their lighting while reducing energy costs would do well to consider Sylvania T8 tubes as a sustainable and effective choice.