Desa Air Conditioner owner manual Troubleshooting, Observed Problem Possible Cause Remedy

Page 7

TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

Fan does not turn when heater

1. No electrical power to heater

1.

Check voltage to electrical

is plugged in

 

 

outlet. If voltage is good,

 

 

 

check heater power cord for

 

2. Fan hitting inside of heater

 

breaks

 

2.

Adjust motor/fan mount to

 

shell

 

keep fan from hitting inside of

 

 

 

heater shell. Bend fan mount

 

 

 

if necessary

 

3. Fan blades bent

3.

Replace fan. See Fan, page 8

 

4. Defective motor

4.

Replace motor. See Motor,

 

 

 

page 8

 

 

 

 

Heater will not ignite

1. User did not follow installa-

1.

Repeat installation and opera-

 

tion or operation instructions

 

tion instructions. See Instal-

 

properly

 

lation, page 4 and Operation,

 

2. No spark at spark plug. To test

 

page 5

 

2.

A) Check spark plug wire.

 

for spark, follow step 8 under

 

Tighten or reattach loose spark

 

Spark Plug, page 9. If you see

 

plug wire. See Figure 8, page 9

 

spark at spark plug, have heater

 

for spark plug wire location

 

serviced by qualified service

 

B) Replace spark plug. See

 

person. If no spark seen:

 

Spark Plug, page 9

 

A) Loose or disconnected

 

C) Replace spark transformer.

 

spark plug wire

 

See Spark Transformer, page 9

 

B) Bad spark plug

 

 

 

C) Bad spark transformer

 

 

Heater shuts down while run- ning

1.Propane supply may be inad- equate

2.High surrounding air tem- perature causing thermal limit device to shut down heater.

3.Restricted air flow

4.Damaged fan

5.Excessive dust or debris in surrounding area

1.A) Refill tank

B)Provide additional and/or larger tanks. See Propane Supply, page 4

2.This can happen when running heater in temperatures above 85° F (29° C). Run heater in cooler temperatures

3.Check heater inlet and outlet. Remove any obstructions

4.Replace fan. See Fan, page 8

5.Clean heater. See Mainte- nance, page 6

WARNING:Useonlyinareas free of high dust content.

113893-01B

www.desatech.com

7

Image 7
Contents General Hazard Warning Table of ContentsSafety Information Unpacking Product IdentificationPropane Supply InstallationKg tanks needed to run this heater Provide propane supply system see Propane Supply, VentilationOperation To Start HeaterStorage MaintenanceHave heater inspected yearly by a qualified service agency Clean fan blades each season or as needed see Fan,Observed Problem Possible Cause Remedy TroubleshootingMotor Service ProceduresFAN Remove spark plug from rear head Remove orange spark plug wire from spark plugSpark Transformer Spark PlugWiring Diagram SpecificationsPropane/LP Gas Gas Supply Pressure to Regulator Parts not Under Warranty Replacement PartsTechnical Service Parts Under WarrantyModels 55-F, BLP55V, REM55PV, RLP55V and SPC-55 Illustrated Parts BreakdownParts List Models 85-FAC, BLP85V, REM85PV, RLP85V and SPC-85 Parts List Models 125-F, BLP125V, REM125PV, RLP125V and SPC-125 113909-01 Wiring Decal 113802-11 Model Data Decal 113933-02 Keep this Warranty Warranty and Repair Service