Environmental requirements

Flame retardants

Flame retardants are present in printed circuit boards, cables, wires, casings and housings. Their purpose is to prevent, or at least to delay the spread of fire. Up to 30% of the plastic in a computer casing can consist of flame retardant substances. Most flame retardants contain bromine or chloride, and those flame retardants are chemically related to another group of environmental toxins, PCBs. Both the flame retardants containing bromine or chloride and the PCBs are suspected of giving rise to severe health effects, including reproductive damage in fish-eating birds and mammals, due to the bio-accumulative* processes. Flame retardants have been found in human blood and researchers fear that disturbances in foetus development may occur.

The relevant TCO'99 demand requires that plastic components weighing more than 25 grams must not contain flame retardants with organically bound bromine or chlorine. Flame retardants are allowed in the printed circuit boards since no substitutes are available.

Cadmium**

Cadmium is present in rechargeable batteries and in the colour-generating layers of certain computer displays. Cadmium damages the nervous system and is toxic in high doses. The relevant TCO'99 requirement states that batteries, the colour-generating layers of display screens and the electrical or electronics components must not contain any cadmium.

Mercury**

Mercury is sometimes found in batteries, relays and switches. It damages the nervous system and is toxic in high doses. The relevant TCO'99 requirement states that batteries may not contain any mercury. It also demands that mercury is not present in any of the electrical or electronics components associated with the labelled unit. There is however one exception. Mercury is, for the time being, permitted in the back light system of flat panel monitors as today there is no commercially available alternative. TCO aims on removing this exception when a Mercury free alternative is available.

CFCs (freons)

The relevant TCO'99 requirement states that neither CFCs nor HCFCs may be used during the manufacture and assembly of the product. CFCs (freons) are sometimes used for washing printed circuit boards. CFCs break down ozone and thereby damage the ozone layer in the stratosphere, causing increased reception on earth of ultraviolet light with e.g. increased risks of skin cancer (malignant melanoma) as a consequence.

Lead**

Lead can be found in picture tubes, display screens, solders and capacitors. Lead damages the nervous system and in higher doses, causes lead poisoning. The relevant TCO'99 requirement permits the inclusion of lead since no replacement has yet been developed.

TCO'03-Ecological requirements for personal computers (TCO'03 applied model only)

Congratulations!

The display you have just purchased carries the TCO'03 Displays label. This means that your display is designed, manufactured and tested according to some of the strictest quality and environmental requirements in the world. This makes for a high performance product, designed with the user in focus that also minimizes the impact on our natural environment.

Some of the features of the TCO'03 Display requirements:

Ergonomics

Good visual ergonomics and image quality in order to improve the working environment for the user and to reduce sight and strain problems. Important parameters are luminance, contrast, resolution, reflectance, colour rendition and image stability.

Image 88
Contents Page Ström Använd inte en trasig eller lös kontaktInstallation Använd bara en ordentligt jordad kontakt och uttag honuttagTappa inte monitorn när Ni flyttar den Placera monitorn på en jämn och stadig ytaRengöring Sätt ner monitorn försiktigtLägg inte monitorn med skärmen nedåt Spruta inte rengöringsmedel direkt på monitornOther Täck inte över ventilerna på monitorns hölje Stick aldrig in någonting av metall i monitorspringornaPage Packa upp TillvalsmöjlighetGuide för snabb installation Garantikort Natural Color Kabel Signalkabel Elkabel DVI-kabel TillvalsmöjlighetFinns ej på alla platser FramsidanFavorit BaksidanDVI -port SyncMaster 710T / 910T / 711T / 912T / 701TOption SyncMaster 510N / 512N Kabel SignalkabelElkabel Baksidan SyncMaster 510T / 710T / 910T / 711T / 912T / 701T Page Montering av bildskärm Vridbar fot Montera en fotWindows XP/2000 Enkel fot Vridbar fotKlicka på Windows XP/2000 Driver Microsoft Windows XP OperativSystem Page Page Microsoft Windows NT OperativSystem Linux OperativSystemInstallation av Natural Color-programmet Natural ColorMjukvara för naturlig färg Natural Color Software Hur man raderar dataprogrammet Natural ColorAuto Ljus MagicBrightMagicBright Source Bild FärgBildinst LjusOSD Grov Fin Skärpa PositionInst InformationSpråk Position Transparens Visa tid Autokälla Återställ bild Återställ färgInformation Visar en bildkälla, visningsläge på OSD-skärmen Innehåll MagicBright Återställ bild Återställ färg Färg Position V-position Återställ bild Återställ färg Översikt Installera Page Installationsproblem SystemkravMaskinvara Definition av knapp Definition av BildDefinition av Färg LjusstyrkaDefinition av Geometri FärgtonDefinition av Alternativ BildinställningarDefinition av supportflik InställningFärgkalibrering Page Avinstallera Felsökning Ansluten med D-sub-kabeln Kan Ni se Kontr. signalkabel. på bildskärmen?Ansluten.Ansluten med DVI- kabeln Rekommenderat läge 1024 Kontrollera följande moment om det är bekymmer med monitorn Frågor och svarKontroll via det inbyggda testprogrammet VarningsmeddelandeNyttiga tips När man vill bedöma hur monitorn fungerarSymtom Bildskärmen visar konstiga färger eller bara svart och vitt Stäng av både datorn och monitorn Varningsmeddelande Page Allmänt AllmäntStrömspararen MiljöfaktorerFörinställningar på monitorn Tabell 1. Förinställningar på displayenModellnamn SyncMaster 910T / 912T Mindre ä 38W 31,500 VESA, 800 x 35,156 56,250 36,000 37,879 Modellnamn SyncMaster 710N / 712N EPA/ENERGY Förinställningar på monitorn Modellnamn SyncMaster 910N / 912N / 913N Strömspararen Förinställningar på monitorn Modellnamn SyncMaster 510T Yttermått bredd x djup x höjd / vikt 59,940 25,175 IBM, 640 x 31,469 70,086 Modellnamn SyncMaster 510N / 512N Strömspararen 75,000 VESA, 1024 x 60,023 75,029 78,750 +/+ Service Australia BrazilTultitlán, Estado de México, C.P Portugal United KingdomOrdlista För bättre bildFöretagsuppgifter och copyright User Information FCC Information User InstructionsIC Compliance Notice Why do we have environmentally-labelled monitors? MPR II Compliance European NoticeEurope Only PCT NoticeWhat does labelling involve? Environmental RequirementsLead CadmiumCFCs freons Why do we have environmentally labelled computers?TCO Development Environmental requirements Flame retardants ErgonomicsEnergy EmissionsEcology TCO03 Recycling Information TCO03 applied model onlyVideo In / RS 232 / Video Out Transport and Storage LimitationsStröm av, skärmsläckare eller strömsparläge Vad är bildkvarhållning?Förslag för specifika tillämpningar
Related manuals
Manual 92 pages 1.93 Kb Manual 91 pages 3.39 Kb Manual 90 pages 13.91 Kb Manual 93 pages 43.43 Kb Manual 94 pages 29.72 Kb Manual 91 pages 891 b Manual 97 pages 27.52 Kb Manual 93 pages 42 Kb Manual 182 pages 63.02 Kb Manual 185 pages 62.76 Kb Manual 182 pages 7.19 Kb Manual 183 pages 19.42 Kb Manual 179 pages 13.69 Kb Manual 180 pages 49.28 Kb Manual 178 pages 4.57 Kb Manual 186 pages 43.25 Kb Manual 182 pages 44.95 Kb Manual 189 pages 16.95 Kb Manual 98 pages 22.18 Kb Manual 98 pages 19 Kb Manual 91 pages 57.91 Kb Manual 91 pages 8.24 Kb Manual 91 pages 32.36 Kb Manual 177 pages 54.2 Kb Manual 180 pages 27.68 Kb Manual 179 pages 63.72 Kb Manual 188 pages 17.47 Kb Manual 91 pages 27.8 Kb Manual 92 pages 19.86 Kb Manual 91 pages 40.43 Kb Manual 96 pages 57.61 Kb Manual 88 pages 23.97 Kb Manual 96 pages 24.66 Kb Manual 93 pages 57.13 Kb Manual 88 pages 63.76 Kb Manual 88 pages 7.47 Kb Manual 89 pages 8.44 Kb Manual 89 pages 8.74 Kb Manual 90 pages 11.35 Kb Manual 87 pages 956 b Manual 89 pages 5.14 Kb Manual 89 pages 31.38 Kb Manual 81 pages 745 b Manual 96 pages 16.57 Kb