Chromalox PE417-3 specifications Installation, Wiring, Operation, Maintenance

Page 2

INSTALLATION

WARNING: Hazard of Electric Shock. Disconnect all power before installing heater.

1.Before installing, check your GCH/GCHIS circulation heater for any damage that may have occured during shipment.

2.Check to insure that the line voltage is the same as that stamped on the nameplate.

3.Vertical mounting (axis of chamber vertical as in Figures on pre- vious page) is preferred.

4.To avoid excess temperatures at electrical wiring, mount heater with terminal enclosure at bottom, and use lower nozzle as inlet to the circulating steam, air or gas.

5.The GCH/GCHIS series of circulation heaters is provided with mounting lugs to support the heater chamber. Refer to figures on previous page for location of these mounting lugs.

6.Mount heaters to permit unrestrained expansion of chamber due to

temperature. This can be accomplished by using a slotted mount- ing assembly on either of the lugs.

7.Provide adequate space at terminal end to permit withdrawal of the heater from chamber should servicing be required.

8.DANGER: Hazard of Fire. Provide a minimum of 6” spacing from chamber and related piping to nearest combustible material. Avoid operation of heater near combustible fluids or in com-

bustible vapor or gas laden atmosphere.

9. If two or more heaters are required to provide the needed heating capacity, arrange them for series gas or vapor flow.

10.DANGER: Possible Explosion. A pressure relief valve should be provided by customer at outlet of vessel. There should be no valving between vessel and relief valve.

11.In a forced circulation system, use pump on the inlet side.

WIRING

WARNING: Hazard of Electric Shock. Any installation involving electric heaters must be effectively ground- ed in accordance with the National Electrical Code to eliminate shock hazard.

1.Be sure line voltage matches heater voltage (on nameplate).

2.All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person as defined in the NEC.

3.Because of the high operating temperatures expected, 250˚C wire should be used.

4.Power controls must be used when heaters are rated 3 phase and when the heater amperage exceeds the rating of the thermostat.

5.Refer to Wiring Diagrams for the typical wiring used for connect- ing the GCH series heater.

6.Other circuit arrangements are often supplied depending upon cus- tomer specifications or amperage rating.

OPERATION

WARNING: Do not heat materials that are corrosive to the heating element sheath or chamber.

It is the responsibility of the user to know the chemical composi- tion of the corrosive solution and the character of the materials enter- ing the solution as well as the corrosive effect of the solution upon entering the heating elements and chamber. Chromalox cannot war- rant any electric circulation heater against failure by sheath corrosion if such failure is the result of operating beyond our control.

1.Terminal ends of heater must be protected from drippings, con-

densation, spray or direct spill-over of material whose presence at the terminals may damage heater electrical insulation. Liquid-tight terminal enclosures are available to protect heater. Consult your Local Chromalox Sales office.

2.If foreign material is carried by the gaseous flow, install suitable filters in the inlet pipe line to the heater.

3.Do not allow heater to operate when steam, air or gas flow is inter- rupted as dry operation of the heater can cause failure.

MAINTENANCE

1.WARNING: Hazard of Electric Shock. Disconnect all power before wiring or servicing heater.

2.Remove heating element assembly periodically to check heater sheath for corrosion or excessive oxidation. Correct operating con- ditions to minimize sheath deterioration.

3.Periodically check temperature control and pressure-temperature safety limit control operation to insure accurate and safe process operation.

4.Check all electrical connections periodically and retighten con- nections which may have loosened in service. Replace wire and wire terminals which show signs of oxidation which would inter- fere with establishment of reliable electrical connections.

5.Clean any filters in the inlet pipeline to avoid reduced flow, which can cause element overheating and premature failure.

Image 2
Contents Chromalox GeneralMaintenance InstallationWiring OperationTypical Wiring Diagrams SeriesLimited Warranty Renewal Parts Identification

PE417-3 specifications

The Chromalox PE417-3 is a cutting-edge industrial heating solution designed to meet the rigorous demands of both production and process heating applications. This robust electric heating element is engineered for efficiency and reliability, making it suitable for a variety of commercial uses.

One of the standout features of the PE417-3 is its powerful heating capacity. With a wattage of 4000 watts, this unit can deliver substantial heat output, ensuring quick and effective temperature control. Its versatility permits usage in diverse environments, including HVAC systems, food processing, and chemical manufacturing. Moreover, the PE417-3 can operate at voltages ranging from 208 to 480 volts, offering flexibility in installation.

The PE417-3 utilizes advanced material science for its construction, featuring high-grade stainless steel that guarantees durability and resistance to corrosion and oxidation. This enhances the longevity of the unit, minimizing the need for frequent replacements, thus reducing overall operational costs. The encapsulated design also protects the heating elements from environmental stressors, ensuring consistent performance over time.

In terms of technology, the Chromalox PE417-3 incorporates state-of-the-art temperature control systems. With its integrated thermocouple, users can achieve precise temperature measurement and control, ensuring optimal performance and safety. Additionally, the unit comes with advanced thermal insulation properties, significantly reducing heat loss and improving energy efficiency.

Another important characteristic of the PE417-3 is its ease of installation and maintenance. The unit is designed with user-friendly interfaces and clear wiring instructions, allowing for quick setup. Furthermore, it is compatible with various control systems, making it easy to integrate into existing processes or systems.

Furthermore, the PE417-3 complies with industry safety standards, providing peace of mind for operators. Its robust construction and safety features, such as over-temperature protection, ensure that the unit operates safely even in challenging environments.

Overall, the Chromalox PE417-3 represents a blend of reliability, efficiency, and innovation, making it a top choice for professionals in need of effective heating solutions. With its advanced features and engineering excellence, the PE417-3 stands out as a leader in the electric heating market.