Dayton 3VH37, 3VH34, 5VD57, 3.00E+134, 3.00E+132, 3E462 manual Heater Assembly Components side view

Page 22

 

3E132 thru 3E134, 3E460 thru 3E462,

Dayton Installation, Operation, Maintenance and Parts Manual

5VD57 thru 5VD66, 3VH34 thru 3VH37

 

 

Dayton® High Intensity Heaters

Heater Assembly Components

NOTE: Replacement burners are called “rayheads” with rod inserts (part no. DR-RH and DR-ROD).

Ceramic grids are not sold separately, order full assembly (part no. DR-RH).

EFigure 4.1 - Heater Assembly Components (side view)

N

G

Path of exhaust

L

 

I

 

S

 

H

 

Rods

Reflector Shield

Heat Shield

Rayhead Assembly with Ceramics

Side Frame

Brass Union

Manifold Pressure Tap

Manifold End

Frame Assembly

Gas Orifice

Electrode Assembly

Figure 4.2 - Spark Electrode Side View

Figure 4.3 - Heater Components (rear view)

 

Side Frame

 

 

 

Electrode Bracket

 

 

 

Proper installation results

 

 

Electrode

in 1/16” clearance from

 

Cross-over

face of ceramic

High Voltage

 

Bracket

 

Ceramic

 

Wire

 

 

Tile

 

 

Low Voltage

Gas Valve

 

Rods

 

Wire

 

 

Set gap to 1/8”

 

 

 

 

 

Junction

 

 

Circuit Board

Box

 

 

22

 

Image 22
Contents Description For Your Safety If you smell gasNot for residential use Installation Standards, Certifications and Government RegulationsApplications SafetySafety Symbols Commercial / IndustrialCombustible Items Include Clearance to CombustiblesHazards Include Moving Objects IncludeChart 1.1 Clearance to Combustibles in Inches see Figure Clearance to Combustibles DiagramPage 60,000 Chart 1.2 Heater Dimensions30,000 90,000Back Panel Safety Signs and LabelsBottom Panel Installation DesignPerimeter mounting Perimeter and center row mounting Infra-red heater Thermostat Air intake louver ExhausterSpot Heater Heights Heater Mounting Yton Hot Flue Discharge To connect the gas Chart 2.3 Manifold PressureGas Supply NaturalAppliance in the approved manner may Failure to install, operate or service thisLocal codes Electric Shock Hazard ElectricalAvoid Equipment Failure Wiring Diagrams Direct Spark Ignition VA Draw Amps Potted Circuit BoardShutdown Instructions Lighting InstructionsSequence of Operation Main Burner Gas SupplyChart 4.1 Troubleshooting Guide Heater Assembly Components Heater Assembly Components side viewChart 4.3 Miscellaneous Core Components Parts ListingChart 4.2 Direct Spark Control Components Contact factory for conversionLimited Warranty

3E460, 3E462, 3.00E+132, 3.00E+134, 5VD57 specifications

Dayton 3.00E+134, 5VD57, 3E462, 3E460, 3.00E+132 is a distinctive model within the Dayton series known for its advanced performance in various applications. This line of products is designed to meet the demands of both commercial and industrial sectors, showcasing a blend of efficiency, durability, and innovative technology.

One of the main features of the Dayton 3.00E+134 series is its powerful motor capabilities. The models utilize high-efficiency motors that ensure optimal energy consumption while providing robust operational performance. This not only helps to reduce utility costs but also plays a crucial role in minimizing the environmental footprint.

The technology behind Dayton products often incorporates advanced electronic controls that allow for precise adjustments and operations. This feature is particularly beneficial in environments where maintaining specific conditions is essential, such as HVAC systems and industrial processes. The electronic controls provide users with greater flexibility and range in performance settings, accommodating various operational requirements.

In terms of construction, the Dayton 3.00E+134 models are built with high-quality materials that ensure long-lasting durability. This is critical in settings where equipment is subjected to heavy usage or challenging environmental conditions. The robust design and protective coatings prevent corrosion and wear, ensuring that the equipment maintains its functionality over extended periods.

Another characteristic worth noting is the versatile range of applications for these models. They can be used in air movement, ventilation, heating, and cooling systems, making them highly valued in multiple sectors, such as manufacturing, healthcare, and commercial buildings. Their adaptability means they can seamlessly integrate into existing systems without requiring extensive modifications.

The ease of installation and maintenance is also a highlight of the Dayton 3.00E+134 series. The design facilitates quick assembly and access for servicing, saving valuable time and labor costs. Users appreciate the convenience offered, allowing them to focus on core business operations without prolonged downtime.

Furthermore, these models comply with industry standards and regulations, ensuring safety and reliability in operation. Overall, the Dayton 3.00E+134, 5VD57, 3E462, 3E460, 3.00E+132 series represents a pinnacle in engineering excellence, delivering exceptional performance across various applications while prioritizing energy efficiency and user-friendly functionality.