Desa H.S.I. Series owner manual Removing Burner Head, 70/90,000 BTU/Hr Models

Page 16

Nozzle

(70/90,000 BTU/Hr Models)

1.Remove upper shell (see page 10).

2.Remove fan (see page 19).

3.Remove fuel and air line hoses from burner head.

4.Remove spark plug wire from spark plug.

5.Remove spark plug from burner head using 13/16" open-end wrench.

6.Remove three screws using 5/16" nut-driver and remove burner head from combustion chamber.

7.Place burner head into vise and lightly tighten.

8.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 28).

9.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.

10.Inspect nozzle seal for damage.

11.Replace nozzle into burner head and tighten firmly

(80-110 inch-pounds/9.1-

12.4 n-m).

12.Attach burner head to combustion chamber.

13.Install spark plug in burner head.

14.Attach spark plug wire to spark plug.

15.Attach fuel and airline hoses to burner head.

16.Replace fan (see page 19).

17.Replace fan guard and upper shell.

16

Combustion

Chamber

Burner Head

Spark Plug

Wire

Screw

Spark

Plug

Air Line Hose

Fuel Line Hose

Figure 27 - Removing Burner Head, 70/90,000 BTU/Hr Models

Nozzle

Face

Nozzle

Seal

Nozzle

Burner

Head

Air line

Fuel line

Fitting

Fitting

 

Figure 28 - Removing Nozzle, 70/90,000 BTU/Hr Models

099605

Image 16
Contents Portable Forced AIR Heaters Contents Safety Information Carbon monoxide poisoning may lead to deathProduct Identification Unpacking Assembly Tools NeededOperation TheoryFuels Ventilation Operation To Start HeaterTo Stop Heater Operation Storage Preventative Maintenance ScheduleTo Restart Heater TROUBLE- Shooting How Often How ToUpper Shell Removal Service ProceduresFuel Filter Remove side cover screws using 5/16 nut-driver Spark Plug Spark Plug Removal, 30,000 BTU/Hr ModelSpark Plug Removal, 70/90/150,000 BTU/Hr Models Pump Pressure Adjustment Air Output, Air Intake, and Lint FiltersNozzle Removing Air and Fuel Line Hoses, 30,000 BTU/Hr ModelRemoving Burner Head, 70/90,000 BTU/Hr Models Removing Burner Head, 150,000 BTU/Hr Model Pump Rotor Rotor Location, 30/70,000 BTU/Hr ModelsSpecifications FanWiring Diagrams Wiring Diagram, 30,000 BTU/Hr EDI ModelWiring Diagram, 30,000 BTU/Hr EEI Model Parts Breakdown 30,000 BTU/Hr EDI/EEIParts List KEY Part QTY Number Description EDI EEIBurner Head Assembly 70,000 BTU/Hr EDI/EEIFHPF3-2C 90,000 BTU/Hr EDI/EEI Parts List Illustrated Parts Breakdown 150,000 BTU/Hr EDI/EEI150,000 BTU/Hr EDI/EEI WLM-4CWheels and Handles for 90,000 Accessories Warranty and Repair Service Certificate of General Equipment Limited 90 DAY Warranty