Desa FGHS30LPB AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Heater Location

Page 5

OWNER’S MANUAL

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

___________________ Btu/Hr

 

 

 

 

Gas water heater*

___________________ Btu/Hr

Example:

 

 

 

Gas furnace

___________________ Btu/Hr

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

___________________ Btu/Hr

Vent-free heater

+

30,000

Btu/Hr

Gas fireplace logs

___________________ Btu/Hr

Total

=

70,000

Btu/Hr

Other gas appliances* + ___________________ Btu/Hr

 

 

 

 

Total

= ___________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 70,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

107341

5

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual FGHS30LPBBlue Flame PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating HeaterInstalling Thermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Propane/LP supply Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Remedy Observed Problem Possible CauseFBD SpecificationsParts Centrals Thermostat Model FGHS30LPB ODS/Pilot AssemblyIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListTechnical Service Replacement PartsService Publications Accessories Service Hints107341 International Limited Warranty VENT-FREE Residential GAS Heaters

FGHS30LPB specifications

The Desa FGHS30LPB is a premium gas fireplace heater that combines style, efficiency, and modern technology to create a cozy and inviting atmosphere in any space. Designed with the contemporary homeowner in mind, this fireplace unit offers a unique blend of functionality and aesthetic appeal.

One of the standout features of the FGHS30LPB is its heating capacity. With a powerful output of up to 30,000 BTUs, this gas heater is capable of warming an area of approximately 1,200 square feet. This makes it an ideal choice for both large rooms and open-concept living spaces, ensuring that comfort is always within reach, even on the coldest days.

The FGHS30LPB showcases a sleek glass front that enhances its modern design while allowing for an unobstructed view of the beautiful flames. This glass is not only visually appealing but also contributes to the unit's efficient heating performance. The large viewing area allows for maximum heat transfer and real-time enjoyment of the dancing flames, making it the perfect focal point in any room.

Another key characteristic of the FGHS30LPB is its ceramic fiber logs, which mimic the look of real wood, providing an authentic fireplace experience without the hassle of traditional wood-burning stoves. Complemented by realistic glowing embers, this design results in a visually stunning display that brings warmth and charm to any interior space.

Technologically, the FGHS30LPB excels with its electronic ignition system. This feature allows for easy start-up with the simple push of a button, eliminating the need for matches or lighters. In addition, the unit is equipped with a built-in thermostat control that helps maintain the desired temperature, ensuring consistent comfort while optimizing fuel consumption.

Safety is also a priority for the FGHS30LPB, which includes features such as automatic shut-off and a protective screen. These aspects ensure that users can enjoy the warmth and ambiance of the fireplace without concern.

Overall, the Desa FGHS30LPB is an exceptional choice for anyone seeking an efficient and stylish gas fireplace heater. With its impressive heating capabilities, realistic flame appearance, and modern technology, it is designed to enhance both comfort and aesthetics in your home. Whether for daily use or special occasions, this fireplace unit offers a blend of performance and elegance, making it an outstanding addition to any household.