OWNER’S MANUAL
TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
Heater produces unwanted odors | 1. | Heater burning vapors from paint, hair |
|
| spray, glues, etc., (see IMPORTANT |
|
| statement above) |
| 2. | Low fuel supply |
| 3. | Gas leak. See Warning statement at |
|
| top of page |
1.Ventilate room. Stop using
2.Refill supply tank
3.Locate and correct all leaks (see Check- ing Gas Connections, page 10)
Heater shuts off in use (ODS operates) | 1. | Not enough fresh air is available | 1. | Refer to Air for Combustion and Venti- |
|
|
|
| lation requirements (page 4) |
| 2. | Low line pressure | 2. | Contact local propane/LP gas company |
| 3. | ODS/pilot is partially clogged | 3. | Clean ODS/pilot (see Cleaning and |
|
|
|
| Maintenance, page 12) |
|
|
|
|
|
Gas odor even when control knob is in OFF | 1. | Gas leak. See Warning statement at | 1. | Locate and correct all leaks (see Check- |
position |
| top of page |
| ing Gas Connections, page 10) |
| 2. | Control valve defective | 2. | Replace control valve |
Gas odor during combustion | 1. | Foreign matter between control valve |
|
| and burner |
| 2. | Gas leak. See Warning statement at |
|
| top of page |
1.Take apart gas tubing and remove for- eign matter
2.Locate and correct all leaks (see Check- ing Gas Connections, page 10)
Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air | 1. Refer to Air for Combustion and Venti- |
| lation requirements (page 4) |
www.desatech.com