Desa RN30B, CGN18B installation manual Check GAS Type, Installation Items, Locating Heater

Page 9

INSTALLING TO WALL

NOTICE

A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing the heater, make sure you have the items listed below.

• piping (check local codes)

• test gauge connection * (see

sealant (resistant to propane gas)

 

Figure 12, page 15)

• manual shutoff valve *

• sediment trap

ground joint union

tee joint

 

 

pipe wrench

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 27.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING

Maintain the minimum clearances shown in Figure 4 (page 10). If you can, provide greater clearances from floor, ceiling, and joining wall.

You can locate model CGN18B on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 27.

WARNING

Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION

WARNING ICON

G 001

This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, in- stalling heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Combustion and Ventilation, pages 5 through 8.

Continued

9

100096

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRInstallation Items Check GAS TypeLocating Heater Floor CeilingRight 16 3/ 4 RN30BMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingGRH/OV 007G Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litBurner Flame Pattern Correct Flame Pattern AT High PositionIncorrect Flame Pattern AT High Position Observed Possible Problem Cause Remedy Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetTROUBLE- Shooting Maintenance,From Top Ing statement atTechnical Service Service HintsRN30B CGN18B Replacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Accessories Manual ShutoffFloor Mounting Stand GA4000B ODS/Pilot KEY Part Number Description QTY RN30B Parts List12-2 12-1 CGN18B Parts List Limited Warranty VENT-FREE Heaters Warranty Information

RN30B, CGN18B specifications

Desa CGN18B and RN30B are innovative indoor heating solutions that cater to both residential and commercial needs, offering efficient heating capabilities with advanced features. Both models have carved a niche for themselves in the market, owing to their reliable performance, user-friendly interfaces, and modern design.

The Desa CGN18B is a gas-fired vent-free heater that has garnered attention due to its sleek design and compact size, making it an excellent choice for smaller spaces. With a heating capacity of 18,000 BTUs, it can effectively warm up areas up to 700 square feet, which is ideal for bedrooms, living rooms, or even office settings. One of the standout features of the CGN18B is its thermostat, which allows users to maintain their desired room temperature, enhancing comfort while optimizing energy consumption. The model operates without the need for external venting, which simplifies installation and reduces overall costs. Additionally, the CGN18B boasts safety features such as an oxygen depletion sensor, which automatically shuts the heater off if oxygen levels fall below a safe threshold, ensuring peace of mind for users.

On the other hand, the Desa RN30B is a dual-fuel heater that offers versatility by accommodating both liquid propane and natural gas. This flexibility makes it a preferred option for homeowners who may want to switch fuel sources based on availability or preference. With a robust heating capacity of 30,000 BTUs, the RN30B can comfortably heat larger spaces, up to 1,000 square feet. This model is particularly designed for heavy-duty use, making it suitable for workshops or larger living areas. The RN30B comes equipped with an electronic ignition system that simplifies startup, eliminating the need for matches or lighters. Moreover, its sleek design allows it to blend seamlessly with various interior styles, while the easy-to-use control panel enhances user experience.

Both models showcase advanced heating technologies, such as radiant heat distribution, which ensures warmth is spread evenly throughout the room. Furthermore, the efficient combustion technology employed in both units maximizes fuel utilization, thereby minimizing environmental impact while lowering energy expenses.

In conclusion, Desa CGN18B and RN30B are exemplary choices in the realm of indoor heaters. Their unique features, enhanced safety measures, and efficiency render them highly suitable options for those seeking dependable and effective heating solutions. Whether for a cozy home environment or a larger workspace, these models are designed to meet diverse heating needs effectively.