OWNER’S MANUAL
SPECIFICATIONS
| CGP6 | CGP10A |
Btu (Variable) | 4,400/6,000 | 5,000/10,000 |
Type Gas | Propane/LP Only | Propane/LP Only |
Ignition | Piezo | Piezo |
Pressure Regulator Setting | 8" W.C. | 8" W.C. |
Inlet Gas Pressure (inches of water) |
|
|
Maximum | 14" | 14" |
Minimum | 11" | 11" |
Dimensions, Inches (H x W x D) |
|
|
Heater | 20 1/2 x 13 1/2 x 5 | 20 1/2 x 13 1/2 x 5 |
Carton | 25 x 16 11/16 x 7 1/2 | 25 x 16 11/16 x 7 1/2 |
Weight (pounds) |
|
|
Heater | 13.5 | 13.5 |
Shipping | 19 | 19 |
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealer from whom you purchased this product. If they cannot sup- ply original replacement part(s), call DESA International’s Technical Service Depart- ment at
When contacting your dealer or DESA In- ternational, have ready:
• | your name |
• | your address |
• | model number of your heater |
• | how heater was malfunctioning |
TECHNICAL
SERVICE
You may have further questions about in- stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni- cal Service Department at
SERVICE PUBLICATIONS
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
• | type of gas used (propane/LP or natu- |
| ral gas) |
• | purchase date |
Usually, we will ask you to return the defec- tive part to the factory.
Parts Not Under Warranty
SERVICE HINTS
When gas pressure is too low
•pilot will not stay lit
•burner will have delayed ignition
•heater will not produce specified heat
•propane/LP gas supply may be low
When gas quality is bad
•pilot will not stay lit
•burner will produce flames and soot
•heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.
ACCESSORY
Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, either contact your nearest Parts Central (see page 18) or call DESA International’s Parts Department at
MANUAL SHUTOFF
VALVE - GA5010
Manual shutoff valve with 1/8" NPT tap.
Contact authorized dealers of this product. If they cannot supply original replacement part(s), either contact your nearest Parts Central (see page 18) or call DESA International’s Parts Department at
When calling DESA International, have ready:
•model number of your heater
•the replacement part number
101871 | 15 |