Desa CGB35N, CGB50N installation manual Safety Information

Page 4

SAFETY INFORMATION

Continued

4

WARNINGS Continued

6.Provide the following minimum heater clearances from combustibles (as viewed from the front of heater):

Front: 48 inches

Back: 6 inches

Top: 53 inches

Right Side: 12 inches

Left Side: 6 inches

7.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

8.Never place clothing or any flammable objects on the heater or venting system.

9.Heater and venting system surfaces are very hot during operation. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Carefully supervise young children when they are in the same room as heater. Heater will remain hot for a time after shutdown. Let surface cool before touching.

10.Do not use heater as a cooking device.

11.Do not alter heater or its controls. Any change may create a safety hazard.

12.Turn off heater and unplug (if equipped with blower) and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

13.Replace any safety screen or guard removed for servicing before running heater.

14.Do not use heater if any part has been under water. Immediately call a qualified service person to inspect the heater and to replace any part of the control system and any gas control which has been under water.

100351

Image 4
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product Identification Installation Items Local Codes Unpacking Product FeaturesCheck GAS Type Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply Connecting Heater to Utility Gas LineGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Glass Panel Removing Lower Front Access PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Operating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Manual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingObserved Possible Remedy Problem Cause Gas leak. See Warning Statement at topService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Orifice Location 35,000 BTU/Hr Burner ShownTechnical Service Service Hints35,000 BTU/Hr ModelParts Under Warranty Ordering Replacement Parts CentralsParts Not Under Warranty Accessories Valve GA5010Illustrated Parts List QTY Cabinet Assembly 100351 Warranty Information International

CGB50N, CGB35N specifications

Desa CGB35N and CGB50N are high-efficiency gas burners designed for various residential and commercial heating applications. These models stand out for their advanced technology, reliability, and user-friendly features.

The CGB35N is a compact, wall-mounted gas burner designed for efficient space heating solutions. With a thermal output of up to 35 kW, it is ideal for smaller homes or commercial spaces that require effective heating without excessive energy consumption. The burner is equipped with a modulating output, which allows it to adjust its power based on heating demands, leading to significant energy savings and consistent comfort levels.

In contrast, the CGB50N provides a higher thermal output of 50 kW, making it suitable for larger spaces or applications requiring additional heating capacity. Both models are designed to operate quietly and efficiently, ensuring a comfortable environment while maintaining low operational noise levels.

One of the key features of both the CGB35N and CGB50N is their high-efficiency condensing technology. This technology captures and utilizes the heat from the exhaust gases that would typically be wasted in traditional heating systems, resulting in improved energy efficiency and reduced carbon emissions. The appliances boast low NOx emissions, adhering to stringent environmental regulations, making them an eco-friendly choice for conscientious consumers.

Installation and maintenance of both units are straightforward, thanks to their compact design and accessible components. They come equipped with an intelligent control system that monitors performance in real-time, ensuring optimal operation and enabling users to easily adjust settings via a digital interface. This user-centric design enhances the overall experience and allows for quick troubleshooting when necessary.

Additionally, both models support integration with smart home systems, allowing users to control heating remotely and set schedules tailored to their lifestyle. This feature not only improves convenience but also further optimizes energy usage.

In summary, the Desa CGB35N and CGB50N gas burners combine high efficiency, advanced technology, and user-friendly features to provide reliable heating solutions for diverse applications. Their outstanding performance, environmental consciousness, and smart capabilities make them ideal choices for modern heating needs.