Spark Plug

1.Remove upper shell (see page 10).

2.Remove fan (see page 10).

3.Remove spark plug wire from spark plug.

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Clean and regap spark plug elec- trodes to .075" gap.

6.Install spark plug in burner head.

7.Attach spark plug wire to spark plug.

8.Replace fan (see page 10).

9.Replace fan guard and upper shell.

Nozzle

1.Remove upper shell (see page 10).

2.Remove fan (see page 10).

3.Remove fuel and air line hoses from burner head.

4.Remove spark plug wire from spark plug.

5.Remove spark plug from burner head using 13/16" open-end wrench.

6.Remove three screws using

5/16" nut-driver and remove burner head from combustion chamber.

7.Place burner head into vise and lightly tighten.

8.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 14).

9.Blow compressed air through face of nozzle. This will free any dirt in nozzle area.

10.Inspect nozzle seal for damage.

11.Replace nozzle into burner head and tighten firmly (9.1-12.4 n-m /80-110 inch-pounds).

12.Attach burner head to combustion chamber.

13.Install spark plug in burner head.

14.Attach spark plug wire to spark plug.

15.Attach fuel and airline hoses to burner head.

16.Replace fan (see page 10).

17.Replace fan guard and upper shell.

12

Burner Head

Spark Plug Wire

Spark

Plug

Figure 12 - Spark Plug Removal

Bend Here to Adjust Gap

Gap

 

Figure 13 - Spark Plug Gap

Combustion

 

Chamber

Burner Head

Spark Plug Wire

Screw

Spark

Plug

Air Line Hose

Fuel Line Hose

 

 

Figure 14 - Removing Burner Head

Nozzle

Nozzle Seal

 

Face

 

Nozzle

 

Burner

HeadFuel Line

Fitting

Air Line

Fitting

Figure 15- Removing Nozzle

102424

Image 12
Contents Portable Forced AIR Heaters Contents Safety Information Product Identification Unpacking Assembly Tools NeededTheory FuelsVentilation Operation To Start HeaterPreventative Maintenance Schedule Operation StoringTo Stop Heater To Restart HeaterTROUBLE- Shooting Possible CauseService Procedures Upper Shell RemovalFan Air Output, Air Intake, and Lint FiltersPump Pressure Adjustment Fuel FilterSpark Plug NozzleInstall insert and rotor Pump RotorSpecial tool to check pump pressure Wheels and Handle Parts List Parts Breakdown 100,000 Btu/Hr Model BY100ECAParts List KEY Part Number Description QTY150,000 Btu/Hr Model BY150ECA 150,000 Btu/Hr BY150ECA EC Conformity Declaration EC Conformity Declaration102424 102424 102424 Warranty and Repair Service Duration of this Express Warranty