INSTALLATION
6
!WARNING
Review and understand the warnings in the Safety Informa- tion Section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
!WARNING
Test all gas piping and connections for leaks after installa- tion or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1.Provide propane supply system (see Propane Supply, page 5).
2.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using
wrench. IMPORTANT: Position regulator so that hose leaving the regulator is in a horizontal position (see Figure 3). This places the regulator vent in the proper position to protect it from the weather.
Propane
SupplyRegulator
Valve
Propane | Hose |
| |
Tank | POL Fitting |
| |
| Figure 3 - Regulator Position |
3.Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT: Use extra hose or piping if needed. Install extra hose or piping between hose/regulator assembly and propane tank. You must use the regula- tor supplied with heater.
Inlet Connector | Hose |
Figure 4 - Hose and Inlet Connector
100585