Desa RM100LP owner manual Storage, Maintenance, To Start Heater, To Stop Heater

Page 5

OWNER’S MANUAL

OPERATION

WARNING: Follow the mini- mum fresh, outside air ventila- tion requirements. If proper fresh, outside air ventilation is not pro- vided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ventilation be- fore running heater.

WARNING: Review and under- stand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.Make sure the control knob is in the OFF position.

4.Plug power cord of heater into a three-prong, grounded extension cord. Extension cord must be at least six feet long, UL/CSA listed, and of a proper size.

Extension Cord Size Requirement

Up to 100 feet long, use 16 AWG rated cord.

101 to 200 feet long, use 14 AWG rated cord.

5.Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater.

6.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow you may hear a click inside the regulator assembly. If this happens, reset the excess-flow check valve by closing propane supply valve and open again slowly.

7.Press and hold in control knob. Turn counterclockwise to the LOW position. Heater should ignite within a few seconds.

Note: If heater fails to ignite, hose may have air in it. If so, keep control knob pressed and wait 20 seconds. Release automatic control valve button and wait 20 seconds for unburned fuel to exit heater. Repeat step 7.

8.After heater ignites, wait 30 seconds. This activates the automatic control system. Release the control knob.

9.When burner remains lit, set heater at the desired heat level by turning the control valve counterclockwise. If burner goes out, turn off gas. Turn control knob fully clockwise to the lowest position. Check fuel supply. If adequate fuel is available, restart heater beginning at step 1.

TO STOP HEATER

1.Tightly close propane supply valve on propane tank(s).

2.Wait a few seconds. Heater will burn gas left in supply hoses.

3.Turn control knob to the OFF position.

4.Unplug heater.

STORAGE

CAUTION: Disconnect heater from propane supply tank(s).

1.Store propane tank(s) in safe manner. See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Propane Installation Code CAN/CGA B149.2. Follow all local codes. Always store propane tanks outdoors.

2.Place plastic cover caps over brass fittings on inlet connector and hose/ regulator assembly.

3.Store in dry, clean, and safe place. Do not store hose/regulator assembly inside heater combustion chamber.

4.When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.

MAINTENANCE

WARNINGS

Never service heater while it is plugged in, connected to pro- pane supply, operating, or hot. Severe burns and electrical shock can occur.

Keep heater clear and free from combustible materials, gaso- line, and other flammable va- pors and liquids.

Do not block the flow of com- bustion or ventilation air.

1.Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use household cleaners on difficult spots.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace with hose specified by manufacturer.

4.Have heater inspected yearly by a qualified service agency.

5.Keep inside of heater free from combustible and foreign objects. Remove motor and other internal parts if needed to clean inside of heater (see Service Procedures, page 7).

6.Clean fan blades each season or as needed (see Fan, page 7).

105342

5

Image 5
Contents Propane Construction Heaters Propane Construction Heater Safety InformationTheory Operation Product IdentificationUnpacking Ventilation InstallationPropane Supply Storage MaintenanceTo Start Heater To Stop HeaterObserved Fault Possible Cause Remedy TroubleshootingFAN Service ProceduresMotor Technical Service AccessoriesSpark Transformer IgnitorWiring Diagram SpecificationsReplacement Parts Illustrated Parts Breakdown KEY Part Number Description QTY Parts ListKeep this Warranty Limited Warranty Warranty and Repair ServiceWarranty Service Repair Service

RM100LP specifications

Desa RM100LP is an innovative residential development designed to cater to modern living needs while maintaining affordability. Located strategically within a growing urban area, the project is gaining attention for its unique blend of contemporary design and practical functionality.

One of the main features of Desa RM100LP is its commitment to offering quality living spaces at an accessible price point. The development includes a variety of unit sizes and layouts, ranging from cozy apartments to spacious family homes, ensuring that there is something for everyone. The homes are designed with an emphasis on open spaces and natural light, creating a warm and inviting atmosphere for residents.

Technologically, Desa RM100LP incorporates smart home features that enhance the living experience. Residents can enjoy the convenience of smart lighting, energy-efficient appliances, and advanced security systems all integrated into their homes. These technologies not only increase comfort but also promote sustainability and reduce energy costs, aligning with modern eco-friendly standards.

Sustainability is a key characteristic of the Desa RM100LP project. The development boasts green spaces, community gardens, and recreational areas that encourage outdoor activities and social interaction among residents. The use of sustainable building materials further emphasizes the commitment to environmental responsibility, ensuring that the development has a minimal ecological footprint.

Accessibility is another vital aspect of Desa RM100LP. The project's location is strategically chosen to be close to essential amenities such as schools, shopping centers, and healthcare facilities. The development is also well-connected to public transportation, making it easy for residents to commute to work or explore the vibrant surroundings.

In terms of community engagement, Desa RM100LP promotes a sense of belonging among its residents. Regular community events and activities are organized to foster connections and enhance the quality of life for all inhabitants.

Overall, Desa RM100LP embodies modern living principles by combining affordability, sustainability, technology, and community spirit. Its thoughtful design and strategic location make it an attractive option for individuals and families looking for a comfortable and dynamic living environment. Whether you are a first-time homebuyer or seeking a new community, Desa RM100LP is poised to meet your needs and exceed your expectations.