50,000 BTU/HR

PROPANE CONSTRUCTION HEATER

SPECIFICATIONS

Output Rating (BTU/Hr)

 

High

49,500

Low

30,000

Fuel

Propane Vapor Only

Fuel Consumption

 

Gallons/Hour

2.19 / 1.09

Pounds/Hour

9.28 / 4.64

Supply Pressure To Regulator

 

Minimum (for input adjustment)

10 psi

Maximum

200 psi

Regulator Outlet Pressure

 

High

18" WC

Manifold Pressure

 

High

13.7" WC

Low

17" WC

Hot Air Output (CFM Approx)

275

Motor

3300 RPM

Electric Input

120 volt/60 hertz

Amperage

2

Ignition

Manual, Piezo

Ignitor Gap

0.17"

Temperature Range for Operation*

-20°F to 85°F *

Heater Weight (Pounds)

14.5

Shipping Weight

16

Size - L x W x H (Inches)

18.5 x 7.7 x 12.8

*When running heater in temperatures above 85° F, high internal temperatures may cause thermal limit device to shut down heater.

ACCESSORIES

Purchase accessories and parts from your

DESA International

nearest dealer or service center. If they can

P.O. Box 90004

not supply an accessory or part, either con-

Bowling Green, KY

tact your nearest Parts Central (listed in the

42102-9004

separate Authorized Service Center book-

1-800-972-7879

let) or contact DESA International for infor-

Parts Department

mation.

 

Part Number

Description

 

 

LPA3105

Hose/Regulator Assembly

 

U.L. listed.

LPA4020

Fuel Gas Connector

REPLACEMENT PARTS

WARNING: Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fa- tal injuries. This will also protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest autho- rized service center or call DESA International’s Technical Service Depart- ment at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

model number of your heater

how heater was malfunctioning

purchase date

In most cases, we will ask you to return the defective part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

Connects regulator to all standard propane tanks. U.L. and A.G.A. listed.

12

105338

Image 12
Contents Propane Construction Heater Safety Information Propane Construction HeaterProduct Identification UnpackingPropane Supply Assembly Theory OperationInstallation VentilationStorage To Start HeaterTo Stop Heater To Restart HeaterMaintenance TroubleshootingService Procedures Electrical SystemMotor Ignitor FanIllustrated Parts Breakdown RM50PVAParts List KEY Part Description QTYSpecifications AccessoriesReplacement Parts Parts Under Warranty105338 Warranty and Repair Service