Desa VN1000B Fresh AIR for Combustion and Ventilation, Producing Adequate Ventilation

Page 5

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING

WARNING ICON

G 001

 

 

This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PRODUCING ADEQUATE VENTILATION

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space.

The information on pages 5 through 8 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continu- ous water vapor retarder with a rating of one perm or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, continue reading.

Unconfined Space

An unconfined space has a minimum air volume of 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.

Confined Space

A confined space has an air volume of less than 50 cubic feet for each 1000

 

BTU/Hr input rating of all appliances in the space (cubic feet equals length x

 

width x height of space). Include adjoining rooms only if there are doorless

 

passageways or ventilation grills between the rooms.

Continued

5

 

099400

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installation ItemsCheck GAS Type Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingControl knob and turn counterclockwise C-clockwise Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice TROUBLE- Shooting Observed Possible Remedy Problem CauseCleaning and Mainte Top Ing statement atService Hints Technical ServiceParts Under Warranty Replacement Parts Service Publications AccessoryParts Not Under Warranty Valve GA5010Heater Exploded View KEY Part Number Description QTY Parts ListKeep this Warranty Warranty Information

VN1000B specifications

Desa VN1000B is a highly versatile and advanced generator known for its reliability and efficiency in providing power for various applications. This generator is particularly popular among homeowners, outdoor enthusiasts, and essential businesses that require uninterrupted power supply. The VN1000B has been designed with a focus on user-friendly features, strong performance, and durability, making it an ideal choice for both occasional and emergency use.

One of the main features of the Desa VN1000B is its compact size and portability. Weighing only around 50 pounds, it is easy to transport, making it suitable for camping trips, outdoor events, and home use. The generator is equipped with a foldable handle and sturdy wheels, facilitating mobility. Its compact design does not compromise on power output, as the VN1000B can produce a maximum wattage of 1000 watts and a continuous wattage of 800 watts, ensuring it can run a variety of appliances and tools.

Incorporating advanced technologies, the VN1000B is powered by a reliable four-stroke engine that operates quietly and efficiently. This generator features low noise technology, which minimizes sound output, making it an excellent choice for residential areas and quiet environments. With an innovative exhaust system, it ensures lower emissions compared to traditional generators, making it environmentally friendly and compliant with regulations.

The Desa VN1000B is also equipped with essential safety features. Its built-in circuit protection prevents overload, ensuring safe operation when running multiple devices. Furthermore, the generator includes a fuel shut-off system that allows for easy maintenance and longevity of the engine, reducing wear and tear.

Users will appreciate the versatile power outlets provided by the VN1000B, including multiple 120V AC outlets and a DC outlet for charging batteries or running small appliances. The generator's fuel tank has a capacity of 1.1 gallons, offering a run time of up to 6 hours on a quarter load. This efficiency makes it a practical solution for both recreational and emergency power needs.

In conclusion, the Desa VN1000B generator stands out due to its compactness, efficiency, low noise operation, and user-friendly features. With its strong power output and safety mechanisms, it is perfect for various applications, making it a top choice in the portable generator market. Whether you need supplemental power at home or reliable backup during outages, the VN1000B delivers on all fronts.