Desa GAS LOG HEATER installation manual Connecting to GAS Supply, Gas Connection

Page 12

VANGUARD FLAME-MAX®

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

A.G.A. Design-Certified

Manual Shutoff Valve With

1/8" NPT Tap*

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 30.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

CAUTION: Use only new,

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Tee Joint

 

Pipe

3" Minimum

Nipple

 

Cap

 

Sediment

Trap

Approved Flexible Gas Hose (if allowed by local codes)

Gas

Regulator

black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Figure 13 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 30.

**Minimum inlet pressure for purpose of input adjustment.

12

104342

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASFLAME-MAX Vintage Oak FLAME-MAX BirchSafety Information Vanguard FLAME-MAX Unvented Natural GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace Clearance To Combustible MaterialsIf Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs For Vintage Oak Log ModelFor Golden Oak or Birch Models Operating Heater Lighting InstructionsManual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Cleaning and Maintenance Replacement PartsIllustrated Parts Breakdown FLAME-MAX Vintage OAK LOG Models VYS18N and VYS24NODS Pilot Parts List VYS18N VYS24NODS Pilot VYD18N, VYBD18N VYD24N, VYBD24N VYD30N, VYBD30N VYD36N Thermostatically Controlled Models VYD18NT VYD24NT VYD30NT VYD18NT VYD24NT VYD30NT VYD18NT VYD24NT VYD30NTAccessories Service HintsTechnical Service 104342 Warranty Information International

GAS LOG HEATER specifications

Desa GAS LOG HEATER is a popular heating solution that brings the warmth and ambiance of a traditional fireplace to modern living spaces. Renowned for its efficiency and aesthetic appeal, this gas log heater is designed to replicate the flickering flames and the cozy feel of a wood-burning fire without the associated hassles.

One of the primary features of the Desa GAS LOG HEATER is its realistic flame effect, which is created using advanced gas log technology. The heater utilizes artificial logs that are crafted to resemble real wood, enhancing the visual appeal and creating a nostalgic atmosphere. The flames are adjustable, allowing users to customize the intensity based on their preferences and heating needs.

Efficiency is a hallmark of the Desa GAS LOG HEATER. Equipped with a high-efficiency heating system, it effectively converts gas to heat, ensuring that energy consumption is kept to a minimum. This results in lower utility bills and a reduced carbon footprint, making it an environmentally friendly option for homeowners. The heater's BTU output can vary, allowing it to accommodate different room sizes and layouts.

The Desa GAS LOG HEATER also features easy ignition systems, which simplify the startup process. Many models come with an automatic ignition option or a push-button start, eliminating the need for matches or lighter. Furthermore, they often include adjustable heat settings, enabling users to control the temperature easily.

Safety is a critical concern with gas heaters, and Desa addresses this with built-in safety features. These may include safety shut-off valves, thermocouple sensors, and automatic shut-off systems that activate in case of malfunction or if the heater tips over. This provides peace of mind for families with children or pets.

Installation of the Desa GAS LOG HEATER is generally straightforward, especially compared to traditional wood-burning fireplaces. Many units can be vented directly through an exterior wall, reducing the need for extensive chimney systems. This versatility allows homeowners to place the heater in various locations, enhancing the overall design of their spaces.

In summary, the Desa GAS LOG HEATER combines style, efficiency, and safety to deliver a reliable heating solution. Its realistic flames and efficient operation make it an attractive choice for anyone seeking to enjoy the charm of a fireplace without the complexities of wood burning. As energy efficiency and environmental consciousness continue to rise, the Desa GAS LOG HEATER stands out as a smart option for modern homes.