Desa VP11, VP5A Connecting to GAS Supply, External Regulator With Vent Pointing Down

Page 9

CONNECTING TO GAS SUPPLY

NOTICE

A qualified service person must connect heater to gas supply. Follow all local codes.

!CAUTION

Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply.

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 10. Pointing the vent down protects it from freezing rain or sleet.

Propane

Supply Tank

External

Regulator

Vent Pointing

Down

Figure 10 - External Regulator With Vent Pointing Down

!CAUTION

Use only new, black iron or steel pipe. Copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 11, page 10).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

!CAUTION

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Install sediment trap in supply line as shown in Figure 11. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Continued

9

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemInstallation Items Check GAS TypeLocating Heater Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Pilot Burner Patterns To Select Heating LevelInspecting Burner Manual Lighting ProcedureTo Turn OFF GAS to Appliance Pilot Flame PatternBurner Flame Pattern Cleaning and MaintenanceODS/PILOT and Burner Orifice CabinetObserved Possible Problem Cause Remedy Trouble ShootingCleaning Observed Possible Problem Cause Remedy Ing statement at Technical ServiceTop VP11Parts Under Warranty Parts Not Under WarrantyValve GA5010 Parts Breakdown Parts ListModel VP11 Illustrated Parts BreakdownInternational Warranty Information

VP5A, VP11 specifications

Desa VP5A and VP11 are advanced digital conferencing systems designed for modern communication needs in various professional environments. These versatile units integrate cutting-edge technology to facilitate seamless audio and video interaction, making them ideal for corporate meetings, educational institutions, and collaborative workspaces.

One of the standout features of the Desa VP5A and VP11 is their high-definition video capabilities. With support for 1080p resolution, the systems deliver crystal-clear visuals, ensuring that every participant can be seen and heard with utmost clarity. This is complemented by advanced camera technology that includes autofocus and wide-angle lenses, allowing users to capture wide shots of larger groups without compromising on image quality.

Audio quality is another critical factor in effective communication, and the Desa systems do not disappoint. They incorporate noise-cancellation technology and high-fidelity microphones that capture sound effectively, minimizing background noise and enhancing voice clarity. This is especially beneficial in busy office environments or during conferences held in large rooms.

Connectivity is a cornerstone of the Desa VP5A and VP11 functionality. Both systems support a wide range of connection options, including USB, HDMI, and Bluetooth, making them compatible with various devices such as laptops, tablets, and smartphones. This flexibility allows users to easily integrate the systems into their existing infrastructure, facilitating a quicker setup and smoother operation.

Moreover, the user interface of the Desa VP5A and VP11 is intuitively designed for ease of use. Touchscreen controls make navigation straightforward, allowing users to manage video and audio settings, switch between devices, and initiate calls with just a few taps. This user-friendly approach significantly reduces the learning curve, enabling users to focus on the meeting rather than technical challenges.

Security features are also paramount in these systems, especially for businesses concerned about data privacy. The Desa units utilize encrypted connections for data transmission, ensuring that sensitive information remains secure during communication.

In summary, the Desa VP5A and VP11 conferencing systems stand out for their high-definition video, superior audio quality, versatile connectivity options, user-friendly interface, and robust security features. These characteristics make them excellent choices for organizations looking to enhance their communication capabilities and foster collaboration among remote and in-office teams.