Desa VN6D Lighting Instructions, To Select Heating Level, To Turn OFF GAS To Appliance

Page 11

OWNER’S MANUAL

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,

 

page 10, column 3.

2.

Make sure equipment shutoff valve

 

is fully open.

Piezo Ignitor Button

 

Control Knob

 

PILOT

OFF

 

 

IGNITOR LOW

HIGH

Figure 15 - Control Knob In The OFF Position (Model VN10A Shown)

Ignitor Electrode

ControlVN10A

KnobBurners

OFF

PILOT

LOW

OFF

PILOT

HIGH

3.

Turn control knob clockwise

 

to the OFF position.

4.

Wait five (5) minutes to clear out any

 

gas. Then smell for gas, including

 

near the floor. If you smell gas,

 

STOP! Follow “B” in the safety in-

 

formation, page 10, column 3. If you

 

don’t smell gas, go to the next step.

5.

Press in control knob, and turn coun-

Thermocouple

Pilot Burner

OFF

ControlVN6D

KnobBurner

OFF

PILOT

terclockwise

to pilot posi-

tion. Keep control knob pressed for

five seconds.

 

Note: You may be running this

heater for the first time after hook-

ing up to gas supply. If so, the con-

trol knob may need to be pressed in

for 30 seconds. This will allow air to

bleed from the gas system.

• If control knob does not pop up

when released, contact a qualified

service person or gas supplier for

repairs.

 

6. With control knob pressed in, push

down and release ignitor button. This

will light pilot. The pilot is attached to

the front of burner. If needed, keep

pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to

Troubleshooting, pages 13 through

15. Also contact a qualified service

person or gas supplier for repairs.

Until repairs are made, light pilot

with match. To light pilot with match,

see Manual Lighting Procedure.

7. Keep control knob pressed in for 10

seconds after lighting pilot. After 10

seconds, release control knob.

Note: If pilot goes out, repeat steps

3 through 7.

 

Figure 16 - Pilot

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW or HIGH locked positions (VN10A) or ON position (VN6D). Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

1.Slightly press in control knob and

turn counterclockwise to the LOW or HIGH positions (VN10A) or ON position (VN6D).

IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

ON

OFF

Figure 17 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 10 seconds after pilot is lit. After 10 sec- onds, release control knob.

5.Replace front panel.

104274

11

Image 11
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterVENT-FREE Natural GAS Heater Safety InformationUnpacking Productproduct IdentificationfeaturesSafety Pilot Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Installing Heater to WallRemoving Front Panel Of Heater Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Placing Heater On Mounting ScrewsGas Connection Connecting to GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions To Select Heating LevelInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingVENT-FREE Natural GAS Heater Gas leak. See Warning statement VN6D ODS/PILOT Parts ListIllustrated Parts Breakdown VN10A ODS/PILOT Service Publications Technical SpecificationsReplacement Parts Service Hints104274 International Warranty Information