Rheem 05EAUER, 07EAUER, 05NAUER, 07NAUER manual GAS Furnaces

Page 1

FORM NO. G11-449 REV. 6

Supersedes Form No. G11-449 Rev. 5

GAS FURNACES

RGLH- SERIES

Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW]

ENER

UIDE

Annual Fuel Utilization Efficiency - AFUE

THIS MODEL

80.0%

MID HIGH

 

 

 

 

 

 

 

 

78%

82%

88%

 

97%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRITERION® II

80.0-82.2% A.F.U.E.

DOWNFLOW GAS FURNACES

The Rheem® Criterion® II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA.

Features

Patented heat exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance.

Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment.

Left or right side gas and electric inlet connections with quick, simple change.

Direct Spark ignition models and integrated board with humidifier and electronic air cleaner hookups.

Insulated blower compartment helps to reduce jacket loss and noise.

Pre-paint galvanized steel cabinet.

Molded permanent filter.

Grab-holes in doors to aid in easy door removal and replacement.

A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Image 1
Contents GAS Furnaces Molded Permanent Filter Heat Exchanger Rheem Criterion II 80% Downflow GAS FurnaceModel IDENTIFICATION-DOWNFLOW Models Physical Data and SpecificationsModel Downflow DimensionsReduced Clearances IN. mm RglhModel Blower Motor Blower Performance DATA-DOWNFLOW Models935 441 910 429 885 418 855 404 825 389 785 370 760 359 USE with General Terms of Limited WarrantyFurnace Sizes Furnace Plenum Plenum Adapter CoilRheem Manufacturing Company Rheem AIR Conditioning Division