PREVENTATIVE MAINTENANCE SCHEDULE

WARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Item

Fuel tank

Filler neck screen

Fuel filter assembly (Fuel tank)

Fuel filter lines

Fuel filter (Pump)

Spark plug

Fan blades

Air passages around burner head

Motor

How Often

Flush every 150-200 hours of operation or as needed.

Check for trash when filling fuel tank. Clean when dirty.

Clean twice a heating season or replace as needed.

Check and tighten loose connections occasionally.

Clean fuel filter element every 250 hours.

Clean and regap every 300 hours of operation or replace as needed.

Clean each season or as needed.

Check each season for dirt and trash.

Not required, permanently lubricated.

How To

See Storage, page 9.

Lift out of fuel tank and rinse with clean kerosene.

See Fuel Filters, page 17.

See Fuel Lines, Page 16.

See Fuel Filters, page 17.

See Spark Plug, page 15.

See Fan Blades, page 14.

Remove dirt and trash with clean, soft cloth.

10

099565

Image 10
Contents High Pressure Portable Forced AIR Heater Contents Safety Information Carbon monoxide poisoning may lead to deathUnpacking Assembly Tools NeededWheel and Handle Assembly Theory OperationFuels Ventilation Fresh Air Opening RequirementsSafety Control Reset Button To Start HeaterTo Stop Heater Operation StorageTo Restart Heater How Often Preventative Maintenance ScheduleHow To TROUBLE- Shooting ProblemObserved Possible Cause Observed Problem Possible Cause Pump Pressure AdjustmentObserved Problem Possible Cause Remedy Upper Shell Removal Service ProceduresFan Blades Spark Plug NozzlePump Pump Pressure AdjustmentFuel Lines Fuel Filters Tank Fuel FilterWiring Diagram Accessory Burner Head Assembly Parts ListMotor and Pump Assembly Parts IllustratedBreakdown Parts List 099565 099565 Warranty and Repair Service Certificate of General Equipment Limited 90 DAY Warranty