Napco Security Technologies XP-600 manual HSystem Troubles, Beep with Y

Page 12

HSystem Troubles

The XP-600 is constantly monitoring its own components, as well as all critical services, such as AC Power and the Telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble does occur, it will caution you by lighting the yellow HSYSTEM light

and beeping the keypad buzzer. If you cannot immediately clear the system trouble, the system can still be used. Simply press Dto view the trouble as described below, and then arm the system.

In order to determine the nature of the trouble, press D, count the number of keypad beeps and ob-

serve the number of the illuminated zone light. Refer to the following table to determine the cause of the trouble. If there is more than one trouble to be viewed, pressing Dwill scroll to the next, and then exit

the HSYSTEM mode if there are no additional troubles to view.

 

Keypad Beeps or

Zone light

System Trouble

Action

 

 

ON

Condition

 

 

 

 

 

 

 

1 Beep with Y

1

AC Power Failure

This trouble will occur if AC power is not present. Make sure

 

flashes

 

 

system transformer is plugged into AC receptacle and check

 

 

 

circuit breaker, otherwise call installing company for service.

 

 

 

 

 

1 Beep

2

Low Battery

If there has been a recent power failure, the battery may be

 

 

 

 

partially depleted and must be recharged by the control panel.

 

 

 

 

If the trouble does not go away in 24 hours, call installing com-

 

 

 

 

pany for service.

 

1 Beep

3

Communication

The system was not able to report to central station. If this is

 

 

 

Failure

due to a temporary interruption in the telephone service, the

 

 

 

 

trouble can be cleared when the service is restored by press-

 

 

 

 

 

 

1 Beep

4

Telephone Line Cut

The telephone line has failed. If telephone service has been

 

 

 

 

temporarily interrupted, the trouble will clear it is when re-

 

 

 

 

stored. Otherwise, call installing company for service.

 

2 Beeps

1

Bell/Siren Trouble

There is a problem with the Bell or Siren. Call installing com-

12

 

 

 

pany for service.

 

 

 

 

Image 12
Contents XP-600 Introduction Table of Contents Important Test Your System WeeklyKeypad Controls and Indicators Arming Your System When Leaving Arming Your SystemEasy Arm Bypassing ZonesInstant Mode Protecting Yourself While at HomeEasy Exit optional Ambush Alarm Emergency ConditionsEmergency Buttons Disarming Your System / Silencing an Alarm Disarming Your System when ReturningAlarm Indication Silencing an AlarmFire Protection Preparing a Fire Escape PlanFamily Rehearsal Important! Read CarefullyFloor Plan A1Bell / Battery Test Special Functions aHSystem Troubles Beep with YHsystem Flashes Entering the User Program Mode Programming User CodesGlossary Napco Limited Warranty

XP-600 specifications

Napco Security Technologies, a leader in innovative security solutions, has made significant strides in enhancing the capabilities of modern security systems with their XP-600 control panel. Designed for both residential and commercial applications, the XP-600 offers advanced features and technologies that stand out in the realm of security management.

At the core of the XP-600 is its versatility. This control panel supports a wide range of security and life safety applications, allowing users to integrate various types of devices including burglary, fire, and environmental sensors. It is compatible with both wired and wireless devices, providing flexibility in system design while catering to specific security needs.

One of the key features of the XP-600 is its usability. The panel comes equipped with a user-friendly interface which includes a built-in 7-inch color touchscreen. This allows for easy navigation through the system’s settings, status updates, and configuration options. Additionally, the XP-600 offers voice prompts and customizable alerts, ensuring that users are informed and able to respond quickly to any situation.

The XP-600 leverages advanced communication technologies, including dual-path communication options. It supports both cellular and IP connectivity, ensuring that users receive real-time updates and alerts regardless of their location. Furthermore, the system is compatible with Napco’s proprietary Cloud services, enabling remote monitoring and management through a smartphone app, enhancing convenience and control.

Another standout characteristic of the XP-600 is its robust security protocols. With built-in encryption features, the system ensures that all communication between devices and the control panel is secure, protecting users from potential cybersecurity threats. Additionally, the panel’s event history logging provides a detailed account of system activity, allowing users to review and analyze security events over time.

Power management is also a notable aspect of the XP-600, as it includes features for energy conservation, ensuring that the system remains operational during power outages. The standby battery can provide long-lasting support, allowing an uninterrupted security monitoring experience.

In summary, the Napco Security Technologies XP-600 control panel embodies a blend of cutting-edge technology, ease of use, and robust security features. Whether for a small business or a large residential property, the XP-600 stands out as a reliable choice for anyone looking to enhance their security infrastructure, making it a valuable asset in today’s ever-evolving security landscape.