5($50('$'<

Keypad Controls and Indicators

 

6<67(0

Armed Light will light when system is Armed,

￿ Key Used to enable

Numerical Keys 1-9, 0. Used to enter

special functions and op-

User Codes, Zone numbers, etc.

and will flash when system is in Alarm

tions. Press ￿and then

 

 

the corresponding Spe-

 

 

cial Function number Op-

=21(￿

Ready Light will light when all zones are secure

tion (See Special Func-

 

 

and system is ready to be Armed.

tions, Page 10)

 

 

 

Bypass Key Used to

 

System Light will light and the Keypad

 

sounder will pulse to indicate that a system trou-

bypass zones. Press

 

 

ble is present.

Bypass and the corre-

 

 

(See System troubles, Page 12)

sponding zone number,

 

 

 

and then Arm system.

 

 

 

 

Zone Lights (1 through 4) will light to indicate

 

 

that the corresponding Zone is open, and will

Emergency Keys Press

NAPCO

flash to indicate a zone in alarm.

 

 

simultaneously to signal

 

 

an emergency condition.

 

 

Press $+$ for

Key Press to display any present

 

Auxiliary Emergency or

￿Key - (Reset) used to clear miss-entered

3+3for Police Emer-

System troubles. Only available when

codes, reset Alarm Memory, etc..

gency. (Programmable)

System Light is lit.

(See System troubles, Page 12)

 

 

 

5

Oi220a

Tuesday, September 16, 1997 08:30

page 5

 

Image 5
Contents $5=2150$6670 Oi220a Introduction Important Test Your System Weekly Table of Contents$50$ Keypad Controls and IndicatorsArming Your System Arming Your System When LeavingEasy Arm Bypassing ZonesEasy Exit optional Instant ModeProtecting Yourself While at Home Emergency Buttons Ambush AlarmEmergency Conditions Disarming Your System when Returning Disarming Your System / Silencing an AlarmAlarm Indication Silencing an AlarmSpecial Functions Easy Arm when system is disarmedProgramming User Codes Entering the User Program ModeSystem Flashes 9System TroublesFire Glossary Oi220a Napco Limited Warranty
Related manuals
Manual 28 pages 54.33 Kb

XP-400 specifications

Napco Security Technologies has established itself as a leading name in the field of security solutions, and one of its standout products is the XP-400, a cutting-edge alarm panel designed for modern security applications.

The Napco XP-400 is recognized for its robust performance and versatility, making it suitable for both residential and commercial security systems. At the heart of its design is an advanced microprocessor that ensures seamless operation and efficient processing of security signals. This intelligent technology allows for faster response times and greater reliability compared to traditional panels.

One of the main features of the XP-400 is its ability to support a wide array of devices. It can accommodate a variety of sensors, keypads, and other peripherals, enabling users to customize their security systems to meet specific needs. The panel supports both hardwired and wireless devices, providing flexibility in installation and enhancing the overall adaptability of the security system.

Security is further enhanced through the XP-400's integration with Napco's proprietary technologies. The panel features built-in alarm verification, which significantly reduces false alarms by allowing for the confirmation of intrusion events before dispatching emergency services. This feature is critical for maintaining a good relationship with local authorities and ensures efficient utilization of resources.

Moreover, the XP-400 utilizes advanced communication technologies, supporting various forms of connectivity, including phone line, cellular, and internet-based connections. This multi-faceted communication strategy ensures that alerts and notifications are promptly delivered to users and monitoring centers, regardless of the circumstances.

In terms of user interface, the XP-400 is designed with ease of use in mind. The panel includes user-friendly keypads that allow for straightforward operation, programming, and user management. The intuitive layout ensures that even those with limited technical knowledge can navigate and manage their security system effectively.

Another notable characteristic of the XP-400 is its scalability. As security needs evolve, the panel can be expanded with additional zones and features, ensuring long-term viability and protection for its users. This scalability not only extends the life of the investment but also allows for future upgrades in response to changing security technologies and threat landscapes.

In conclusion, the Napco Security Technologies XP-400 stands out as a reliable and versatile security solution. With its advanced microprocessor, comprehensive device support, alarm verification, and flexible communication capabilities, it remains an excellent choice for those looking to enhance their security infrastructure. Its user-friendly design and scalability further solidify its reputation as a top-tier security panel on the market.