Monessen Hearth HWB700HB manual Chimney CAP Installation

Page 18

CHIMNEY CAP INSTALLATION

MODEL LC CHIMNEY CAP

SPECIAL NOTE: The proper height as previously explained is important to assure proper draft and safety. The chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney. The chimney should not be extended more than 90 inches above the supporting roof structure without additional support. In the case of an “A” frame type construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a support should be attached to the chimney at the 90 inch level that is strong enough to support a wind load of 3-1/8 pounds for each inch the chimney extends above 90 inches. The flue outlet must be a minimum of three feet above the point where in penetrates the roof.

CAUTION: Be careful to avoid electrical shock hazard when contacting wires to the metal chimney components.

1.Extend the regular chimney sections until the top of the chimney is 4 inches below the total flue height desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed.

2.Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of the flashing under the shingles.

3.Set the flashing on the roof. Hold a section of the outside pipe (13" diameter) on the flashing and scribe a line around the flashing, then cut the top off the flashing by cutting 1/4 inch below the scribed line. This should increase the diameter of the flashing outlet sufficiently to allow the flashing to be placed over the chimney. See Figure 19.

4.Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the chimney to assure that the proper minimum clearances are maintained.

5.Nail the flashing securely in place with eight nails.

6.Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess mastic at this area to be used in step eight. NOTE: Use pliers and wear gloves when performing step seven to minimize the danger of cutting your hands on the edge of the storm collar.

7.Place the storm collar around the chimney and put the collar together like a belt in belt loops. Slide the end of collar under the two loops on the other end with the loops facing up. Overlap the ends of the collar until it is tight against the chimney. Bend the free end of the collar back over the loops to hold the storm collar securely together. The excess end of the storm collar may be trimmed off.

8.Slide the storm collar down snugly against the flashing until the excess mastic left in step six is forced up into the crack between the storm collar and the chimney. This should make the joint between the flashing and the chimney watertight.

9.Install the chimney cap by placing the cap into matching parts of the last chimney section. Then punch or drill 1/8 inch diameter holes in the inlet air duct (chimney pipe) where specified on the brackets and fasten it down with the No. 8 screws provided. Do not penetrate the inner stainless steel pipe while installing the screws.

10.Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts have been damaged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney cap has a rust protective coating but the cut edges of the parts are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney cap should be detergent washed and painted with a galvanized primer paint.

17

53D9036. Rev 1 03/03

Image 18
Contents HWB700/HWB700HB Models Table of Contents CongratulationsImportant Information Intended Product UsageOperation Guidelines Residential Installation ClearancesSeries Chimney Sections Fireplace Location Installation Preparation Single Story Installation with Attic Space Floor Protection Metal Safety Strip Combustible Floor Fireplace Components Fireplace Installation Chimney Installation Minimum Required Roof Opening Chimney Offset Installation Chimney Offset and CAP Installation Centerline 30˚ ChimneyChimney CAP Installation Chimney Height and Offset Charts Intermediate Height Sections InchesChimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations Installation Above Basement Or Crawl SpaceOutside Combustion AIR Recommendations Combustion AIR Assembly GAS Appliance Installation Applying Decorative Trim to the Fireplace Trim and Door Installation Mantel Inst AllationFireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Parts Diagram and List Parts Diagram and List Limited Warranty Except BlowersYour Duties Appliance Installer

HWB700HB specifications

The Monessen Hearth HWB700HB is a premier heating appliance that embodies both functionality and aesthetic appeal. Designed to provide efficient warmth during cold weather, this unit showcases an impressive array of features and technologies that make it a standout choice for homeowners.

One of the most notable characteristics of the HWB700HB is its powerful heating capability. With a heat output of up to 33,000 BTUs, this unit can efficiently heat an area of up to 1,400 square feet, making it ideal for larger living spaces. The fireplace operates on natural gas or propane, providing flexibility in fuel choice and installation options.

The HWB700HB is equipped with a sophisticated burner system that utilizes Monessen's patented technology. This burner system creates realistic, natural-looking flames that enhance the overall ambiance of any room. The adjustable flame height feature allows users to customize the flame intensity to suit their mood and needs. This attention to detail in flame presentation sets the HWB700HB apart from traditional heating sources.

In addition to its aesthetic features, the Monessen Hearth HWB700HB is designed with efficiency in mind. It boasts a high-efficiency rating, ensuring that more heat is delivered to the room rather than escaping through the chimney. This results in lower energy costs and less environmental impact over time. The unit is also equipped with a variable speed blower, which helps to circulate warm air throughout the space more effectively.

Safety is another key aspect of the HWB700HB design. It features a reinforced steel construction for durability and a built-in safety shut-off feature that provides peace of mind. The glass doors are made from high-temperature ceramic material, allowing for a clear view of the flames while ensuring safe operation.

The Monessen Hearth HWB700HB also offers design flexibility. It can be seamlessly integrated into various home styles with its traditional or contemporary faceplate options. Whether you're looking to create a cozy ambiance in a rustic cabin or a sleek modern living space, the HWB700HB can meet your design needs.

Overall, the Monessen Hearth HWB700HB is a versatile and efficient heating solution that combines modern technology with traditional charm. Its powerful heating capacity, realistic flame presentation, energy efficiency, and thoughtful safety features make it an excellent choice for homeowners looking to enhance their living spaces.