Monessen Hearth GLCF36, GSTF36 Optional Accessories & Specifications, Product Specifications

Page 4

OPTIONAL ACCESSORIES & SPECIFICATIONS

Product Specifications

Model

 

Width

Height

Depth

Minimum Hearth Area

Hearth

Radiant or

Design

 

 

 

 

 

 

 

 

 

 

Opening

Circulating

Certified

Actual

Framing

Actual

Framing

Actual

Framing

A

B

C

 

 

(Sq. In.)

 

 

GSTF36

39-1/2"

40"

37-3/4"

38"

23-3/4"

22-1/2"

36"

20-1/4"

21-1/2"

774

Both

CSA

GPF36

 

39-1/2"

39"

37-3/4"

38"

23-3/4"

22-1/2"

36"

20-1/4"

21-1/2"

774

Both

CSA

G(R/L)CF36

 

39-1/2"

39"

37-3/4"

38"

23-3/4"

23-1/8"

36"

20-1/4"

21-1/2"

774

Circulating

CSA

OPTIONAL ACCESSORIES

 

 

Minimum Hearth Area

 

 

Brass Louvers

Pewter Louvers

Brass Hood

Variable Thermostat

 

 

 

Controlled Forced Air Blower

Decorative arched fronts, frames, firescreen doors and filigree available in gold tone, brushed pewter and black (GSTF36 Only)

GAS LOGS ACCESSORIES

Decorative Fiber Ceramic Embers and Cinders

Extra Volcanic Rock

Stainless Steel Flexible Gas Connector

Damper Clamps

Note: Please see Product

Specification Chart above.

C

B

A

Gas Log Minimum Hearth Area (refer to drawing)

A

B

C

DST Gas Logs 36"

20-1/4

21-1/2"

For Remote Operation:

On/Off Hand-Held

On/Off Hand-Held

On/Off Thermostat

Hand-Held

Remote Control

Remote Control with

Hand-Held

Programmable

with Receiver.

90 min. countdown

Remote Control

Thermostat

 

 

timer with Receiver.

with Receiver.

Remote Control

 

 

 

 

with Receiver.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional Gas Log Product Specifications

 

 

 

 

Approx.

Approx. Cost

 

Log

Fuel

 

Heating

to Operate*

Model

Millivolt

Area

Per Hour

Size

Type

Control

(Sq. Ft.)

(Low-High)

DST30NV

30"

NG

24,000-38,000

1,300

24¢-38¢

DST30PV

30"

LP

31,000-38,000

1,300

31¢-38¢

*Based on 2003 Dept. of Energy National Average Energy Cost for low- est and highest Btu operation.

On/Off Thermostat

Touch Light™ Table

Programmable

Hand-Held Remote

Top/Wall Mount TLM

Wireless Wall

Control with 3-Speed

On/Off and TLT

Thermostat with

Blower Control with

Thermostat Remote

receiver.

Receiver.

Control with Receiver.

 

REGULATORY APPROVAL

The DST series of vent free gas logs have been tested and approved by CSA as an unvented room heater to the latest ANSI Z21.11 and I.A.S. US5-95 require- ments. These units also comply with ANSI Z21.60-1991 “Decorative Gas Appliances” for solid-fuel burning fireplaces. These gas logs are intended for

A

D

C

B2 B

C2

Vent Free Fireplace

Framing Dimensions

 

GSTF36

GPF36

G(R/L)CF

A

19"

19"

21"

B

22-1/2"

22-3/4"

B2

23-1/8"

C

40"

C2

39"

39"

D

38"

38"

38"

 

 

 

 

Please refer to the installation manual for more detailed framing instructions.

installation into solid-fuel burning fireplaces, or CSA approved unvented fire- places and are also approved for installation in an aftermarket manufactured (mobile) home, where not prohibited by state or local codes.

The Designer Series fireboxes have been tested and approved to the Z21-91 standard for ventless firebox enclosures.

149 Cleveland Drive • Paris, Kentucky 40361

www.monessenhearth.com

To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice.

© 2006 Monessen Hearth Systems, Inc.

Warning:

It is recommended that the screen be used during operation of this log set. Always ensure the screen has adequate spaces to allow for passage of combustion air to the gas log set.

Correct installation of the ceramic fiber logs, proper location of the heater and periodic cleaning are necessary to avoid potential service problems with sooting.

Keep small children and animals away from the open flame of the gas log set at all times.

There may be a start-up odor associated with the heating of the logs. The odor should diminish in 2-3 hours of operation with the burner at its highest setting with the fan in the off position.

Sold by:

MADE IN U.S.A.

VFDesigner-MHS4506

Rev. 04-06

Image 4