Monessen Hearth DIS33G manual Important Safety Information, Installer, Owner

Page 3

IMPORTANT SAFETY INFORMATION

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

IMPORTANT

Read these instructions carefully before installing or trying to operate this vent-free gas heater.

WARNING

Any change to this heater or its controls can be dangerous.

Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

Do not allow fans to blow directly into the fireplace. Avoid drafts that alter burner flame patterns.

Do not use a blower insert, heat exchanger insert or other accessory, not approved for use with this heater where applicable.

1.Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

2.Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.

3.Young children should be carefully supervised when they are in the same room with the appliance.

4.Do not place clothing or other flammable material on or near the appliance.

5.Any safety screen or guard removed for servicing an appliance, must be replaced prior to operating the heater.

6.Installation and repair should be done by a quali- fied service person.

7.To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at least annually by a professional service person. More fre- quent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.

8.CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater ser- viced as it may not be operating properly.

9.The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas

Code, ANSI Z223.l/NFPA54.

10.This unit complies with ANSI Z21.11. Unvented Heat- ers.

11.Do not install the heaters in a bathroom or bedroom.

12.Correct installation of the ceramic fiber logs, proper location of the heater, and annual cleaning are neces- sary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See log place- ment instructions for proper installation.

13.Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.

14.Caution: Candles, incense, oil lamps, etc. produce com- bustion byproducts including soot. Vent-free appliances will not filter or clean soot produced by these types of products. In addition, the smoke and/or aromatics (scents) may be reburnt in the vent-free appliance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appli- ance is in operation.

15.This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be pro- vided. See page 9.

Continued on page 4

23D8020

3

Image 3
Contents Model DIS33G What to do if YOU Smell GASRead and Save These Instructions Contents Important Safety Information InstallerOwner Never connect unit to private non Operation Product FeaturesProduct Features and Specifications Natural GASPROPANE/LPG What YOU will Need for Installation Getting StartedMake Sure YOU have Received ALL Parts General Installation Information Installing CanopyRemoving Screen Adequate Combustion and Ventilation AIR CodesBTU/Hr = 15 1/ 2 x 12 x 1000 = 29760 BTU/Hr Clearances and Height Requirements Before Installing the Fireplace InsertClearances and Height Requirements Minimum Clearance above Combustible Flooring Fireplace Framing Outer Wall InstallationSecuring Heater to Floor Removing Grate and Base AssemblyConnecting the GAS Access Holes Millivolt Control Figure Checking GAS PressureElectrical Wiring MILLI-VOLT Connecting Optional Wall Switch or ThermostatThat does not Require 110 VAC to Operate Complete Millivolt System Check Checking System OperationWhite Electrical Wiring FANInstalling Charred Timber Logs on Burner LOG PlacementInstalling Left Base Log #3 Installing Left Top Log #5 Placing Rock Wool Installing Right Top Log #6Flame Appearance Checking the Pilot FlameThermostat and MILLI-VOLT Control Operating Instructions Checking the Burner FlameOperating Instructions For Your Safety Read Before LightingMILLI-VOLT/THERMOSTAT Control Lighting Instructions Operating Instructions and Blower Operation Match Lighting InstructionsCleaning and Servicing Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame Illustrated Parts Breakdown DIS33N/P Replacement Parts ListIllustrated Parts Breakdown Replacement Parts are Available Through Your Retailer CTCL18 Charred Timber Logs23D8020 Basic Warranty Five Year Warranty
Related manuals
Manual 1 pages 56.1 Kb

DIS33G specifications

The Monessen Hearth DIS33G is a remarkable direct vent gas fireplace designed to provide both warmth and aesthetic appeal. Known for its versatility and advanced features, this fireplace is perfect for modern living spaces, enhancing comfort while being energy-efficient.

One of the standout features of the DIS33G is its sleek design that fits seamlessly into a variety of home decors. With a compact size of 33 inches, it can be installed in smaller spaces without compromising on style or functionality. The unit boasts a large viewing area, which is framed by a beautiful glass front, allowing occupants to enjoy the mesmerizing flames from various angles.

The DIS33G employs advanced technologies for superior performance. It is equipped with a powerful, efficient heating system that can produce up to 30,000 BTUs. This allows for ample heating capacity, making it ideal for creating a cozy atmosphere in larger rooms or open-concept spaces. Notably, its direct vent technology ensures that all combustion gases are expelled outdoors while drawing in fresh air for combustion, promoting healthier indoor air quality.

Another key characteristic is the variety of customizable options available, including multiple log sets and decorative media choices. Homeowners can choose between traditional log sets or contemporary glass media to create the desired ambiance. Additionally, the unit offers various finish options, enabling users to blend the fireplace seamlessly into their home's interior.

The Monessen Hearth DIS33G is also designed for user convenience. It comes with an easy-to-use remote control system, allowing users to adjust flame height and heat output without leaving their seats. The unit includes a thermostat, providing automatic temperature regulation for enhanced comfort and energy efficiency.

Safety is paramount with the DIS33G, as it comes with built-in safety features, including a safety shut-off system that automatically engages in case of irregular operation. This ensures peace of mind for those using the fireplace.

In summary, the Monessen Hearth DIS33G stands out as an ideal solution for those seeking a stylish and efficient gas fireplace. With its modern design, advanced heating technology, customizable options, and safety features, it provides both functionality and elegance, making it a valuable addition to any home. Whether for warmth or aesthetic charm, the DIS33G is designed to transform any living space into a cozy retreat.